Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"Shaped Electrode"”

  1. Characterization of a high-density, large-area VHF plasma source

    Feasibility Study of Shaped Electrode The objective of this project was a feasibility study of a novel, large-area plasma reactor for thin film production, based on a shaped electrode technique ("lens") to compensate the standing wave non-uniformity. Cylindrical Test Reactor In the first phase a …

    epfl Repository record for Characterization of a high-density, large-area VHF plasma source (opens in a new tab)

  2. Tactile actuator with electroactive polymer

    A new actuation principle with electrodes around the deformation region for a DEAP membrane used as a driving component of a tactile actuator is developed. Compared to DEAP actuation with electrodes covering the deformation region, the stiffening effect induced by the electrodes is drastically …

    freiburg-diss Repository record for Tactile actuator with electroactive polymer (opens in a new tab)

  3. Frequenzselektive Vibrationssensoren mit spannungsgesteuerter Resonanzabstimmung in Oberflächenmikromechanik

    … terms of nonlinearity. A novel type of specially shaped electrode systems offering linear properties within an amplitude range of 10 micrometers, so-called curved comb capacitors, is developed for fabrication in SCREAM technology.

    qucosa-diss Repository record for Frequenzselektive Vibrationssensoren mit spannungsgesteuerter Resonanzabstimmung in Oberflächenmikromechanik (opens in a new tab)

  4. Machining of High-Aspect-Ratio Single and Multi Electrodes using EDM-based Techniques

    … of dimensionally accurate, high-aspect-ratio electrodes remains a challenge in advanced manufacturing. Their effective production yields higher-quality microfeatures on difficult-to-machine workpieces, enhances machining of thicker materials, and maintains longer effective tool life. This …

    ohiolink Repository record for Machining of High-Aspect-Ratio Single and Multi Electrodes using EDM-based Techniques (opens in a new tab)

  5. Recording properties of a concentric needle electrode for electromyography as measured in an electrolytic tank model

    The widely used concentric needle electrode produces electromyograms that do not exactly correspond to the true signal in the muscle. The presence of the electrode induces distortions of the original field distribution in the muscle, and the cannula does not act as a perfect reference electrode of …

    ubc Repository record for Recording properties of a concentric needle electrode for electromyography as measured in an electrolytic tank model (opens in a new tab)

  6. Droplet actuation on various electrode shapes in electrowetting-based microfluidics

    … experimental study to investigate the effect of electrode shape in electrowetting-based microsystems. A new crescent-shaped electrode is proposed which provides a uniform actuation force at the contact line as well as overlap between the adjacent electrodes. The onset of actuation and droplet …

    concordia

  7. EXPLORING PH GRADIENT PHENOMENA IN NON-LINEAR ELECTROKINETIC MICROFLUIDIC DEVICES

    … the fundamental phenomena originate from microelectrodes utilized in the electrokinetic systems whose surface reactions drive ion byproducts into the adjacent medium. The medium variations can thus affect the cell’s viability as well as bioparticle structure and function. The research results …

    mtu Repository record for EXPLORING PH GRADIENT PHENOMENA IN NON-LINEAR ELECTROKINETIC MICROFLUIDIC DEVICES (opens in a new tab)

  8. Development Of Carbon Based Neural Interface For Neural Stimulation/recording And Neurotransmitter Detection

    … communicate with the nervous system via electrodes are of great significance. Recently, flexible neural interfaces that combine carbon nanotubes (CNTs) and soft polymer substrates have generated tremendous interests. CNT based microelectrode arrays (MEAs) have shown enhanced …

    wayne-thes Repository record for Development Of Carbon Based Neural Interface For Neural Stimulation/recording And Neurotransmitter Detection (opens in a new tab)

  9. Scanning Electrometer for Electrical Double-layer (SEED) : The direct measurement of ion dynamics for biosensor

    As a working electrode (WE) comes in contact with an electrolyte, an electrical double layer (EDL) forms. EDL is the ion accumulation at the surface of the WE. Typically, the thickness of EDL is ~2nm. All electrochemical phenomena, i.e. redox reaction, which take place at the electrode surface, …

    nebraska Repository record for Scanning Electrometer for Electrical Double-layer (SEED) : The direct measurement of ion dynamics for biosensor (opens in a new tab)

