Results 1 to 20 of 85 for “"Sensor interface"”
-
Electrochemical sensor interface
… have led to the development of electrochemical sensors that utilize electrodes with a width of one micron or less. This increased sensitivity has opened up a range of new electrochemical sensing applications, allowing the technology to move beyond the confines of the laboratory and into …
-
Universal Voltage Rate Sensor Interface
… involves developing a universal voltage rate sensor interface that minimizes these effects and also improves the signal-to-noise ratio. This is based on the concept of amplitude modulating the temperature data and differentiating it at a higher frequency. The proposed concept of improvement in …
-
A sensor interface system for digital radiosondes
… a pulse modulated transmitter and more accurate sensors. This thesis proposes a method of combining the two into a workable radiosonde. Solid-state technology is used throughout including MOS integrated circuits, linear integrated circuits, and a silicon pressure transducer. System tests …
-
MULTI-CHANNEL CDMA-LIKE CAPACITIVE SENSOR INTERFACE CIRCUITS
… is governed by three components, i.e. advanced sensors, low-power and low-cost sensor interface circuits and efficient wireless connections. This thesis introduces a CDMA-like period modulation multi-capacitive-sensor interface circuit, which targets at the IoT applications. The proposed …
-
Design and of eldertech health monitoring sensor interface
Motion, bed, and gait analysis sensors are installed in the homes of seniors and monitored continuously for the purpose of detecting early signs of health change as well as functional decline. Automated health alerts are distributed to clinical staff as part of a clinical decision support system. …
-
Integrated Time-based Sensor Interface Circuits for Implant Applications
… thesis is the design of integrated time-based sensor interface circuits for implant applications, targeted towards monitoring of neurochemical and neuroelectrical signals. The thesis and related publications (I - VI) describe the investigated and implemented circuits. First, a sensor interface …
-
The design of sensor interface circuits for electrochemical impedance spectroscopy
… RC-based equivalent AC impedance electrochemical sensor models, namely, models consisting of a resistor and a capacitor in parallel structure, cannot accurately reflect realistic sensor behavior; therefore, they do not support essential simulation analyses (e.g., transient, DC sweep, or DC …
-
A Non-Contact Sensor Interface for High-Temperature, MEMS Capacitive Sensors
… work presents a high-temperature non-contact sensor interface design for MEMS capacitive sensors. The sensors are proposed for an active fuel emission control (AFEC) system that incorporates a smart fuel injector, and must operate in a very harsh and corrosive environment. It is reasoned that …
-
LOW- VOLTAGE HIGH EFFICIENCY ANALOG-TO-DIGITAL CONVERTER FOR BIOMEDICAL SENSOR INTERFACE
… high-efficiency ADC dedicated for biomedical sensor interface. An energy-efficient dual-capacitive-array architecture for successive approximation (SA) ADC is proposed. Unlike conventional topologies, the proposed architecture utilizes two capacitive arrays for quantization to reduce the …
-
LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION
Bio-potential sensing plays a critical role in extracting real-time ExG signals and facilitating the diagnosis and treatment of diseases such as seizure and cardiovascular abnormalities. The design of low-power and low-noise ExG sensing SoCs in a wearable form factor is essential. The proposed …
-
Characterizing the Influence of the Textile-Sensor Interface on Stitched Sensor Performance
Textile-based strain sensors are first defined with examples of various sensing mechanisms and applications, focusing on on-body smart garments for biomonitoring. A current lack of research in the textile substrate influence on sensor performance is noted, with a thesis investigation outlined to …
-
Low power low noise analog front-end IC design for biomedical sensor interface
… low-noise analog front-end ICs for biomedical sensor interface. A cross-domain optimization technique that balances the power consumption between analog and digital blocks was explored. The technique was applied to the design of several sensor interface chips, which include a 445nW fully …
-
Design and implementation of ultra-low-power sensor interface circuits for ECG acquisition
… and implementation of ultra-low-power biomedical sensor interface circuits that are suitable for telemetric medical applications and in particular for wearable ECG devices. It is motivated by the increasing awareness and demand in pervasive and remote personal healthcare services due to population …
-
A Low Cost Wireless Sensor Interface for the Quantification of Tremor in Parkinson’s Disease
… system in detail and study the correlation of sensor readings with UPDRS scores in the different DBS states. In particular, we provide data showing that such a system can be used for the objective quantification of tremor symptoms in PD patients.
-
Resonance Frequency Bifurcation Based Passive Wireless Sensor Interface Design For Multi-Parameters And Differentially Monitoring
Many wireless and passive sensors are developed and used in various fields with the growth of Internet-of-Things, IoT, and biomedical technologies. These sensors can measure physical parameters such as temperature, pressure, displacement, etc. These parameters can be converted into corresponding …
-
Design techniques for ultra-low-power sensor interface circuits and systems in nano-scale CMOS technologies
… further enhances its growth. Autonomous wireless sensors and their networks have been one of the most prevailing and important research topics for the past decades. Although researchers have been pushing the state-of-the-art of sensor readout to have higher and higher power and area efficiency, …
-
Noise Analysis and Measurement of Integrator-based Sensor Interface Circuits for Fluorescence Detection in Lab-on-a-chip Applications
Lab-on-a-chip (LOC) biological assays have the potential to fundamentally reform healthcare. The move away from centralized facilities to Point-of-Care (POC) testing of biological assays would improve the speed and accuracy of these, thereby improving patient care. Before LOC can be realized, a …
-
Design and Optimization of Sensor Interface Circuitry and All-Digital PLL in 22nm Technology with gm/ID Methodology Using Precalculated Look-Up Tables.
… is the massive parasitic capacitance of the sensor (approx. 5 pF), which severely limits the bandwidth required to detect rapid, picoampere-level ion currents. Additionally, designing high-performance analog interfaces in deep-submicron nodes using traditional, iterative SPICE simulations is …
-
Signal Compression Methods for a Wear Debris Sensor
This thesis develops a debris sensor interface to perform real-time continuoustransmission of data from a sensor to monitor debris particles in oil. A test setup is created in which data from a single wear debris sensor is transmitted by the implemented debris sensor interface to a personal …