Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 110 for “"SiPM"”.

  1. Development of ASIC for SiPM sensor readout

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Development of ASIC for SiPM sensor readout (opens in a new tab)

  2. FPGA-based Data Acquisition System for SiPM Detectors

    … is a must. Within this work, an FPGA based SiPM DAQ is presented with emphasis regarding the application of PET imaging. An introduction concerning PET concepts is included with a brief description of measurement techniques followed by a review of previous work with a detailed explanation of …

    houston Repository record for FPGA-based Data Acquisition System for SiPM Detectors (opens in a new tab)

  3. Next generation SiPM characterization and modeling for ARGO

    … higher radiopurity, Silicon PhotoMultipliers (SiPMs) are increasingly considered in these experiments over PhotoMultiplier Tubes (PMTs) to measure the scintillation light produced in particle interactions within the liquid argon detectors used. The development of passively quenched, analogue …

    ubc Repository record for Next generation SiPM characterization and modeling for ARGO (opens in a new tab) Download PDF for Next generation SiPM characterization and modeling for ARGO (opens in a new tab)

  4. SiPM Arrays as Readouts for the GlueX Barrel Calorimeter

    The GlueX experiment at Je erson Lab seeks to map out gluonic degrees of freedom in order to gain a better understanding of gluons and their interactions with quarks towards elucidating the phenomenon of con nement in Quantum Chromodynamics. In order to accomplish this goal the experiment must be …

    regina Repository record for SiPM Arrays as Readouts for the GlueX Barrel Calorimeter (opens in a new tab) Download PDF for SiPM Arrays as Readouts for the GlueX Barrel Calorimeter (opens in a new tab)

  5. Low-Power Mixed-Signal ASIC for Cryogenic SiPM Readout

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Low-Power Mixed-Signal ASIC for Cryogenic SiPM Readout (opens in a new tab)

  6. A Bulk Driven Transimpedance CMOS Amplifier for SiPM Based Detection

    … />power. Silicon photomultipliers, also known as SiPMs, when coupled with scintillator materials are used in many imaging applications including nuclear detection. This thesis discuss the design of a bulk-driven transimpedance amplifier suitable for detectors where the front end is a SiPM. The …

    ut-knoxville Repository record for A Bulk Driven Transimpedance CMOS Amplifier for SiPM Based Detection (opens in a new tab)

  7. A novel high-efficiency SiPM-based system for Ps-TOF

    … is proposed, using Silicon Photomultipliers (SiPMs) instead of Photomultiplier Tubes. The solution allows us to dramatically increase the compactness of the set up, thus improving the efficiency of 240%. Different configurations of SiPM+scintillators are characterized in order to find the best …

    trento Repository record for A novel high-efficiency SiPM-based system for Ps-TOF (opens in a new tab) Restricted access

  8. Highly Integrated CMOS Interface Circuits for SiPM Based PET Imaging Systems

    … (PET) detectors using Silicon Photomultipliers (SiPMs) have demonstrated the feasibility of higher resolution PET scanners due to a significant reduction in the detector form factor. However, reduced size implies a corresponding increase in the detector density, resulting in a proportional rise …

    washington Repository record for Highly Integrated CMOS Interface Circuits for SiPM Based PET Imaging Systems (opens in a new tab)

  9. Modeling, Design and Characterization of a Multi-Pixel Digital SiPM for PET Applications

    Positron Emission Tomography (PET) scanners provide functional three-dimensional images of the body that are extremely useful in cancer and brain research. The goal of this work is the modeling, design and characterization of a CMOS-based photodetector for PET. To this aim, first a model for the …

    trento Repository record for Modeling, Design and Characterization of a Multi-Pixel Digital SiPM for PET Applications (opens in a new tab)

  10. High-Performance CMOS Front-End ASICs for SiPM Detectors and High-Frequency Ultrasound and Photoacoustic Imaging

    Silicon photomultiplier (SiPM), as a high sensitivity photon detector, has been widely used in high energy physics, positron emission tomography imaging, and light detection and ranging applications. The slow-rising edge of standard SiPM signal, however, makes the timing measurement sensitive to …

    houston Repository record for High-Performance CMOS Front-End ASICs for SiPM Detectors and High-Frequency Ultrasound and Photoacoustic Imaging (opens in a new tab)

