Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 47 for “"Shear span-to-depth ratio"”
-
Strut action in columns subjected to seismic loading
… was tested under simulated seismic loading to study the effect of the shear span-to-depth ratio on the shear transfer mechanisms. The full size columns were identical in cross section and steel detailing, the only difference being the shear span-to-depth ratio, with ratios of 2.0, 2.5, and …
-
Shear strength of reinforced concrete beams.
… 1) percentage of longitudinal tension steel; 2) shear span to depth ratio. [...]
-
Shear Behaviour of Reinforced Concrete Deep Beams
… systems carrying heavy loads over short span, such as transfer girders in tall buildings and bridges. Current design provisions in codes of practice fail to predict accurately and reliably the shear capacity of RC deep beams and in some cases they are unsafe. This work aims to develop a …
-
Seismic performance of full-scale reinforced concrete columns
… However, little research has been conducted into the relationship among different ductility parameters. The objectives of this research are (1) to investigate the relationship among various ductility parameters by considering the effects of shear spanto-depth ratio and axial load level and (2) …
-
Shear behavior of reinforced concrete T-beams strengthened with carbon fiber reinforced polymer (CFRP) sheets and CFRP anchors
… objective of this research is the evaluation of shear behavior of full-scale reinforced concrete T-beams strengthened with carbon fiber reinforced polymer (CFRP) sheets and CFRP anchors. Although the CRFP material has high tensile strength, premature failure due to debonding CFRP sheets prevents …
-
Behaviour of corbels reinforced with headed-end GFRP bars
… Corbels are structural elements with low shear span-to-depth ratio that transfer vertical and horizontal loads to other members such as columns or walls. Given that the vast majority of RC infrastructure in North America is aging rapidly due to steel corrosion, engineers face the challenge …
-
Behaviour of concrete corbels reinforced with GFRP bent bars
… are used for load transfer from girders or slabs to columns. In North America, such elements are exposed to harsh weather, which makes them more susceptible to corrosion problems. This study focused on the behaviour and performance of reinforced concrete corbels using non-corrodible glass fibre …
-
Behaviour of GFRP-RC continuous deep beams without web reinforcement
… caps and pile caps, because of their capability to sustain higher loads compared to slender beams. In North America, such elements are exposed to harsh weather, which makes them more susceptible to corrosion problems. Thus, this study aims at investigating the feasibility and performance of using …
-
Shear Behaviour of Precast/Prestressed Hollow-Core Slabs
Shear strength of precast/prestressed hollow-core (PHC) slabs subjected to concentrated or line loads, especially near supports, may be critical and usually is the governing criteria in the design. This study presents the second phase of a research program, undergoing at the University of Manitoba, …
-
Structural Behaviour of Conventional and FRP- Reinforced Concrete Deep Beams
… behaviour of deep beams is affected by its span to depth ratio, type of loading, reinforcement ratio in vertical and horizontal directions, concrete strength, and type of cross section. Since the traditional beam theory is not applicable for designing deep beams, the strut and tie model …
-
Design for shear in reinforced concrete using strut-and-tie and sectional models
The design of reinforced concrete members for shear was studied. Both strut-and-tie models (STM) and sectional methods were examined. Initially, the response of isolated struts was observed. Various layout of reinforcement were used within the isolated struts. Three series of deep beam tests were …
-
Shear strengthening of reinforced concrete beams with carbon fiber reinforced polymer (CFRP) and improved anchor details
Fifteen tests were conducted to evaluate the shear performance of beams with carbon fiber reinforced polymer (CFRP) laminates and CFRP anchors. The specimens consisted of 24-in. deep T-beams. The specimens were strengthened in shear with CFRP laminates that were anchored using several different …
-
Influence of different parameters on shear strength of FRP reinforced concrete beams without web reinforcement
This research focuses on the shear behaviour of FRP reinforced concrete members without web reinforcement. The investigation was carried out in three phases, viz., experimental, analytical, and numerical simulation. The experimental investigation was carried out to investigate the effect of …
-
Prediction of Shear Strength of Reinforced Concrete Beams by Finite Element Method
… strength of reinforced concrete beams failing in shear. Nearly one hundred rectangular beams and a few T-beams were analysed. The beams analysed have been tested by various investigators covering the important variables such as : -a) Shear-span to depth ratio av/d. -b) Amount of shear …
-
Behavior of Non-Ductile Slender Reinforced Concrete Columns Retrofit by CFRP Under Cyclic Loading
… reinforced concrete (RC) columns are deemed to be weak in seismic resistance because of their low amount of reinforcement, low grades of concrete, and large spacing between the transverse reinforcement. The capacity of older RC columns that are also slender is further reduced due to the …
-
Design of reinforced concrete inverted-T beams for strength and serviceability
… of the problem prompted a more detailed look into the design and behavior of such structural components. Strut-and-tie modeling is currently recommended for design of deep (rectangular) beams, but its application to more complex structures has not been fully explored. Due to concerns with …
-
Experimental Investigation of Parameters Affecting Minimum Shear Reinforcement Requirements in Prestressed Concrete Girders
This study experimentally investigates minimum shear reinforcement requirements based on existing codes of practice and a parametric study of the factors affecting them. Minimum shear reinforcement requirements in the American Association of State Highway Transportation Officials (AASHTO) Load and …
-
Behaviour of continuously supported self-compacting concrete deep beams
The present research is conducted to investigate the structural behaviour of continuously supported deep beams made with SCC. A series of tests on eight reinforced two-span continuous deep beams made with SCC was performed. The main parameters investigated were the shear span-to-depth ratio, the …
-
Design criteria for strength and serviceability of inverted-T straddle bent caps
… bent caps and developing new design criteria to minimize such cracking in the future. Several tasks of the aforementioned project are addressed in this dissertation with particular focus on developing design criteria for strength and serviceability of inverted-T bent caps. Literature review …
Page 1 of 3