Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"Separation Columns"”.
-
Portable Micro-Gas Chromatography with Multidimensional Compound Identification Analysis
… versatile and powerful tool to perform complex separations. However, these systems come with the cost of being bulky and requiring a high amount of power for operation. With considerable research for over 40 years, the advent of Micro-Gas Chromatography (µGC) made it possible for miniaturized, …
-
Density Modulated Semi-Packed Micro Gas Chromatography Columns
… requirements of previously reported semi-packed columns causes a significant sacrifice in separation efficiency. This thesis covers the techniques for evaluating the separation column in a gas chromatography system as well as the important parameters that have the most effect on a column’s …
-
Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection
… extracts by ion exclusion and ion exchange separation followed by amperometric detection. Optimum eluant compositions and separation columns for the best separation have been determined, as well as the optimum working electrode, electrolytes, and applied potentials for the best detection. An …
-
Experimental and Theoretical Analyses of Adiabatic Two-phase Flows in Horizontal Feed Pipes
The majority of technical separation processes for fluid mixtures utilize the principle of rectification. If a two-phase mixture is fed into the column, possibly undesirable flow morphologies or severe droplet carry-over may occur, which detrimentally affect separation efficiency and equipment …
-
A Fast-Response Odor Chromatographic Sniffer (FOX)
… stationary phase coatings for microfabricated columns, achieving up to 8300 theoretical plates per meter for naphthalene using 1-butylpyridinum bis(trifluoromethylsulfonyl)imide [BPY][NTf2] at 240°C. The development of portable systems for fuel adulteration detection is demonstrated, capable of …
-
PID Auto-Tuning and Control System for Heaters in μGC Systems
… for the micro-fabricated preconcentrators and separation columns used since temperature changes directly affect retention time. Proportional Integral and Derivative (PID) controllers provide reliable temperature control and can be tuned to obtain the desired response. The conventional method of …
-
Microfluidic Columns with Nanotechnology-Enabled Stationary Phases for Gas Chromatography
… of key GC components (preconcentrator, separation column, detector, and pumps) using micro- and nanotechnology based techniques is an on-going research field. This dissertation specifically deals with the design, fabrication, coating, and chromatographic testing of microfabricated …
-
The Application of Thin Film Ionic Self-assembled Multilayer (ISAM) Nanostructures in Electromechanical Bending Actuators and Micro-fabricated Gas Chromatography (uGC) Devices
… thermal preconcentrators (microTPC) and separation columns (microSC) as adsorbent and stationary phase materials, respectively. New fabrication approaches were developed to selectively coat uniform conformal ISAM SNP coatings in these devices with different 3D microstructures. Thus, …
-
MEMS-Based Micro Gas Chromatography: Design, Fabrication and Characterization
… performance MEMS-based micro gas chromatography columns having wide range of applications in the pharmaceutical industry, environmental monitoring, petroleum distillation, clinical chemistry, and food processing. The first part of this work describes different approaches to achieve …
-
Capillary-based microanalytical systems
… The advantages of moving from conventional size columns into the capillary domain include higher efficiencies, better mass limits of detection, low reagent consumption, and a small sample requirement. Optical absorption detection is the most common detection mode in capillary-based separation …
-
Development of Isoelectric Focusing Techniques for Protein Analyses
… focusing (IEF) is a powerful approach in separations of zwitterionic substances such as proteins, peptides and amino acids. It is important in proteomic research. Generally, in IEF, carrier ampholytes (CAs) are necessary to establish a stable pH gradient. However, CAs also bring attendant …
-
Optimization of Mass Spectrometry-Based Methods for Low-Input and Spatial Proteomics
… processing platform called nanoPOTS, reduced separation columns' inner diameter to increase ionization efficiency and concentrate analytes for mass spectrometers and optimized data acquisition modes for increasing proteome coverage in spatial and single-cell proteomics and applying these …
-
Flow Through, 2D/3D Nanoplatelet Supports for Packed Beds and Columns
… playing an increasing role in many reactions and separations. The dispersion in packed bed reactors and separation columns can be reduced by the development of new packing structures having open and connected pore geometries. The application of new materials in High Performance Liquid …
-
“The Sweet Smell of Chemistry” - Characterization of volatile mixtures from Life Sciences
From a Separation Science standpoint, Life Sciences represent a broad source of complex compound mixtures that require powerful analytical strategies to be considered when characterization is aimed. The depiction of the complex volatile organic compound (VOC) component of these mixtures is an …
-
Semi-Packed Micro Gas Chromatography Columns
Separation of complex gaseous mixtures using gas chromatography (GC) is an important step in analytical systems for environmental monitoring, medical diagnosis, and forensic science. Due to its high resolving power, analysis speed, and small sample size, GC, has become the premier technique for …