Development of an Experimentally-Validated Compact Model of a Server Rack
… was developed. The compact model was based on a server simulator, which dissipates a variable amount of heat at an adjustable air flow rate. Even though a server simulator does not accurately represent the geometry of an actual electronics enclosure, the modeling of such a unit deals with many of …
-
Control of data center cooling using data driven heuristic approach
… with heuristic temperature prediction of the server rack inlet temperature results in reaching a target server rack temperature in ~30 min. This thesis addresses energy savings through another case study, in which dynamic controls utilize outside air economization, resulting in energy …
-
A series-stacked power delivery architecture with isolated converters for energy efficient data centers
… The conventional way of delivering DC power to a server rack in data centers generally contains a central converter that regulates a DC bus, which is typically at 380V rectified grid voltage. This 380V bus voltage is in turn fed to each server rack and one DC-DC converter per server then converts …
-
Monolithic electronic-photonic integration of the light-emitting transistor
Server technologies such as network storage, multi-core processing, video conference and mobile data are contributing to the ever increasing bandwidth requirement. It has become challenging to meet the demand for bandwidth, energy efficient and reliable optical interconnects. The development of an …
-
The Zero Inductor-Voltage Converter
Data centers and servers are one of the largest growing consumers of electrical power in the world today. In data center power distribution, the majority of the loss still occurs in the final conversion stages at the server rack, and server board level. A 48-volt architecture has been proposed, and …
-
Improving data center power delivery efficiency and power density with differential power processing and multilevel power converters
… computational loads in a custom designed four-server rack. In order to provide a complete grid-to-12 V power delivery for data center applications, this dissertation also proposes a buck-type power factor correction converter that yields high power density between a single-phase grid and the dc …
-
Investigating Emerging Security Threats in Clouds and Data Centers
… uncover effective thermal attack vectors at the server, rack, and data center levels. We also present damage assessments of thermal attacks. Our results demonstrate that thermal attacks can negatively impact the thermal conditions and reliability of victim servers, significantly raise the cooling …
-
Design of SCALDO based high-current DC power supply
… announced their intention to move toward 48 V server rack architecture to minimise power losses in distribution lines and to improve overall operating efficiency. This thesis investigated the potential of the SCALDO technique to develop a high-current DC power supply suitable for Google server …
-
Heterogeneous computing environment characterization and thermal-aware scheduling strategies to optimize data center power consumption
… in computing at different levels: chip, server, rack, and data center. Many of today's data centers experience physical limitations on the power needed to run the data center. The first problem that is studied in this thesis is maximizing the performance of a data center that is subject …
-
Power Architectures and Design for Next Generation Microprocessors
… power-hungry processors, driving the power per server rack to 20 KW levels. The need for more efficient power management solutions on the architecture level, down to the converter level, is inevitable. Recently, data centers have replaced the 12V DC server rack distribution with a 48V DC …
-
Optimization of row-and-rack level airflow management in data centers
… cooling, this thesis proposes row-and-rack level airflow management is worth further studying. Then, 4 different row-and-rack level methods are proposed and studied to optimize the thermal environment through experimental & numerical studies and model validation. The numerical models …
-
Air flow management inside data centres
… as an infrastructure facility that houses file servers, processors and other computer equipment, along with a standby power supply. These servers are kept inside cabinets and those cabinets are called racks. These racks are located close to each other inside a data centre to form rows. These …
-
Multiphase Hybrid Switched-Capacitor Buck Converters: Synthesis, Packaging, Modelling, and Control for HPC Applications
… distribution voltage of the busbars within each server rack has shifted from 12V to 48V. Simultaneously, modern microprocessors—enabled by advances in semiconductor manufacturing and lithography—are operating at sub-1V core voltages. This creates a challenging power conversion gap. Unfortunately, …
-
Multi Resonant Switched-Capacitor Converter
This thesis presents a novel Resonant Switched-Capacitor Converter with Multiple Resonant Frequencies, abbreviated as MRSCC for both high density and efficiency non-isolated large step-down Intermediate Bus Converter (IBC). Conventional Resonant Switched-Capacitor Converter (RSCC) proposed by …