Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 54 for “"Shift Factor"”
-
Time-temperature shift factor determination of woven epoxy laminate using dynamic mechanical analyzer (DMA)
… master curves of storage moduli and horizontal shift factors for both specimens. It was concluded that the effect of frequency scan resulted in an earlier transition and it registered a greater deterioration of the storage modulus than the experiment which was conducted with temperature scan at …
-
Topology control algorithms in power systems
… for production cost reduction based on a shift factor (SF) representation of branch and breaker flows is proposed. The framework models topology changes endogenously while maintaining linearity in the overall Mixed Integer Linear Programming (MILP) formulation. This work develops the DC …
-
Utilization of Instrument Response of SuperPaveTM Mixes at the Virginia Smart Road to Calibrate Laboratory Developed Fatigue Equations
… typically accounted for by the use of a single shift factor based mainly on engineering experience. The flexible pavement portion of the Virginia Smart Road includes 12 different flexible pavement designs. Each section is approximately 100m long. The sections are instrumented with pressure …
-
Rheology of molten polystyrene with dissolved gases
… decrease in viscosity. The composition-dependent shift factor scaling method, which is similar to classical viscoelastic scaling techniques (time-temperature superposition), was adopted in order to evaluate the effect of gas concentration on viscosity. The method successfully consolidates the …
-
Volume-induced stress response in amorphous polymers
… considerable flexibility in adjusting the shift factor for the glassy state.</p> <p>The data of the present work came from measuring the stress build-up in a uniaxially constrained fiber, subjected to cooling rates varying from 0.08 to 3.2 <i>°C/sec</i>. The volume contraction was …
-
A finite element analysis of adhesively bonded composite joints including geometric nonlinearity, nonlinear viscoelasticity, moisture diffusion and delayed failure
… response is taken into account by a nonlinear shift factor definition. Penetrant sorption is accounted for by a nonlinear Fickean diffusion model in which the diffusion coefficient is dependent on the penetrant concentration and the dilatational strain. A delayed failure criterion based on the …
-
Effect of pressure on the rheological properties of three polyethylenes
… and it was found that the pressure data could be shifted onto the ambient pressure curves by means of a pressure shift factor. The viscosity increases exponentially with pressure. Long chain branching increases the pressure sensitivity, but the polydispersity has little effect. The effect of …
-
Viscoelastic characterization of polyurea based polymers
… in the form of Prony series. The thermal shift factor for bulk relaxation was fitted with the Arrhenius equation while for shear relaxation, the trend was fitted with the WLF equation. The nonlinear response at ambient conditions was predicted using the modified free volume model (Park et …
-
Development of tension and compression creep models for wood using the time-temperature superposition principle
… creep compliance for each temperature was shifted along the log-time axis to obtain a "master" curve that describes the creep response of the specimens. All compliance curves also required vertical shifting. The experimental horizontal shift factors followed the Arrhenius formulation that …
-
EFFECT OF HYDRATION ON THE MECHANICAL PROPERTIES OF A PVA DUAL-CROSSLINKED HYDROGEL
… us overestimate the dynamic modulus and give a shift factor for different compression.
-
Measuring and predicting sealant adhesion
… humidity is less than 35%. The temperature shift factor was not related to the WLF theory but worked well with an Arrhenius theory. The activation energy for the fracture process was 31.2 kcal/mol. Crack growth data for an expansion joint was calculated for the weather conditions in Miami, …
-
MODELLING THE RHEOLOGY OF COMPLEX FLUIDS : Cases of Bitumen and Heavy Oils at low temperatures.
… history of these fluids and a temperature shift factor aTP that integrates the thermal history, through the usage of the concept of fictive temperature Teff inside a modified Williams Landel Ferry (WLF) equation. Rheological data for the feedstocks were divided into a training data set, …
-
Correlation between master curves obtained from rheology and mechanical testing
… tests and rheometer. The aim was to compare the shift factors and master curves. At first, under certain frequency and temperature range the master curve was generated by rheometer. After that, shift factors and complex modulus were calculated. On the other hand, stress relaxation tests were …
-
Durability Performance Of Geopolymer Concrete Beams And Columns Exposed To Hygrothermal Environment
… (WLF) equation was employed here to develop the shift factor for regular concrete and geo-polymer concrete exposed to different environmental conditions. The shift factors were determined empirically based on experimental test results. To confirm the validity of the analysis process and the …
-
The Role of Penetrant Structure on the Transport and Mechanical Properties of a Thermoset Adhesive
… variables. The concept of a diffusion-time shift factor (log aDt) has been introduced to create doubly-reduced master curves, taking into account the effects of temperature and the variations in the polymer mechanical response due to the existence of a low molecular weight penetrant.
-
A measurement of complex viscosity with large amplitudes
… and η only have similar shapes. η' and η can be shifted into coincidence along the γ - Ω axis with shift factor of 2. The dependence of complex viscosity on amplitude was investigated for the 5 g/dl PIB L-80 solution. Both η' and η" decrease with increasing amplitude when amplitude is beyond a …
-
Modeling of the linear viscoelastic response of polymer modified asphalt binders at intermediate and high temperatures
… engineering problems was presented. The measured shift factor data was used to study the dependency of the viscoelastic response on temperature variations. It was observed that this dependency is dominated by the asphalt phase. Within the studied range of temperatures, the WLF equation with …
-
Fatigue Behavior and Modeling of Short Fiber Reinforced Polymer Composites
… on tensile strength. A temperature dependent shift factor of Arrhenius type is suggested, which is independent of the mold flow direction. Variation of tensile toughness with fiber orientation and strain rate was evaluated and mechanisms of failure were identified based on fracture surface …
-
Durability of woven composite structures
… includes: determining the time-temperature shift factor, storage modulus master curve, constant strain rate (CSR) strength master curve, zero stress ratio fatigue strength master curve and fatigue strength at arbitrary load ratio, temperature and frequency for both tensile and shear …