Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 52 for “"Shear connector"”.

  1. Comparing Sandwich Wall Panel Shear Connector Testing Methodologies

    … rapid construction, and thermal efficiency. Shear connectors are used to connect the two wythes of concrete to allow composite action of the system. In order to design concrete sandwich panel systems to act compositely, the engineer must obtain design values from a connector manufacturer, …

    utahstate Repository record for Comparing Sandwich Wall Panel Shear Connector Testing Methodologies (opens in a new tab)

  2. Push-out fatigue tests of the Alternate Shear Connector

    … (BISB) has led to an investigation of a new shear connector for steel-concrete composite structures. The new shear connector, known as the Alternate Shear Connector (ASC), was tested to determine its static strength and behavior using push-out tests with variables such as hole diameter, hole …

    iastate Repository record for Push-out fatigue tests of the Alternate Shear Connector (opens in a new tab)

  3. A deconstructable grout-reinforced hybrid shear connector for tall cross-laminated timber buildings

    … structural performance of a novel multi-material shear connector for mass timber and hybrid timber-based buildings, consisting of a threaded steel rod embedded into Cross-Laminated Timber (CLT), reinforced with a ring-layer of epoxy-based grout. The protruding rods may be bolted to steel beams or …

    ubc Repository record for A deconstructable grout-reinforced hybrid shear connector for tall cross-laminated timber buildings (opens in a new tab) Download PDF for A deconstructable grout-reinforced hybrid shear connector for tall cross-laminated timber buildings (opens in a new tab)

  4. Behaviour of Concrete Sandwich Wall Panels in Flexure Using a Novel GFRP Shear Connector

    … of a new concrete sandwich panel with a shear connector made of glass fibre reinforced polymer (GFRP) pultruded channel sections intended to enhance composite action and flexural rigidity while minimizing thermal bridging. The flanges of the channel section are embedded in either wythe. …

    queens Repository record for Behaviour of Concrete Sandwich Wall Panels in Flexure Using a Novel GFRP Shear Connector (opens in a new tab)

  5. Testing an alternate shear connector and the modifications to a beam-in-slab bridge system

    … Since there was not a top flange for welding shear studs, and since most counties do not have shear stud welding capabilities, an alternate shear connector (ASC) was developed to create composite action. The ASC investigated in this study consisted of torched holes in the top of the web with …

    iastate Repository record for Testing an alternate shear connector and the modifications to a beam-in-slab bridge system (opens in a new tab)

  6. Finite element modelling of steel-concrete composite structures

    … of the behaviour of the headed stud shear connector in composite beams with trapezoidal profiled metal decking laid perpendicular to the axis of the beam through experimental and numerical studies. Push tests are used to study the behaviour of composite beams. A three-dimensional …

    whiterose Download PDF for Finite element modelling of steel-concrete composite structures (opens in a new tab)

  7. Numerical Modelling and Analysis on Structural Behaviour of Composite Slim-Floor Beams

    … beams, includes investigation of push-out tests, shear beam tests, flexural beam tests. The most important result in this research includes two main parts. Part 1: Based on push out tests of shear connectors, FE model developed and validated, parameter study conducted, and a simple design …

    bradford Repository record for Numerical Modelling and Analysis on Structural Behaviour of Composite Slim-Floor Beams (opens in a new tab)

  8. Numerical modelling and development of design rules for novel demountable steelconcrete composite bridges

    … the structural behaviour of novel demountable shear connectors for steel-concrete composite bridges. Two shear connectors are investigated, namely locking-nut shear connector (LNSC) and friction-based shear connector (FBSC). The investigated shear connectors promote precast construction, and …

    soton Download PDF for Numerical modelling and development of design rules for novel demountable steelconcrete composite bridges (opens in a new tab)

  9. Testing and modifications of the beam-in-slab bridge system for use in short-span low-volume bridges

    … system and determine the acceptability of a new shear connector. The fourth segment consisted of fabrication and testing of a plain concrete arch using high density polyethylene (HDPE) pipe as formwork. This was done to determine its adequacy for use in a modified BISB. From this investigation it …

    iastate Repository record for Testing and modifications of the beam-in-slab bridge system for use in short-span low-volume bridges (opens in a new tab)

