Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 37 for “"Sequence Components"”.

  1. Sequence Components Based Detection and Classification of Faults in an Islanded Distribution System with 100% Inverter Based Resources

    … an issue due to lack of negative and zero sequence currents and severely restricted positive sequence fault currents contributed by IBRs. This issue is most prominent in an islanded distribution system fed completely by IBRs. Recognizing that even in such an island where sequence currents …

    clemson Repository record for Sequence Components Based Detection and Classification of Faults in an Islanded Distribution System with 100% Inverter Based Resources (opens in a new tab)

  2. Balancing Asymmetrical Load Using a Static Var Compensator

    … enhances the amount of unbalance or negative sequence components. Alongside asymmetrical load, further increase in negative sequence components is introduced due to the network inherent asymmetry i.e. untransposed transmission. Thus, they are usually excessive and exceeds standards at weak …

    chalmers Repository record for Balancing Asymmetrical Load Using a Static Var Compensator (opens in a new tab)

  3. Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems

    … motor current spectrum analysis (MCSA), negative sequence components analysis utilizing a symmetrical components transformation, and the space-vector pendulous oscillation method. The applicability of these diagnosis techniques to this case-study experimental interior permanent- magnet machine …

    marquette Repository record for Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems (opens in a new tab)

  4. Negative sequence impedance measurement for distributed generator islanding detection

    … generator networks by measuring negative sequence impedance differences between islanded and utility connections. Extensive testing was conducted on a commercial building and 25 kV distributed generator fed network by measuring naturally occurring and artificially injected negative …

    ubc Repository record for Negative sequence impedance measurement for distributed generator islanding detection (opens in a new tab) Download PDF for Negative sequence impedance measurement for distributed generator islanding detection (opens in a new tab)

  5. Epstein-Barr virus and cellular DNA damage response

    … for the virus to efficiently conserve its DNA sequence. Components of the double strand break homologous repair pathway are known to be recruited to viral replication compartments and loaded onto viral DNA to achieve efficient and faithful replication of the viral DNA. Using an epithelial cell …

    birmingham Download PDF for Epstein-Barr virus and cellular DNA damage response (opens in a new tab)

  6. Proteção diferencial do DFIG com separação de componentes de sequência do estator e do rotor

    … stability of the system and protection of its components. Differential protection is used in many components of electrical systems and for wind turbines based on DFIG this protection was recently proposed. Therefore, this work proposes a new DFIG differential protection scheme using the current …

    brazil-ufrn Repository record for Proteção diferencial do DFIG com separação de componentes de sequência do estator e do rotor (opens in a new tab)

  7. Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors

    … Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor's operating state. By fine-tuning pre-trained CNNs on these image …

    sask Repository record for Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors (opens in a new tab)

  8. RISK ASSESSMENT OF THE NOVEL MINI-SYNPLASTOME AND CONVENTIONAL CHLOROPLAST TRANSFORMATION GENETIC TOOLS IN AGRICULTURE

    … evaluation of risks associated with sequence components of the mini-synplastome (origin of replications and regulatory elements), optimized versions of the mini-synplastome with no residual activity in bacteria have been designed. This study represents a valuable resource for …

    ut-knoxville Repository record for RISK ASSESSMENT OF THE NOVEL MINI-SYNPLASTOME AND CONVENTIONAL CHLOROPLAST TRANSFORMATION GENETIC TOOLS IN AGRICULTURE (opens in a new tab)

  9. Impact of Inverter-Based Resources on Grid Dynamics

    … It is found that inverters can act as negative-sequence sources to inject negative-sequence currents into the grid during the grid restoration period and thus can adversely impact the performance of protection schemes based on negative sequence components and potentially cause relay …

    ndsu Repository record for Impact of Inverter-Based Resources on Grid Dynamics (opens in a new tab)