  11. Quasi-Background-Free Neutrinoless Double-Beta Decay Searches with LEGEND: Statistical Methods and Cryogenic SiPM Characterization

    … light in its silicon photomultiplier (SiPM) readout as possible. The detection efficiency of the liquid argon system is directly proportional to the photon detection efficiency (PDE) of the SiPMs. The PDE is a well-known quantity reported by the manufacturer, at room temperature; …

    washington Repository record for Quasi-Background-Free Neutrinoless Double-Beta Decay Searches with LEGEND: Statistical Methods and Cryogenic SiPM Characterization (opens in a new tab)

  12. CRYOGENIC DETECTION OF SCINTILLATION LIGHT WITH LARGE AREA SIPM ARRAYS FOR NEXT GENERATION NEUTRINO AND DARK MATTER EXPERIMENTS

    … copper cables. To bias silicon photomultipliers (SiPM) in such environment, a novel DC-DC boost converter working in cryogenics was designed. First, a proof-of-concept prototype was tested and characterized at liquid nitrogen temperature, then a full prototype integrated with the DUNE electronics …

    milano Repository record for CRYOGENIC DETECTION OF SCINTILLATION LIGHT WITH LARGE AREA SIPM ARRAYS FOR NEXT GENERATION NEUTRINO AND DARK MATTER EXPERIMENTS (opens in a new tab)

  13. Silicon photomultipliers as optical wireless receivers in ambient light

    … Receivers based upon silicon photomultipliers (SiPMs) have been shown to be more sensitive than other VLC receivers, for on-off keying (OOK) data rates less than 1.5 Gbps. Despite having the ability to detect individual photons, one of the major issues in using a SiPM as a receiver is device …

    oxford Repository record for Silicon photomultipliers as optical wireless receivers in ambient light (opens in a new tab)

  14. Testing the Benefits of Using Silicon Photomultipliers on Organic Scintillator Portal Monitors

    … capabilities is using Silicon Photomultipliers (SiPMs) on the organic scintillation panels used at checkpoints to detect radiation. Research on SiPMs has been relegated to small detectors with volumes in the cubic millimeter range, but large portal monitors are often used at ports of entry and …

    tamu Repository record for Testing the Benefits of Using Silicon Photomultipliers on Organic Scintillator Portal Monitors (opens in a new tab)

  15. Development of a high-resolution, MRI-compatible PET detector using digital silicon photomultipliers

    … a novel photodetector, the so-called digital SiPM, was presented. The digital SiPM combines an array of Geiger-mode photodiodes with a direct digital readout and timestamper on a single silicon die. Its high integration and expected immunity to magnetic fields makes the digital SiPM very …

    kings Repository record for Development of a high-resolution, MRI-compatible PET detector using digital silicon photomultipliers (opens in a new tab) Download PDF for Development of a high-resolution, MRI-compatible PET detector using digital silicon photomultipliers (opens in a new tab)

  16. Progettazione, sviluppo e trasferimento tecnologico: Un'esplorazione completa dei calorimetri a doppia lettura basati su SiPM per i futuri collisori circolari e la loro applicazione per il monitoraggio della qualità dell'acqua nello spettro UV-Vis.

    … e HiDRa, e sui test estensivi di una matrice SiPM di Hamamatsu a varie temperature, che sono culminati nella messa a punto di un impianto di qualificazione di massa per SiPM. La seconda parte prevede il trasferimento della tecnologia SiPM alla fisica ambientale per il monitoraggio online della …

    catania Repository record for Progettazione, sviluppo e trasferimento tecnologico: Un'esplorazione completa dei calorimetri a doppia lettura basati su SiPM per i futuri collisori circolari e la loro applicazione per il monitoraggio della qualità dell'acqua nello spettro UV-Vis. (opens in a new tab)

  17. CMOS Silicon Photomultiplier using PerimeterGated Single Photon Avalanche Diode

    … and astrophysics. Since silicon photmultipliers (SiPMs) are relatively insusceptible to magnetic fields, compact, and require relatively lower bias voltages, they have been aroused interests and showing a great potential as a substitute to photomultiplier tubes (PMTs). SiPM consists of a large …

    utk-theses Repository record for CMOS Silicon Photomultiplier using PerimeterGated Single Photon Avalanche Diode (opens in a new tab)

Page 1 of 6