  1. Towards development of optimal sequential injection analysis methods

    … A new technique in analytical chemistry called sequential injection analysis, may be able to provide a robust, inexpensive, automated method for detection of resin acids (known fish toxins) with appropriate use of immunochemical sensing. Most new analytical techniques, however, require …

    ubc Repository record for Towards development of optimal sequential injection analysis methods (opens in a new tab) Download PDF for Towards development of optimal sequential injection analysis methods (opens in a new tab)

  2. Sequential injection analysis for the investigation of biomolecular interactions

    This thesis presents the application of Flow and Sequential Injection technologies to problems of biomolecular interaction analysis. Both biochemical and biological systems are addressed.The biochemical application involved the development of a Sequential Injection-based Biosensor (SIB) for the …

    washington Repository record for Sequential injection analysis for the investigation of biomolecular interactions (opens in a new tab)

  3. Measurement of Radioactive Caesium Isotopes by Accelerator Mass Spectrometry

    … fractionation at the level of 0.8%. A slow sequential injection analysis technique was developed to measure 135Cs using 134Cs as a reference isotope. This technique also permitted the monitoring of Ba interference. The ionization efficiency of Cs when analyzed in the molecular anion form, …

    ottawa-retro Repository record for Measurement of Radioactive Caesium Isotopes by Accelerator Mass Spectrometry (opens in a new tab)

  4. Ανάπτυξη και Επικύρωση Μεθόδων για τον Προσδιορισμό της Αντιοξειδωτικής Ικανότητας Λευκών Οίνων με Αυτοματοποιημένες Διατάξεις Ροής

    … βασίστηκε στην τεχνική των διαδοχικών εγχύσεων (Sequential Injection Analysis, SIA), ενώ η δεύτερη μέθοδος βασίστηκε στην τεχνική της έγχυσης δείγματος σε ροή (Flow Injection Analysis, FIA) χρησιμοποιώντας το γαλλικό οξύ ως πρότυπο αντιοξειδωτικό. Αρχικά, έγινε μελέτη της στατιστικής …

    athens Repository record for Ανάπτυξη και Επικύρωση Μεθόδων για τον Προσδιορισμό της Αντιοξειδωτικής Ικανότητας Λευκών Οίνων με Αυτοματοποιημένες Διατάξεις Ροής (opens in a new tab)

  5. Advances in flow extraction techniques: applications in forensic toxicology

    … Two new extraction techniques were developed; a sequential injection liquid extraction manifold and a fiber optic fluorescence detector for monitoring a heterogeneous immunoassay. The merits of each were compared to conventional methods in forensic toxicology.Conventional liquid solvent …

    washington Repository record for Advances in flow extraction techniques: applications in forensic toxicology (opens in a new tab)

  6. Phosphate Based Proof Of Concept For A Microfluidic Multi-nutrient In-situ Auto-analyzer

    … assays without loss in sensitivity. Micro Sequential Injection Analysis (μSIA) represents the second generation of flow injection analysis (FIA) techniques and solved many of the problems inherent to Continuous Flow Analysis (CFA) and first generation of FIA. The μSIA system comprises (one …

    hawaii Repository record for Phosphate Based Proof Of Concept For A Microfluidic Multi-nutrient In-situ Auto-analyzer (opens in a new tab)

  7. Development of a chemical sensor for the measurement of dissolved inorganic carbon in seawater

    … principle in combination with a gas diffusion sequential injection analysis : (i) a custom-made four-hollow brass electrode detection cell, and (ii) a custom-made gas exchange unit with a “Tube In A Tube” configuration. The bench-top analyzer was validated through laboratory experiments and …

    cau-kiel Repository record for Development of a chemical sensor for the measurement of dissolved inorganic carbon in seawater (opens in a new tab)

  8. Some novel electrochemical detection systems for flowing solution analysis

    … for use with an amperometric array in flowing injection analysis. Control of the purpose instrumentation was effected with a 486-33 MHz personal computer and Analog Devices RTI-815 and RTI-817 data acquisition\control cards which were responsible for hardware control functions and data …

    dcu Download PDF for Some novel electrochemical detection systems for flowing solution analysis (opens in a new tab)

  9. The distribution of aluminum in Beaufort Sea and the development of a sequential injection method for the determination of aluminum in natural waters

    … and acidified to pH 1.7 for two year prior to analysis) for the Arctic Ocean which indicate that a significant proportion of Al in the water column is present in the > 0.2 um fraction. These measurements and the hydrographic data along the transect indicate the transport of a cold, saline, …

    uvic Repository record for The distribution of aluminum in Beaufort Sea and the development of a sequential injection method for the determination of aluminum in natural waters (opens in a new tab)

  10. Development of an Ultrasensitive Capacitive DNA-sensor: A promising tool towards microbial diagnostics

    … task in medical diagnostics, environmental analysis and evaluation of food safety. Accordingly, the idea of microorganism identification by the recognition of specific DNA sequence using electrochemical technique is one of the leading researches in the development of diagnostic devices. In …

    lund Repository record for Development of an Ultrasensitive Capacitive DNA-sensor: A promising tool towards microbial diagnostics (opens in a new tab) Download PDF for Development of an Ultrasensitive Capacitive DNA-sensor: A promising tool towards microbial diagnostics (opens in a new tab)

  11. Development of automatic methods for trace metals determination using on-line separation and preconcentration techniques coupled with atomic spectrometry

    The combination of flow injection analysis (FIA) with atomic absorption spectrometry has revolutionized the analytical methods and techniques. Most attention is focused on the development new methods analytical techniques. Three of on-line preconcentration methods have been developed for cadmium …

    greece Repository record for Development of automatic methods for trace metals determination using on-line separation and preconcentration techniques coupled with atomic spectrometry (opens in a new tab)

  12. Ανάπτυξη νέων μεθόδων προσδιορισμού ολικής αντιοξειδωτικής ενεργότητας και εφαρμογή στο ελαιόλαδο

    … while the human intervention is minimized. Flow injection (FI) and the newer sequential injection (SI) analysis are the most applicable automation techniques. They incorporate the technological development in both microdevices and microcomputers. The frequency of measurements is increased, data …

    greece Repository record for Ανάπτυξη νέων μεθόδων προσδιορισμού ολικής αντιοξειδωτικής ενεργότητας και εφαρμογή στο ελαιόλαδο (opens in a new tab)