Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Shear tab connections"”

  1. Stability of Extended Shear Tab Connections Under Combined Loading

    Extended shear tab connections are efficient for both fabrication and erection where a beam would otherwise need to be coped to clear the flanges of the supporting member, and are therefore used extensively in industry. Stability issues can arise as the plate becomes longer and more slender, as may …

    alberta Repository record for Stability of Extended Shear Tab Connections Under Combined Loading (opens in a new tab)

  2. Non-Linear Finite Element Analysis of Extended Shear Tab Connections.

    … AISC14th Edition refers to an extended shear tab as a single plate shear connection. This method of providing simple connections has become quite popular with both fabricators and erectors. Extended shear tab connections were formally introduced in the 13th Edition of AISC Steel …

    ohiolink Repository record for Non-Linear Finite Element Analysis of Extended Shear Tab Connections. (opens in a new tab)

  3. Simplified modeling of shear tab connections in progressive collapse analysis of steel structures

    … is the behavior and performance of shear tab connections in steel structures during progressive collapse events. The shear tab, a simple connection, is typically modeled as a perfect pin in standard design, but in progressive collapse analysis, a much more accurate model of its true …

    texas Repository record for Simplified modeling of shear tab connections in progressive collapse analysis of steel structures (opens in a new tab)

  4. Moment-Rotation Curves for Shear Tab Connections Using Finite Element Modeling and Experimental Data

    … moment-rotation curves for "simple" gravity connections. In current design practice, the rotational stiffness of gravity connections is ignored to ease calculations and due to limited availability of data on the response of gravity connections to rotational demands. Research is presented that …

    ohiolink Repository record for Moment-Rotation Curves for Shear Tab Connections Using Finite Element Modeling and Experimental Data (opens in a new tab)

  5. A comparison of double clip angle shear connections to shear tab connections in industrial applications

    In structural steel connection design, simple shear connections are one of the most common connection types utilized. The industry, especially from the side of the engineer, tends to lean toward using Double Clip Angle Connections as the default standard for simple shear connections. A double clip …

    ksu Repository record for A comparison of double clip angle shear connections to shear tab connections in industrial applications (opens in a new tab)

  6. Effect of Shear Tab Connection on Lateral Torsional Buckling Capacity of W-Shape Beam

    Steel shear tab connections are one of the most common types of connections used to connect steel beam to supporting columns and girders. Shear tab connections can be of two types: conventional shear tab (CST) and extended shear tab (EST). In EST connection, the shear tab is generally extended …

    concordia

  7. Multi-hazard performance of steel moment frame buildings with collapse prevention systems in the central and eastern United States

    … deployed throughout the building, or enhanced shear tab connections, to provide adequate serviceability performance and collapse safety for seismic and wind hazards in the central and eastern United States. While the proposed concept is likely applicable to building structures of all materials, …

    vt Repository record for Multi-hazard performance of steel moment frame buildings with collapse prevention systems in the central and eastern United States (opens in a new tab)

  8. Study of the Influence of Gravity Connections on the Lateral Response of Steel-Concrete Composite Moment Frames

    … the design practice of steel buildings, moment connections have been considered as perfectly rigid for the purpose of resisting lateral loads with simple connections to resist gravity loads. Simple connections have been considered as perfectly pinned. Some research work with experimental tests …

    ohiolink Repository record for Study of the Influence of Gravity Connections on the Lateral Response of Steel-Concrete Composite Moment Frames (opens in a new tab)

  9. Design and Behaviour of Extended Shear Tabs under Combined Loads

    Current design procedures for extended shear tab connections tend to be conservative and often do not include considerations for axial load. To address these problems, an investigation into the behaviour of extended shear tabs was completed by testing 23 full-scale specimens. Both unstiffened and …

    alberta Repository record for Design and Behaviour of Extended Shear Tabs under Combined Loads (opens in a new tab)

  10. Modelling the Fire Performance of Hybrid Steel-Timber Connections

    … column is composed of three different types of shear tab connections: concealed, exposed and seated connections. The fire resistance of these connections is evaluated using a finite element model and compared with the full-scale experimental fire resistance tests which had been conducted earlier …

    carleton Repository record for Modelling the Fire Performance of Hybrid Steel-Timber Connections (opens in a new tab)

  11. Standardization and Testing of Embedded Plates for Design, Fabrication, and Construction Economy

    … or eight end-welded stud anchors, with design tables developed using CSA A23.3:19, are proposed through collaboration with industry partners involved in the construction process. A small number of plate configurations were chosen to cover a wide variety of common placement and loading …

    alberta Repository record for Standardization and Testing of Embedded Plates for Design, Fabrication, and Construction Economy (opens in a new tab)