  10. Construction and Behavior of Precast Bridge Deck Panel Systems

    … of transverse joints, different types of shear connectors, and different shear pocket spacings. The bridge consisted of two AASHTO type II girders, 40 ft long and simply supported, and five precast bridge deck panels. Two of the transverse joints were epoxied male-female joints and the …

    vt Repository record for Construction and Behavior of Precast Bridge Deck Panel Systems (opens in a new tab)

  11. Analytical and experimental study of lightweight concrete-steel composite beams

    … behavior of composite beams. 2. The effect of shear connector spacing upon the behavior of composite beams. 3. The feasibility of using lightweight concrete in composite beams with the shear connection provided by headed stud type connectors. The method of attack was to develop first a …

    missouri Repository record for Analytical and experimental study of lightweight concrete-steel composite beams (opens in a new tab)

  12. Impact behaviour of steel-composite sandwich beams

    … of sandwich beams with different spacing of shear connector and concrete strength were evaluated under impact loading. Thin steel plates were used as top and bottom skins of the sandwich beams and plain concrete was used as the core material. Shear connectors were provided by welding of angle …

    nus Repository record for Impact behaviour of steel-composite sandwich beams (opens in a new tab) Download file for Impact behaviour of steel-composite sandwich beams (opens in a new tab)

  13. Elastic-plastic finite element modeling of long span composite joists with incomplete interaction

    … by modeling the nonlinear behavior of the steel shear connectors. Experimental tests on long span composite open-web steel joists were performed at Virginia Polytechnic Institute and State University. Measurements of joist deflections, member strains, and slip between the concrete slab and steel …

    vt Repository record for Elastic-plastic finite element modeling of long span composite joists with incomplete interaction (opens in a new tab)

  14. LIGHTWEIGHT STEEL FIBRE-REINFORCED CONCRETE COMPOSITE FLOOR SYSTEM FOR MODULAR BUILDINGS

    … connection was investigated and applied as a shear connector between the SFRC slab and the composite beam. Finally, a full-scale model of the composite beam-and-floor system for modular buildings was tested under four-point bending. It was found that the proposed floor system is capable of …

    nus Repository record for LIGHTWEIGHT STEEL FIBRE-REINFORCED CONCRETE COMPOSITE FLOOR SYSTEM FOR MODULAR BUILDINGS (opens in a new tab) Download file for LIGHTWEIGHT STEEL FIBRE-REINFORCED CONCRETE COMPOSITE FLOOR SYSTEM FOR MODULAR BUILDINGS (opens in a new tab)

  15. Analytical investigation of composite diaphragms strength and behavior

    … beam size and orientation, panel dimension, connector type and distance, slab opening, yield plateau, and beam connection flexibility. Shear connector, deck-to-concrete interface, and beam connection were the components modeled non-linearly. Orthotropic behavior was used for the deck …

    vt Repository record for Analytical investigation of composite diaphragms strength and behavior (opens in a new tab)

  16. BEHAVIOUR OF SLOTTED AND FLEXIBLE PERFOBOND RIB SHEAR CONNECTORS

    The perfobond rib connector is a new type of shear connector, first used in the construction of the Third Caroni bridge in Venezuela. Except for a limited number of proprietary tests conducted in Germany, research on perfobond rib shear connectors has been carried out mainly in Canada. Results of …

    sask Repository record for BEHAVIOUR OF SLOTTED AND FLEXIBLE PERFOBOND RIB SHEAR CONNECTORS (opens in a new tab)

  17. On Thermal Bowing of Concrete Sandwich Wall Panels with Flexible Shear Connectors

    … concrete layer thickness, panel length, type of shear connector and separation using a commercial finite element analysis software. This study concluded that current design practices either underestimate, in the case of multiplying the classical mechanics values by the reported degree of …

    utahstate Repository record for On Thermal Bowing of Concrete Sandwich Wall Panels with Flexible Shear Connectors (opens in a new tab)

  18. Shear Connections for the Development of a Full-Depth Precast Concrete Deck System

    … lacking design direction is the development of a shear connection between the full-depth precast deck and a precast concrete girder via a pocket-haunch-connector system. Push-off tests are performed to investigate the effects of various pre- and post-installed shear connectors, haunch height, …

    tamu Repository record for Shear Connections for the Development of a Full-Depth Precast Concrete Deck System (opens in a new tab)

Page 1 of 3