Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"Shadow Shield"”

  1. Clinical studies using a high sensitivity shadow-shield mobile whole body monitor

    … by the author using a high sensitivity, shadow-shield, mobile, whole body monitor and is primarily concerned with its clinical applications. Whole body counting-rates vary when administered radioisotopes are redistributed in the body. Several methods of assessing the magnitude of …

    st-andrews Repository record for Clinical studies using a high sensitivity shadow-shield mobile whole body monitor (opens in a new tab)

  2. Evaluation of ISO 4037-1:1996 and the Shadow Shield Technique for the Measurement of Scattered Radiation

    … yet fail the scatter limit criterion. The shadow shield technique is another widely accepted test used to determine the scatter contribution. Using the same MCNP model, an analysis of the shadow shield technique was performed. It was found that, using the definition of scatter found in ISO …

    ohiolink Repository record for Evaluation of ISO 4037-1:1996 and the Shadow Shield Technique for the Measurement of Scattered Radiation (opens in a new tab)

  3. Mass and shielding optimization studies for a low enrichment uranium fueled kilopower space nuclear reactor

    … space reactor based on mass-optimization and shielding considerations. The HEU-fueled Kilowatt Reactor Using Stirling TechnologY (KRUSTY) serves as a basis for a similar reactor fueled with LEU fuel. Zirconium hydride moderator is added to the core in four different configurations (a …

    colo-mines Repository record for Mass and shielding optimization studies for a low enrichment uranium fueled kilopower space nuclear reactor (opens in a new tab)

  4. Development of High Resolution Counting Techniques for Body Radioactivity Measurements

    … effort has been spent on the modification of the shadow-shield whole-body counter at SURRC. The shadow-shield was reorganized to accommodate up to four n-type LOAX detectors and one 80% p-type HPGe-detector along with the two NaI(T1) detectors already present. This detector arrangement has …

    glasgow Repository record for Development of High Resolution Counting Techniques for Body Radioactivity Measurements (opens in a new tab)

  5. Design of a neutron spectrometer and simulations of neutron multiplicity experiments with nuclear data perturbations

    … unique to each neutron source. The design of a shadow shield to account for room scattered neutrons was investigated as well. For sufficient source strength in a void, the optimal geometric design was able to detect all sources in 1000 trials, where each trial consists of simulated detector …

    ksu Repository record for Design of a neutron spectrometer and simulations of neutron multiplicity experiments with nuclear data perturbations (opens in a new tab)

  6. Evaluation of Scattered Radiation in a Calibration Range Using Exposure Rate Energy Spectra

    … reported the results of an MCNP analysis of the shadow shield technique that was performed for a calibration range with a Cs-137 irradiator. This thesis examines the energy distribution of the photons contributing to the exposure percent scatter (S%) and the detailed origin of the scatter that …

    ohiolink Repository record for Evaluation of Scattered Radiation in a Calibration Range Using Exposure Rate Energy Spectra (opens in a new tab)

  7. Πρωτότυπος μετρητής ολοσώμου γ-ακτινοβολίας και η χρήση του στον in-vivo προσδιορισμό του ραδιενεργού καλίου και καισίου

    … of a prototype whole body and partial body shadow shield γ-counter, as well as the study and determination of charasteristic parameteres (i.e sensitivity, uniformity) and calibration of γ-counter. The originality of the γ-counter consists in that the distance between the detectors easily …

    greece Repository record for Πρωτότυπος μετρητής ολοσώμου γ-ακτινοβολίας και η χρήση του στον in-vivo προσδιορισμό του ραδιενεργού καλίου και καισίου (opens in a new tab)

  8. Whole-body monitoring and in vivo activation analysis in nuclear medicine

    … monitor has been developed utilising a shadow shield weighing 7-8 tons compared with conventional shields of 30-50 tonas. Construction of the prototype monitor and an assessment of its performance lead to the conclusion that sensitivity at least comparable with that of the conventional …

    glasgow Repository record for Whole-body monitoring and in vivo activation analysis in nuclear medicine (opens in a new tab)

  9. Design Criteria for High Resolution Gamma-Ray Body Counting Systems

    … detector body counting systems with regard to shielding,background,detector volume and other relevant factors with the ultimate goal of setting up such a system at the Scottish Universities Research and Reactor Centre. Following recommendations made in recent years for the need to monitor …

    glasgow Repository record for Design Criteria for High Resolution Gamma-Ray Body Counting Systems (opens in a new tab)

  10. An Evaluation of Shadow Shielding for Lunar System Waste Heat Rejection

    Shadow shielding is a novel and practical concept for waste heat rejection from lunar surface spacecraft systems. A shadow shield is a light shield that shades the radiator from parasitic thermal radiation emanating from the sun or lunar surface. Radiator size and mass can reduce if the radiator is …

    tamu Repository record for An Evaluation of Shadow Shielding for Lunar System Waste Heat Rejection (opens in a new tab)

  11. Skeletal scintigraphy and quantitative tracer studies in metabolic bone disease

    … Tc-99m diphosphonate (WBR) is measured using a shadow-shield whole-body monitor. At 24 hours after injection, diphosphonate has reached a stable equilibrium in bone reflecting skeletal metabolic activity, while tracer in the soft-tissues of the body has been largely excreted via the urinary …

    glasgow Repository record for Skeletal scintigraphy and quantitative tracer studies in metabolic bone disease (opens in a new tab)

  12. Ανάπτυξη και εφαρμογή μεθόδων μέτρησης ραδιονουκλιδίων με μετρητή ολόσωμης ακτινοβολίας

    … injection, inhalation, ingestion. A prototype, shadow shield, moving bed WBC was installed at the University of Ioannina Medical Physics Laboratory. Radiation detection is carried out by fourteen cylindrical NaI(Tl) detectors with nominal dimensions 15.7 cm × 5.0 cm, located in groups of seven …

    greece Repository record for Ανάπτυξη και εφαρμογή μεθόδων μέτρησης ραδιονουκλιδίων με μετρητή ολόσωμης ακτινοβολίας (opens in a new tab)