Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 41 for “"Side branch"”

  1. Characteristic behavior of a side branch in a dendritic crystal growth

    <p>This study investigates the characteristic behavior of disturbances on the interface of a needle crystal, Ivantsove parabola, based on an asymptotic analysis as well as a numerical study.</p><p>Focusing on tip growth and width behavior, we examine anisotropy in surface energy, initial strength …

    ohiolink Repository record for Characteristic behavior of a side branch in a dendritic crystal growth (opens in a new tab)

  2. Methods for predicting the influence of intense sound, steady flow, and elevated temperature on the acoustic performance of automotive exhaust system components

    … studies of typical acoustic elements (side-branch resonators, expansion chambers, louvered tubes) used in muffler design. The sound fields used for these studies included pure tones, single pulses (tone bursts), random noise, and simulated automobile exhaust noise. Empirical correction …

    must-thes Repository record for Methods for predicting the influence of intense sound, steady flow, and elevated temperature on the acoustic performance of automotive exhaust system components (opens in a new tab)

  3. Total endovascular therapy of aortoiliac aneurysms with preservation of internal iliac artery patency using Iliac Branch Device (Zenith® Branch, COOK MEDICAL INCORPORATED)

    … treatment of aortoiliac aneurysms was considered to be limited. This study shows that the indication for endovascular therapy (EVAR) of aortoiliac aneurysms (AIA) is broadened by using iliac side-branch device (Zenith bifurcated iliac side-branch ZBIS, COOK). The study presents a …

    fu-berlin Repository record for Total endovascular therapy of aortoiliac aneurysms with preservation of internal iliac artery patency using Iliac Branch Device (Zenith® Branch, COOK MEDICAL INCORPORATED) (opens in a new tab)

  4. Estudo de modos acústicos em ramificação de duto cilíndrico utilizando funções de Green

    … of coupling between different modes in a side-branch of a hard walled duct. A convected wave equation for the pressure flutuation, including viscosity effects is developed. The Green function for the wave operator is obtained in the frequency domain. An expression for the interaction of …

    brazil-uerj Repository record for Estudo de modos acústicos em ramificação de duto cilíndrico utilizando funções de Green (opens in a new tab)

  5. EXPERIMENTAL AND COMPUTATIONAL STUDY ON THE EFFECTS OF FLOW DISRUPTIONS CAUSED BY STENTING AND IT’S IMPACT ON ACUTE STENT THROMBOSIS

    … dedicated stent design and opening the side branch reduced acute stent thrombogenicity. No significant difference in acute thrombogenicity was observed between a main branch first and side branch first bifurcation double stenting technique. Computational fluid dynamic models created …

    nus Repository record for EXPERIMENTAL AND COMPUTATIONAL STUDY ON THE EFFECTS OF FLOW DISRUPTIONS CAUSED BY STENTING AND IT’S IMPACT ON ACUTE STENT THROMBOSIS (opens in a new tab)

  6. Investigations of acoustically-coupled shear layers using particle image velocimetry

    … flow past a coaxial deep cavity (side branch) resonator mounted in a duct. The emphasis is on the effect of the separation between the coaxial side branches on the interaction between separated shear layers that form across the side branch openings. Various resonator geometries are …

    uvic Repository record for Investigations of acoustically-coupled shear layers using particle image velocimetry (opens in a new tab)

  7. INVESTIGATION OF ACOUSTIC ATTENUATION METHODS AS A NOISE CONTROL DEVICE IN HYDRAULICS

    … throughout testing. Three methods known as side branch resonators, Herschel-Quincke tubes, and simple expansion muffler methods all use vibroacoustic attenuation and have been tested and validated on this test bench to better understand the attenuation properties. With this data, these …

    mtu Repository record for INVESTIGATION OF ACOUSTIC ATTENUATION METHODS AS A NOISE CONTROL DEVICE IN HYDRAULICS (opens in a new tab)

  8. Experimental and computational investigation of the mechanisms behind deep vein thrombosis

    … to see if the amount of stenosis and presence of side branches influenced flow. I was determined that the influence of a restriction did not alter the flow enough to encourage thrombus formation, however the stenosis would increase the number of cell-cell collisions which could be the reason for a …

    birmingham Repository record for Experimental and computational investigation of the mechanisms behind deep vein thrombosis (opens in a new tab)

