Finite Element Analysis of Single Plate Shear Connections
… have been several design models for single plate shear connections in the past 20 years. The current design model states that the bolt shear rupture strength of a connection is a function of the number of bolts and the a-distance, which is the distance from the weld line to the bolt line. The …
-
Innovative Shear Connections for the Accelerated Construction of Composite Bridges
… construction of composite bridges, a proper shear connection detail is needed to develop composite action between the steel plate girders and the precast concrete deck panels. This research project investigated two types of shear connection that would accelerate the construction of …
-
Behavior of beam shear connections in steel buildings subject to fire
… on the behavior of steel simple beam end framing connections subjected to fire. While significant progress has been made in understanding the overall structural response of steel buildings subject to fire, the behavior of connections under fire conditions is not well understood. Connections are …
-
Structural Behavior of Lap Shear Connections with Thermally Insulating Filler Plates
… and numerical simulations of structural steel connections with various filler materials to study the effect of non-steel fillers on the connection strength. Non-steel fillers are used in the steel connections to provide thermal insulation by reducing thermal bridging. Eight specimens having …
-
DETECTION OF FATIGUE DAMAGE IN SHEAR CONNECTIONS USING ACOUSTIC WAVE PROPAGATION
… is an important concern in structural steel connections where frequent load reversals are expected. Detection of fatigue damage is typically done with infrequent visual inspections that are subjective and limited to surface features. A permanent embedded structural health monitoring (SHM) …
-
Fatigue Assessment of Resin-Injected Bolted Shear Connections: From Material to Structural Detail
A construção de pontes metálicas teve uma grande expansão por todo o mundo durante os séculos 19 e 20 sendo que, uma parte significativa destas estruturas encontram-se ainda em serviço. É essencial não só avaliar a sua integridade estrutural, mas também desenvolver soluções de reforço com o …
-
Contribution of Shear Connections to the Lateral Stiffness and Strength of Steel Frames
… efforts involving the capacity of simple gravity connections have since increased significantly. Typically, a building includes more gravity connections than moment connections, yet the moment resistance contributions of the gravity connections are neglected in design. Based on the lack of …
-
Shear Connections for the Development of a Full-Depth Precast Concrete Deck System
… lacking design direction is the development of a shear connection between the full-depth precast deck and a precast concrete girder via a pocket-haunch-connector system. Push-off tests are performed to investigate the effects of various pre- and post-installed shear connectors, haunch height, …
-
Experimental investigations of shear connections with self-tapping-screws for cross-laminated-timber panels
… mid-rise construction. CLT structures and their connections need to be designed for appropriate capacity, stiffness, and if applied in seismic zones – ductility; however, current North American design standards contain no provisions for STS in CLT. The research developed in this dissertation …
-
Fiber Orientation in Ultra-High-Performance Concrete (UHPC) Shear Connections in Adjacent Box Beam Bridges
Replacing the grout used in adjacent box beam shear connections with Ultra-High-Performance Concrete (UHPC) could potentially reduce or eliminate joint cracking, thus increasing the bridge’s lifespan and reducing maintenance costs. The strength of UHPC is influenced by the orientation of the small …
-
A comparison of double clip angle shear connections to shear tab connections in industrial applications
In structural steel connection design, simple shear connections are one of the most common connection types utilized. The industry, especially from the side of the engineer, tends to lean toward using Double Clip Angle Connections as the default standard for simple shear connections. A double clip …
-
A Systematic Investigation of Shear Connections Between Full-Depth Precast Panels and Precast Prestressed Bridge Girders
… connectors are required to transmit horizontal shear across the interface between the girder and deck. Shear connector performance is characterized by a series of experiments performed on part of a bridge system that mimics a full-depth precast deck on concrete girder with a …
-
The Effects of Bolt Pretension, In-Plane Eccentricity, and Friction on the Ductility of Block Shear Connections
Block shear is a complex failure mechanism in bolted and welded steel components such as gusset plates, webs of coped beams, angles and tees. It presumes a combination of tension rupture and shear yield. Multiple variables affect the block shear capacity and ductility of a connection. This study …
-
Parametric Study on the Behavior of Extended Single Plate Shear Connections Subjected to Combined Shear and Compression Forces
Extended single plate shear connections are very commonly used in industry as they make the construction process easier by avoiding the need for coping of the beam. Numerous experimental testing and analytical studies have been performed to understand their behavior under gravity induced shear …
-
Reduced component model for double-angle shear connections considering the contribution of the concrete slab for cyclic analysis of steel structures
Double-angle web shear connections are commonly used in steel gravity framing, and they are usually idealized as pinned connections during analysis. The nonlinear behavior of these connections has been studied during the last decades by researchers aiming to develop methodologies to simulate …
-
Experimental and analytical study of the shear transfer in composite shallow cellular floor beams
This research investigated the longitudinal shear transfer mechanism in composite shallow cellular floor beams. The shear transfer mechanism is different with the headed shear studs used in composite construction. The shear resisting properties and behaviour of the shear transfer mechanism has not …
-
Strength of welded shear studs
… were conducted to study the behavior of welded shear studs. Forty-eight solid slab push-out tests were conducted to study how stud tensile strength and concrete properties affect the strength of shear connections. It is shown that raising the tensile strength of a shear connector actually has an …
-
Cold-Formed Steel Bolted Connections without Washers on Oversized and Slotted Holes
The use of the cold-formed steel sheet bolted connections without washers is so significant; however, the North American Specifications for the Design of Cold Formed Steel Structural Members, NASPEC, doesn't provide provisions for such connections. The bearing failure of sheet and the shear failure …
-
Experimental Verification of a New Single Plate Shear Connection Design Model
Single plate shear connections are designed to have sufficient strength to resist the shear force and moment transferred from the beam. The connections must also provide sufficient ductility to allow the beam end to rotate freely. In the United States the current recommended design method is found …