Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 1,111 for “"Shear Force"”
-
Development of fiber optic based shear force sensor
In this research, a novel FBG based shear force sensor is developed, for an absolute measurement of shear force.
-
Comparison of Slice Shear Force with Warner Bratzler Shear Force as Predictors of Consumer Panel Palatability Measures in Non-enhanced and Enhanced Pork Loin Chops
… evaluated the relationship between slice shear force (SSF) and Warner-Bratzler shear force (WBSF) as methods to determine pork tenderness and consumer sensory palatability measures. Data set one consisted of chops derived from non-enhanced pork loins (n = 607), that were purposely selected …
-
Mechanoelectrochemistry of electroactive polymers using shear-force based near-field microscopy
… microscope (SECM) hardware equipped with shear-force (SF) for characterizing ion transport in polypyrrole doped with dodecylbenzenesulfonate (PPy(DBS)). SECM-SF is based on positioning a vibrating 'ultra-microelectrode’ (UME) proximal to a PPy(DBS) film to monitor mechanoelectrochemistry. …
-
Relationships between Beef Postharvest Biochemical Factors and Warner-Bratzler Shear Force
… steaks. The most tender (< 30 N Warner Bratzler shear force (WBS)) and toughest Longissimus steaks (< 30 N WBS) from Angus, Braford, Brangus, and Simbrah heifers and steers were used. For Phase II, samples were obtained from a subset of Santa Cruz yearling heifers selected based of genotypes for …
-
The effect of coring method on beef Longissimus muscle shear force values
Photocopy of typescript.
-
The effect of coring method on beef Longissimus muscle shear force values
Photocopy of typescript.
-
Development of a tri-axial (vertical and shear) force measurement foot platform
… the world. It has long been thought that shear stresses on the plantar surface of the foot are a major contributing factor to the formation of these ulcers. Although there are many instruments available that measure the vertical foot pressure (vertical forces), there are currently no …
-
Consumer and shear force evaluation of steaks from the M. Serratus ventralis
… Steaks were also evaluated by Warner-Bratzler shear force (WBS) evaluations. Steaks from the M. Serratus ventralis were either blade tenderized, injected with a salt, phosphate, and papain solution, or served as a control. Consumers (n = 136) were not given a specific method of cookery, but …
-
Characterization of Mesoscopic Fluid-like Films with the Novel Shear-force/Acoustic Microscopy
The shear force mechanism has been utilized as a distance regulation method in scanning probe microscopes. However, the origin of shear force is still unclear. One of the most important reasons for the shear-force damping is due to the presence of a water contamination layer at the sample surface …
-
Identification of threshold levels for Warner-Bratzler shear force of beef value cuts
… determine threshold levels for Warner-Bratzler shear (WBS) force of the beef value cuts. USDA Choice and USDA Select M. biceps femoris, M. gluteus medius, M. infraspinatus, M. longissimus lumborum, M. rectus femoris, M. triceps brachii, and M. vastus lateralis steaks were evaluated for …
-
Optical contrast mechanisms and shear force interactions in near-field scanning optical microscopy.
… contrast for transmission mode NSOM and the force interaction between the probe and sample that is the basis for topographic imaging by shear force microscopy (SFM) are studied. A brief introduction and review of the field of NSOM are given. The lack of understanding in the previous work of …
-
Shear force impacts type IV pilus and flagellar dynamics during Pseudomonas aeruginosa surface adhesion
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2026-02-19 without embargo terms
-
Blind Shear Ram Blowout Preventers: Estimation of Shear Force and Optimization of Ram Geometry
… the last line of defense is the blind shear ram that is supposed to close and seal the wellbore by shearing through the drill string or any other tubing when they are in the wellbore.According to a recent report prepared for the U.S. Minerals Management Services (MMS) by [Childs et al., …
-
Quantification of cell adhesion strength on artificial surfaces with a microfluidic shear force device
… the inertness and attach to the coating by shear force induction through a hydrodynamic flow. This finding may explain the fact that the presence of hyaluronan is a prerequisite in the stem cell homing and engraftment process into the bone marrow. Besides receptor ligand interactions more …
Page 1 of 56