  1. Automated methods for gradient and shim coil design for magnetic resonance imaging

    The design of gradient and shim coils for MR imaging, as central hardware components for <br>signal encoding and thus image generation, is a complex and time-consuming engineering task. From the choice of support geometry to the optimization of current density to the preparation of the final, …

    freiburg-diss Repository record for Automated methods for gradient and shim coil design for magnetic resonance imaging (opens in a new tab)

  2. Improved magnetic resonance chemical shift imaging at 3 Tesla using a 32-channel integrated RF-shim coil array

    … introduced, novel, 32-channel integrated RF-shim coil hardware. Experimental results indeed demonstrate sharper spectral lines with narrower line widths and improved water suppression performance in the regions with poor BO conditions with the application of the shim coil hardware.

    mit Repository record for Improved magnetic resonance chemical shift imaging at 3 Tesla using a 32-channel integrated RF-shim coil array (opens in a new tab)

  3. Pushing the Boundaries in Gradient and Shim Design for MRI

    High performance gradient and shim coils are highly interested for high-field magnetic resonance imaging and spectroscopy to correct for large B0 inhomogeneities created by the magnetic susceptibility differences between tissues, bone, and air. In chapter two, complete sets of high-performance …

    uwo Repository record for Pushing the Boundaries in Gradient and Shim Design for MRI (opens in a new tab)

  4. THREE INITIATIVES ADDRESSING MRI PROBLEMS

    … acquisition time and reconstruction time.A shim coil is designed to cancel the susceptibility-induced field inhomogeneities at the back of the knee. The current density of the shim coil is inversely calculated using a target-field approach. The resulting field inhomogeneities can be reduced …

    ohiolink Repository record for THREE INITIATIVES ADDRESSING MRI PROBLEMS (opens in a new tab)

  5. Optimization and construction of passive shim coils for human brain at high field MRI

    … such as image distortion and signal loss. Active shimming improves homogeneity by applying corrective fields generated from shim coils, but requires calculation of optimal current for each shim coil. In chapter two, we discuss the computation of the calibration table to generate optimal active …

    ohiolink Repository record for Optimization and construction of passive shim coils for human brain at high field MRI (opens in a new tab)

  6. Optimization of a boundary element approach to electromagnet design with application to a host of current problems in Magnetic Resonance Imaging

    … predominantly addresses gradient and shim coil design (sub-systems of the MR system). A design study to investigate gradient performance over a set of surface geometries ranging in curvature from planar to a full cylinder using the boundary element (BE) method is presented. The results …

    uwo Repository record for Optimization of a boundary element approach to electromagnet design with application to a host of current problems in Magnetic Resonance Imaging (opens in a new tab)

  7. A Medical Physics Chronicle In Three Acts: Machine Learning In Radiation Oncology; Designing RF Shim Coils In MRI; New Partial Volume Analysis In MRF.

    … and develop a prototype single half-cylinder shim coil for knee MRI and investigate its limits. In vivo data show that our method, which is based on Turner’s target field for coil design, could be optimized to mitigate B0 non-uniformity in localized regions of interest.Magnetic Resonance …

    ohiolink Repository record for A Medical Physics Chronicle In Three Acts: Machine Learning In Radiation Oncology; Designing RF Shim Coils In MRI; New Partial Volume Analysis In MRF. (opens in a new tab)

  8. High power systems for dynamic field control and shielding in the MR environment

    … thesis addresses several aspects of gradient and shim coil design and fabrication. New design techniques are coupled with experimental construction methods to expand small animal insert gradient and shim technology. The design techniques are also applied to other areas of magnetic resonance …

    uwo Repository record for High power systems for dynamic field control and shielding in the MR environment (opens in a new tab)

  9. Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength

    … Clinical MR scanners are equipped with basic shim systems to correct for occurring B0-field inhomogeneities and resulting image artifacts, however, these are not sufficient for the advanced measurement techniques employed for ultra-high field MRI of the heart. Therefore, this work focused on …

    wurz-thes Repository record for Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength (opens in a new tab)

  10. Design and Construction of a Longitudinally Polarized Solid Nuclear Target for CLAS12

    … system, superconducting magnetic correction coils, and an all new bespoke NMR (Nuclear Magnetic Resonance) system. In addition to a detailed description of the complete target system and an initial report of the RGC experimental run, it will also present a study of Quark-Hadron Duality in the …

    odu Repository record for Design and Construction of a Longitudinally Polarized Solid Nuclear Target for CLAS12 (opens in a new tab)

  11. Magnetic Resonance Systems Development for Point-of-Care MRI Platforms

    … is overcome by designing asymmetric gradient coils which have their imaging region located towards one end of the gradient coil, as opposed to the geometric center, allowing brain imaging. There exists interest in compact configurations which allow imaging further into the cervical spine which …

    uwo Repository record for Magnetic Resonance Systems Development for Point-of-Care MRI Platforms (opens in a new tab)

  12. Static field shimming in the human brain for ultra-high field MRI : conceptual limits and development of a novel hardware prototype

    … Ce processus, connu sous le nom de shimming, est généralement effectué avec des bobines corrigeant les harmoniques sphériques (SH) du champ jusqu'au troisième degré, mais la correction fournie par l'ensemble des bobines de ce degré devrait être insuffisante à 11,7T. Pour augmenter …

    star-france Repository record for Static field shimming in the human brain for ultra-high field MRI : conceptual limits and development of a novel hardware prototype (opens in a new tab)