Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 118 for “"Shear Connectors"”.

  1. Behaviour of channel shear connectors : push-out tests

    … the testing of push-out specimens with channel shear connectors. The test program involved the testing of 78 push-out specimens and was aimed at the development of new equations for channel shear connectors embedded in solid concrete slabs and slabs with wide ribbed metal deck oriented parallel …

    sask Repository record for Behaviour of channel shear connectors : push-out tests (opens in a new tab)

  2. Behaviour of demountable shear connectors in composite structures

    … is to evaluate the feasibility of demountable shear connectors as an alternative to welded shear connectors in composite structures through push off tests and composite beam tests. Push off tests were conducted to examine the shear strength, stiffness and ductility of demountable shear …

    bradford Repository record for Behaviour of demountable shear connectors in composite structures (opens in a new tab)

  3. Horizontal Shear Connectors for Precast Prestressed Bridge Decks

    … as for new bridge construction. The horizontal shear strength at the interface between the two interconnected elements is of primary importance in order to provide composite action. The strength of the bond between the two precast members should be high enough to prevent any progressive slip …

    vt Repository record for Horizontal Shear Connectors for Precast Prestressed Bridge Decks (opens in a new tab)

  4. Behavior and Strength of Welded Stud Shear Connectors

    The behavior and strength of welded shear studs are subjects of ongoing study. In recent years, research has shown that the American Institute of Steel Construction (AISC) specification equations for shear stud strength are unconservative for studs placed in deck with ribs transverse to the steel …

    vt Repository record for Behavior and Strength of Welded Stud Shear Connectors (opens in a new tab)

  5. BEHAVIOUR OF SLOTTED AND FLEXIBLE PERFOBOND RIB SHEAR CONNECTORS

    The perfobond rib connector is a new type of shear connector, first used in the construction of the Third Caroni bridge in Venezuela. Except for a limited number of proprietary tests conducted in Germany, research on perfobond rib shear connectors has been carried out mainly in Canada. Results of …

    sask Repository record for BEHAVIOUR OF SLOTTED AND FLEXIBLE PERFOBOND RIB SHEAR CONNECTORS (opens in a new tab)

  6. Standoff screws functioning as mechanical shear connectors in composite joists

    … standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, …

    vt Repository record for Standoff screws functioning as mechanical shear connectors in composite joists (opens in a new tab)

  7. Influence of shear connectors on the elastic behaviour of composite girders

    The effect of deformable and rigid connectors and influence of connection parameters on the behaviour of composite girders is examined. Both the elastic and plastic behaviour are discussed, but the former one is the main concern. Deformable connectors cause slip in the joint, which results in …

    aalto Repository record for Influence of shear connectors on the elastic behaviour of composite girders (opens in a new tab)

  8. Performance of GFRP reinforcement as friction shear connectors in concrete composite elements

    … integrity can be maintained only if the friction shear along the joint interface resulted from the gravity load is resisted. The characteristics of the reinforcement crossing the joint interface, concrete strength, and shear plane condition are some of the main factors controlling the integrity of …

    manitoba Repository record for Performance of GFRP reinforcement as friction shear connectors in concrete composite elements (opens in a new tab)

  9. On Thermal Bowing of Concrete Sandwich Wall Panels with Flexible Shear Connectors

    … concrete layer thickness, panel length, type of shear connector and separation using a commercial finite element analysis software. This study concluded that current design practices either underestimate, in the case of multiplying the classical mechanics values by the reported degree of …

    utahstate Repository record for On Thermal Bowing of Concrete Sandwich Wall Panels with Flexible Shear Connectors (opens in a new tab)

  10. Design of shear connectors for precast concrete decks in concrete girder bridges

    … effectiveness. These systems require the use of shear connectors between the precast concrete deck panels and the supporting girders to transfer interface shear and achieve composite action. The use of discrete clustered shear connectors is highly preferred in order to simplify panel and girder …

    nebraska Repository record for Design of shear connectors for precast concrete decks in concrete girder bridges (opens in a new tab)

  11. Evaluation of deck fasteners functioning as shear connectors for composite steel joists

    The use of deck fasteners as shear connectors for composite open web steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 …

    vt Repository record for Evaluation of deck fasteners functioning as shear connectors for composite steel joists (opens in a new tab)

  12. Strengthening existing steel bridge girders by the use of post-installed shear connectors

    … floor systems by the use of postinstalled shear connectors. Three types of post-installed shear connection methods were investigated. These methods are referred to as the double-nut bolt, the high tension friction grip bolt, and the adhesive anchor. These post-installed shear connectors …

    texas Repository record for Strengthening existing steel bridge girders by the use of post-installed shear connectors (opens in a new tab)

  13. The Fatigue Behaviour of Welded and Bolted Shear Connectors in Composite Highway Bridges

    … case of steel-concrete composite bridges, the shear connection between the concrete deck and the steel girders is a vital element of the bridge system, and has significant impacts on construction time, cost, structural integrity, and durability. The general performance of the shear connectors …

    waterloo Repository record for The Fatigue Behaviour of Welded and Bolted Shear Connectors in Composite Highway Bridges (opens in a new tab)

  14. Strengthening continuous steel girder bridges with post-installed shear connectors and inelastic moment redistribution

    … concrete deck over steel beams with no shear connectors. While many of these bridges are still in good condition, the structures may not satisfy current load requirements and thus may need to be strengthened or replaced to avoid load-posting and to maintain structural safety. One …

    texas Repository record for Strengthening continuous steel girder bridges with post-installed shear connectors and inelastic moment redistribution (opens in a new tab)

  15. HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK

    … investigation of the behavior of headed stud shear connectors embedded in slabs with wide ribbed metal deck oriented parallel to the beam. The test program involved the testing of 60 push-out specimens and 4 full-size beam specimens. The main objectives of this investigation were to evaluate …

    sask Repository record for HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK (opens in a new tab)

  16. Fatigue Performance and Shear Demand Distributions of Clustered Shear Connectors in Composite Bridge Girders

    … (AASHTO) Bridge Specifications assumes uniform shear flow demands at the steel-concrete interface of composite bridge girders. As stud pitch increases to beyond 24 in or as studs become clustered to account for pre-cast concrete decks, this assumed shear demand distribution may be …

    arkansas Repository record for Fatigue Performance and Shear Demand Distributions of Clustered Shear Connectors in Composite Bridge Girders (opens in a new tab)

Page 1 of 6