Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 76 for “"Sharp-edge"”.
-
Advancing Compound Detection and Identification Using Vibrating Sharp-Edge Spray Ionization
… Detection and Identification Using Vibrating Sharp-Edge Spray Ionization Anthony Paul DeBastiani ‘Omics consists of various areas, including genomics, proteomics, lipidomics, and metabolomics with a goal of detection and identification of biomolecules present within each of these classes …
-
Expanding the Vibrating Sharp-Edge Spray Ionization Toolkit for Oligonucleotide Characterization
A gentle or soft Ionization process is a critical component in native mass spectrometry (MS) to lift the biomolecules from the bulk solution into the gas phase environment of the mass spectrometer preserving their shape, topology and non-covalent interactions. Electrospray ionization (ESI) …
-
Isokinetic Sampling Efficiency Differences for Blunt Edge vs Sharp Edge Sampling Probes
… efficiency differences are present between a sharp edge probe and a blunt edge probe during isokinetic sampling. To answer this question, isokinetic sampling was performed inside a wind tunnel. Sampling was performed with the sharp edge probe and compared to data previously obtained using the …
-
Evolution of Large-Scale Structures in the Wake of Sharp-Edge Thin Flat Bodies
… to 2D plates. Vortices are formed on longer edges of the plate, whereas shear layers on the shorter sides are carried away by the induced streamwise flow. This results in a single vortex shedding process. The vortex “peel-off” on shorter edges fixes the vortex detachment at sharp corners of …
-
Development of Capillary Vibrating Sharp-Edge Spray Ionization for Improving Continuous Flow Mass Spectrometry Analysis
Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) is new ionization technique developed in the year of 2018. This ionization technique has attractive features such as simplicity, compactness, ease of manipulation, low costs, compatible with continuous flow, etc. However, the development of …
-
Development of Vibrating Sharp-edge Spray Ionization (VSSI) methods for Mass Spectrometry Analysis and Imaging
… a novel ionization method termed vibrating sharp-edge spray ionization (VSSI) that nebulizes liquids efficiently at the edge of a vibrating glass slide has been reported. The work in this thesis leverages the capabilities of VSSI for continuous flow-based analysis, surface chemical analysis, …
-
Enhancing Negative-Ion Native Mass Spectrometry with Field-Assisted Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI)
… can be costly. In this work, capillary vibrating sharp-edge spray ionization (cVSSI) is implemented for negative-ion, native-MS experiments. Early on, VSSI demonstrated an ability to behave as a soft ionization technique similar to ESI. In the present study, a simple modification of cVSSI is …
-
Development and Applications of Capillary Vibrating Sharp-Edge Spray Ionization Coupled with Atmospheric Pressure Chemical Ionization (cVSSI-APCI)
… A spray-based technique, Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI), that has been demonstrated to perform as well, or better than, ESI has been successfully coupled with a corona discharge to create cVSSI-APCI. Initial work performed to demonstrate the utility of cVSSI-APCI with …
-
An analytical method for predicting the lift and drag for slender sharp-edge delta wings in ground proximity
… a vortex lift concept and applied to slender sharp-edge delta wings. A multihorseshoe vortex lattice method incorporating an image technique is used to compute the potential flow normal force and axial force characteristics of delta wings in ground proximity. A free-air vortex lift concept …
-
Native Mass Spectrometry using Capillary Vibrating Sharp-Edge Spray Ionization and Surface Analysis on Thin Films used in Superconducting Detectors
… Mass Spectrometry using Capillary Vibrating Sharp-Edge Spray Ionization and Surface Analysis on Thin Films used in Superconducting Detectors Vikum Kanishka Dewasurendra My thesis is made up of two projects. The main project involves using a novel native mass spectrometry (MS) source to …
-
Development of Lab-on-a-Chip platforms incorporating a novel Acoustic atomization induced pump based on a vibrating sharp edge capillary.
Capillary Vibrating Sharp-edge Ionization device (cVSSI device) was developed by our laboratory with a low cost and an easy fabrication procedure. The generation of small liquid droplets by this technique has been used as an ionization source for mass spectrometry analysis platforms. On usual …
-
Flexural Wave Based Acoustofluidic Devices
… specific subset of these technologies, termed sharp-edge based acoustofluidics, has shown promise in a variety applications; specifically, previous work has explored the use of this technology in applications such as fluid pumping and mixing, cell stimulation, and bio-sample preparation. …
-
Optimizing seat and ball combination of actual gas lift valve: an experimental and CFD simulation study
… This is almost always the case when conventional sharp-edge seats are used in GLVs. A modified design for the GLV seats (partly beveled, partly sharp-edge) was present in the literature for a long time which is supposed to enable the stem to travel less compared to sharp-edge seat design for the …
-
Measurement and Prediction of the Separated Flow on a Rotor at High Advance Ratio
… presence of two distinct vortex structures, a ``sharp-edge'' vortex and a ``blunt-edge'' vortex, believed to dominate unsteady loading in the reverse flow region. The sharp-edge vortex was studied via a high-fidelity numerical simulation, and its growth was found to be dominated by 2-D mechanisms …
-
Development and implementation of a novel voltage-free interface for capillary electrophoresis-mass spectrometry separations of proteins
… A new interfacing method based on vibrating sharp-edge spray ionization is presented in this work to overcome the challenges of decoupling applied voltages and to enhance the compatibility with separations performed at near-neutral pH. The versatility and ease of use of this ionization source …
-
Evaluation of Shear Bond Strength of Zirconia to Resin Cement After Surface Treatment with Different Air Abrasion Zirconia Particles
… abrasive particles, zirconia (beads and sharp edge particles) and aluminum oxide sharp edge in comparison to control (no surface treatment)...Result: A significant increase in shear bond strength in all surface treatment groups compared to control. Aluminum oxide abrasive particle surface …
-
The Diffraction of Polarized Light by a Conducting Straight Edge in the Geometrical Shadow
… the diffraction pattern of a conduction straight edge will show deviations from the diffraction pattern of a non-conductor, and further, that these deviations will depend upon the polarization of the incident light. In this experiment the diffraction of polarized, coherent light from a …
-
13 to 27 MeV helium-3 elastic scattering from several light nuclei
… in terms of a local optical potential and a sharp edge diffraction model and the results compared to other experiments. Each isotope is discussed and possible explanations for some of the experimental discrepancies with these models are given.
-
Harnessing Acoustic Streaming for Bioanalysis in Microfluidics
… based on acoustic streaming generated from sharp-edge structure vibration and achieved rapid and homogeneous mixing of fluids in microscale. Based on this mixing principle, an acoustic streaming-based microfluidic method was developed and performed all the fluid and particle operations of …
-
Response dynamics of retinal ganglion and early visual cortical cells to simulated optical blur
… and V1 neurons have been extensively studied. Sharp transitions in luminance signify edges, which are key features in the visual environment. However, edges are rarely sharp and may be blurred. Edges are generally blurred because eyes have a restricted depth of field, sources of light are …
Page 1 of 4