  10. Addressing the Performance of Distance Relays in Presence of Inverter Based Resources

    … focuses on the impact of inverters on negative sequence component-based directional elements that assist distance relays in identifying the direction of fault current, causing incorrect tripping of relays and missing out on in-zone faults. The main reasons for these misoperations are the …

    clemson Repository record for Addressing the Performance of Distance Relays in Presence of Inverter Based Resources (opens in a new tab)

  11. Transmission Line Voltage Sequence Component Based Differential Protection Algorithm Under High Penetration of Inverter Based Resources

    … The proposed solution uses the voltage sequence components based differential protection algorithm for lines to accurately indicate fault occurrences and isolate the affected protected line in networks that have a significant proportion of the new inverter based resources alongside …

    auckland-ms Repository record for Transmission Line Voltage Sequence Component Based Differential Protection Algorithm Under High Penetration of Inverter Based Resources (opens in a new tab)

  12. Real time voltage stability monitoring by Thevenin impedance estimation with local measurement

    … by taking advantage of the existance of negative sequence components in the system. The concept of this method has been proved mathematically. Simulations were performed on simple systems and on the modified IEEE 13 bus power flow test case to verify the feasibility of the method and the results …

    ubc Repository record for Real time voltage stability monitoring by Thevenin impedance estimation with local measurement (opens in a new tab) Download PDF for Real time voltage stability monitoring by Thevenin impedance estimation with local measurement (opens in a new tab)

  13. Matrix converter application to FACTS and embedded generation

    … Extraction of the positive and negative sequence components is essential in obtaining non-oscillatory output power, and a dual current controller is used to this end.

    strathclyde Repository record for Matrix converter application to FACTS and embedded generation (opens in a new tab)

  14. cis-Regulation in the Mammalian Rod Photoreceptor

    … The goal of my thesis research is to define the sequence components of CREs that determine transcriptional output. In order to accomplish this goal, I developed a method to measure the regulatory activity of thousands of CREs in a single experiment. In this method I insert unique barcodes in the …

    wustl Repository record for cis-Regulation in the Mammalian Rod Photoreceptor (opens in a new tab)

  15. Reduced Reference Frame for AC Systems

    … machines, the decomposition into symmetrical sequence components using the Fortescue transformation for the study of asymmetrical short circuits, and the use of the Clarke transformation for the control of power converters are good examples where the use of an appropriate reference system is …

    sevilla Repository record for Reduced Reference Frame for AC Systems (opens in a new tab)

  16. Accurate fault location for power transmission lines

    … the eigenvalues can simply be evaluated from the sequence components and a real eigenvector matrix can be defined for all the lines. For untransposed lines the new algorithm maintains its high accuracy when assuming perfect transposition to simplify the evaluation of eigenvalues and eigenvectors. …

    city-london Download PDF for Accurate fault location for power transmission lines (opens in a new tab)

  17. Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors

    … units (D-PMUs) and the phase angle of sequence impedances. The methodologies are tested against a variety of islanding and non-islanding events on both smaller and larger microgrid systems. For the analysis, modeling of D-PMUs and microgrid systems is carried out in the PSCAD™/EMTDC™ …

    sask Repository record for Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors (opens in a new tab)

  18. Monitoring and Control for Fault Ride-Through of Power grids and Microgrids using Phasor Estimator of Symmetrical Components

    … the electrical grid and foresee unsymmetrical components in the occurrence of faults. This research steers towards improving fault detection and taking the required control strategies to suppress the unsymmetrical components in the power system, implementing the positive, negative, and zero …

    ttu Repository record for Monitoring and Control for Fault Ride-Through of Power grids and Microgrids using Phasor Estimator of Symmetrical Components (opens in a new tab)

  19. Design and analysis of a new model predictive current controller for grid connected converters

    … is used to extract the positive and negative sequence components and a new calculation time compensation technique is proposed, which offers superior accuracy to existing approaches. The system stability is verified theoretically. Simulation and experimental results are included to prove the …

    strathclyde Repository record for Design and analysis of a new model predictive current controller for grid connected converters (opens in a new tab)

Page 1 of 2