  9. Effect of Step Change in Growth Speed During Directional Solidification on Array Morphology of Al-7 wt% Si Alloy

    … spacing, primary dendrite trunk diameter, side (secondary dendrite) branch length and side branch orientation, have been characterized in to investigate the transients introduced by step increase and step decrease in growth speed. </p><p>An increase in the growth speed shows a decrease in …

    ohiolink Repository record for Effect of Step Change in Growth Speed During Directional Solidification on Array Morphology of Al-7 wt% Si Alloy (opens in a new tab)

  10. Impact of different stenting techniques on the blood flow within the peripheral artery bifurcation

    … common stenting techniques i.e. “Provisional side branch (PSB), Culotte (CUL), Crush (CRU) and Standard T techniques under pulsatile flow condition. This has been investigated considering the effect of meshing, oversize ratio and the main branch stent of appropriate size. The results obtained …

    unsw Repository record for Impact of different stenting techniques on the blood flow within the peripheral artery bifurcation (opens in a new tab)

  11. Flow-induced sound and vibration due to the separated shear layer in backward-facing step and cavity configurations

    Fully turbulent inflow past symmetrically located side branches mounted in a duct can give rise to pronounced flow oscillations due to coupling between separated shear layers and standing acoustic waves. Experimental investigation of acoustically-coupled flows was conducted using digital particle …

    uvic Repository record for Flow-induced sound and vibration due to the separated shear layer in backward-facing step and cavity configurations (opens in a new tab)

  12. Quantifying Hemodynamic Changes Caused by Stenting of Coronary Bifurcation Lesions Using Realistic Computational Fluid Dynamics Models

    … Interestingly, CAD often localizes at bends, branches and bifurcations throughout the vasculature. Stenting is the preferred treatment for CAD and has been applied to coronary bifurcation lesions with limited success due to high levels of restenosis. Hemodynamic parameters including …

    marquette Repository record for Quantifying Hemodynamic Changes Caused by Stenting of Coronary Bifurcation Lesions Using Realistic Computational Fluid Dynamics Models (opens in a new tab)

  13. Συγκριτική μελέτη της απόπτωσης του τοιχώματος των φλεβών των κάτω άκρων σε υγιείς ,σε ασθενείς με κιρσούς και σε ασθενείς με θρόμβωση κιρσών

    … part of the vein and a specimen of a varicose side branch were used as a means of immunohistochemically localizing the expression of BAX, P53, Caspase 3, BCL-2, BCL-6, BCLxs, BCLxl and Ki-67. Vein specimens from 10 healthy greater saphenous veins were used as controls. Statistical analyses were …

    greece Repository record for Συγκριτική μελέτη της απόπτωσης του τοιχώματος των φλεβών των κάτω άκρων σε υγιείς ,σε ασθενείς με κιρσούς και σε ασθενείς με θρόμβωση κιρσών (opens in a new tab)

  14. Effects of the geometric modifications on the shear layer excitation source in co-axial side branches

    … the aeroacoustic resonance of a coaxial side branch and the resultant peak acoustic pressure and the sound source term. Interestingly, edge geometry modification, specifically edge rounding and chamfering, plays a crucial role in the phasing of the shear layer with the acoustic field, …

    uoit Repository record for Effects of the geometric modifications on the shear layer excitation source in co-axial side branches (opens in a new tab)

  15. Active, Passive and Active/Passive Control Techniques For Reduction of Vibrational Power Flow in Fluid Filled Pipes

    … rig. Active control experiments using the side-branch actuator and 1/3 piezoelectric composite yielded significant dB reductions revealing their potential for practical applications. A combined active/passive approach was also implemented as part of this work. This approach yielded …

    vt Repository record for Active, Passive and Active/Passive Control Techniques For Reduction of Vibrational Power Flow in Fluid Filled Pipes (opens in a new tab)

  16. Morphogenesis in the moss physcomitrella patens

    … chloronema to caulonema, and the development of side-branches were obtained. Filaments were found to undergo the transition to caulonema earlier than previously thought. The majority of caulonemas ide-branches were found to begin as chloronema and switch to caulonema after one or two cell cycles. …

    whiterose Repository record for Morphogenesis in the moss physcomitrella patens (opens in a new tab)

Page 1 of 3