  10. Experimental Studies of Fluctuations and Turbulences in the STOR-M Tokamak and TJ-II Stellarator

    … to improve plasma confinement purposes. The electrode biasing and wall conditioning have crucial effect on the plasma transport and fluctuating flux suppression at the edge region of the plasma. Electrode biasing involves a modification on the edge radial electric field which in turn …

    sask Repository record for Experimental Studies of Fluctuations and Turbulences in the STOR-M Tokamak and TJ-II Stellarator (opens in a new tab)

  11. Optical Fluid-based Photonic And Display Devices

    … conceive a dielectric liquid microlens with well-shaped electrode for fixing the droplet position and lowering the operating voltage. To widen the dynamic range, we demonstrate an approach to enable focus tuning from negative to positive or vice versa in a single dielectric lens without any moving …

    ucf Repository record for Optical Fluid-based Photonic And Display Devices (opens in a new tab)

  12. ALTERNATING CURRENT DIELECTROPHORETIC MANIPULATION OF ERYTHROCYTES IN MEDICAL MICRODEVICE TECHNOLOGY

    … type was injected into a microdevice with a T-shaped electrode configuration and the erythorcytes were found to rupture at a rate specific to their ABO-Rh blood type. The second set of experiments, presented in Chapter 5, were originally published in Electrophoresis in 20111. Novel in this work …

    mtu Repository record for ALTERNATING CURRENT DIELECTROPHORETIC MANIPULATION OF ERYTHROCYTES IN MEDICAL MICRODEVICE TECHNOLOGY (opens in a new tab)

  13. Advanced MEMS Microprobes for Neural Stimulation and Recording

    … by Medtronic, provide only four cylindrical shaped electrode sites, each 1.5 mm in height and 1.27 mm in diameter. Although suitable for the stimulation of a large brain volume, to measure the activity of a single neuron but to avoid measuring the average response of adjacent cells, recording …

    waterloo Repository record for Advanced MEMS Microprobes for Neural Stimulation and Recording (opens in a new tab)

  14. Advanced Blue Phase Liquid Crystal Displays

    … On the device side, with protrusion and etched electrodes, we can reduce the operating voltage to below 10V and enhance the transmittance to over 80%. On the material side, high Kerr constant is indeed helpful for lowering the operation voltage, but we also need to pay attention to the …

    ucf Repository record for Advanced Blue Phase Liquid Crystal Displays (opens in a new tab)

  15. Investigations of radio-frequency, capacitively-coupled large area industrial reactor : cost-effective production of thin film microcrystalline silicon for solar cells

    … effect can be eliminated by symmetrizing the two electrodes. It is also shown that the standin-gwave affects significantly the film microstructure of microcrystalline silicon deposited from discharges with a silane input concentration about 10 %, whereas for low input silane concentrations (< 4 – …

    epfl Repository record for Investigations of radio-frequency, capacitively-coupled large area industrial reactor : cost-effective production of thin film microcrystalline silicon for solar cells (opens in a new tab)

  16. Development of Levitated Magnetic Resonance and Electron Optics Investigations in Gyrotrons

    … circuit board (PCB) was made, using a center electrode at a DC voltage, surrounded by an Ω-shaped electrode at an AC voltage of around ±2.5 kV. With the planar trap, particle sizes up to ~200 µm diameter could be stably trapped. The trap is stable for days and tolerant to having an additional …

    ethz Repository record for Development of Levitated Magnetic Resonance and Electron Optics Investigations in Gyrotrons (opens in a new tab)

  17. Electromagnetic Analysis of Exposure Systems - Potential Factors Underlying the Variation in Duration of Nanosecond Electric Pulse-Evoked Changes in Intracellular Calcium Level in Adrenal Chromaffin Cells

    … by a 5 ns, 5 MV/m pulse using a pointy rod electrode exposure system, Ca2+ responses were more prolonged, in some cases such that [Ca2+]i never returned to pre-stimulus levels during the monitoring period. Because the basis of this prolonged rise in [Ca2+]i is not yet known, the main …

    unr Repository record for Electromagnetic Analysis of Exposure Systems - Potential Factors Underlying the Variation in Duration of Nanosecond Electric Pulse-Evoked Changes in Intracellular Calcium Level in Adrenal Chromaffin Cells (opens in a new tab)