Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"Shear ratio"”.

  1. Seismic response of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars

    … flexural reinforcement type (steel and GFRP) and ratio (0.7 and 1.4%), the gravity shear ratio (0.4, 0.5, and 0.6), and the GFRP shear reinforcement type (shear studs and corrugated bars). In the analytical phase, models predicting the punching capacity of FRP-RC connections from literature were …

    manitoba Repository record for Seismic response of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars (opens in a new tab)

  2. Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections

    The two-way shear response of slab-column connections has been evaluated by a significant number of experiments. This research documents an updated database of slab-column (SC) connection tests using consistent criteria for selecting key response parameters including the limiting lateral drift …

    tamu Repository record for Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections (opens in a new tab)

  3. Instability, coherent structures and turbulent mixing in cross sheared flow in stratified environments

    … to turbulent flow commence from a perturbed shear flow without curved streamline, which having been theoretically assumed as a parallel shear flow. In Cartesian coordinates, the parallel shear flow satisfy V ≪U, where U and V represent the basic laminar flow velocity component in x and y …

    jamescook Download PDF for Instability, coherent structures and turbulent mixing in cross sheared flow in stratified environments (opens in a new tab)

  4. Response of Prestressed Concrete Plate-Edge Column Connections

    … subjected to static loadings in which both the shear and moment transferred between the slab and the column were increased proportionately until failure occurred. The specimens were models of the edge column and the surrounding slab area located within the negative moment area around the edge …

    uiuc Repository record for Response of Prestressed Concrete Plate-Edge Column Connections (opens in a new tab)

  5. Hybrid Members Employing FRP Skin Reinforcement for Beams and Cladding Wall Applications

    … terms of reproducibility of test results, moment-shear ratio, and the orientation of an architectural masonry-like coating. The study showed that design is governed by stiffness and not strength and that the CFRP was underutilized. Also, quality control was shown to be poor for this method of …

    queens Repository record for Hybrid Members Employing FRP Skin Reinforcement for Beams and Cladding Wall Applications (opens in a new tab)

  6. Punching shear behaviour of FRP-reinforced concrete interior slab-column connections

    … experimental phase were flexural reinforcement ratio, concrete compressive strength, type of the reinforcement, moment-to-shear ratio and the spacing between the shear stud reinforcement. Test results revealed that increasing the GFRP reinforcement ratio or the concrete strength increased the …

    manitoba Repository record for Punching shear behaviour of FRP-reinforced concrete interior slab-column connections (opens in a new tab)

  7. Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement

    This work deals with punching shear behaviour of flat plates reinforced with glass fibre-reinforced polymers (GFRP) reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural …

    manitoba Repository record for Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement (opens in a new tab)

  8. Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars

    … compared to steel bars which results in a lower shear capacity of FRP reinforced concrete (RC) elements compared to steel-RC elements. Flat plate systems are commonly used to take advantages of the absence of beams. They, however, are susceptible to punching shear failure where the column …

    manitoba Repository record for Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars (opens in a new tab)

  9. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  10. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  11. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  12. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  13. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  14. The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements

    Reinforced concrete elements designed without shear reinforcement are typical in retaining wall structures resisting hydrostatic and non-uniform soil pressures. Despite differing geometry, reinforcement proportions, and loading, these elements are designed using the same shear provisions as …

    tamu Repository record for The Effects of Linear-Varying Load on One-way Shear Strength of Retaining Wall-Type Elements (opens in a new tab) Embargoed until 2027-08-01

  15. Αντοχή και ικανότητα παραμόρφωσης μελών οπλισμένου σκυροδέματος, με ή χωρίς ενίσχυση

    … concrete elements performance under bending and shear, in terms of displacements. The object of the Thesis is development of models for calculating the basic performance characteristics of reinforced concrete elements under bending, in particular: yield moment, deformation at yielding, effective …

    greece Repository record for Αντοχή και ικανότητα παραμόρφωσης μελών οπλισμένου σκυροδέματος, με ή χωρίς ενίσχυση (opens in a new tab)

  16. Connections to concrete-filled steel tubes

    … included: the diameter-to-tube wall thickness ratio, the applied axial load on the column, the moment-to-shear ratio of the girder, and the yield strength of the steel tube. In the third phase of the research, six 2/3rd-scale specimens were fabricated and tested with the quasi-static method. …

    uiuc Repository record for Connections to concrete-filled steel tubes (opens in a new tab)

  17. Behaviour of GFRP-RC slab-column edge connections with openings

    … these systems are vulnerable to brittle punching shear failure, particularly in edge connections subjected to combined shear and unbalanced moment. The presence of slab openings near the column further disrupts load transfer, reduces the effective shear-resisting area and increases stress …

    manitoba Repository record for Behaviour of GFRP-RC slab-column edge connections with openings (opens in a new tab)

  18. Through bolt connections for composite columns

    … issue, mainly because the transfer of the beam shear to an axial load in the concrete core is not well understood. Friction is often relied upon to transfer loads although some design codes require direct bearing on the concrete. The development of an inexpensive connection which bears directly …

    ubc Repository record for Through bolt connections for composite columns (opens in a new tab) Download PDF for Through bolt connections for composite columns (opens in a new tab)

  19. Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing

    … prestress force, Pi, (ii) base moment to base shear ratio, and (iii) the number and location of additional hysteretic dampers in PreWECs, namely O-connectors.</p> <p>Minimal wall base damage was observed as these wall systems were subjected to the design-level ground motions. As intended, all …

    iastate Repository record for Seismic performance of unbonded post-tensioned precast wall systems subjected to shake table testing (opens in a new tab)

Page 1 of 2