Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 4 of 4 for “"Short dental implants"”.

  1. Short dental implants in maxillary sinus augmentation sites: a preliminary study.

    … retrospective study is to evaluate the number of short-plateau design dental implants, 8 mm or less in length, in maxillary sinus augmented sites with either an internal sinus lift procedure or a sinus transport procedure with or without bone grafting. Materials and Methods: A retrospective chart …

    umn Repository record for Short dental implants in maxillary sinus augmentation sites: a preliminary study. (opens in a new tab)

  2. Short Implants (6mm) Versus Longer Implants (11mm) in Combination With Sinus Elevation Procedure in the Atrophic Maxilla: Retrospective Analysis of a 5 Year Follow Up of a Randomized Clinical Trial

    AIM: To compare, clinically and radiographically, short dental implants (6 mm) to long implants (11-15 mm) placed with sinus grafting. METHODS: Participants with 5-7 mm of bone height in the posterior maxilla were randomly allocated to receive short implants (GS) or long implants with sinus …

    uconn-diss Repository record for Short Implants (6mm) Versus Longer Implants (11mm) in Combination With Sinus Elevation Procedure in the Atrophic Maxilla: Retrospective Analysis of a 5 Year Follow Up of a Randomized Clinical Trial (opens in a new tab)

  3. Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis

    Statement of problem: The use of short dental implants is usually confined to areas of the mouth with limited vertical bone height. As a result, longer implant crowns are required to restore the occlusion with the opposing arch, leading to a disproportionate crown-to-implant ratio (C/I ratio). …

    umn Repository record for Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis (opens in a new tab)

  4. INFLUENCE OF IMPLANT NUMBER, IMPLANT LENGTH AND CROWN HEIGHT ON BONE STRESS DISTRIBUTION FOR THREE-UNIT BRIDGES IN THE POSTERIOR MANDIBLE: A 3D FINITE ELEMENT ANALYSIS.

    … represents a major limitation in the use of dental implants, in particular in the posterior sectors of jaws. It increases the probability of an invasion with related possible damage to some anatomical structures, such as the inferior alveolar nerve. Short dental implants' placement has been …

    milano Repository record for INFLUENCE OF IMPLANT NUMBER, IMPLANT LENGTH AND CROWN HEIGHT ON BONE STRESS DISTRIBUTION FOR THREE-UNIT BRIDGES IN THE POSTERIOR MANDIBLE: A 3D FINITE ELEMENT ANALYSIS. (opens in a new tab)