Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"Siemens Oncor"”

  1. Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation

    … was used to measure the neutron fluence from the Siemens Oncor linear accelerator. Measurements were made both in the photon beam and in peripheral locations using 20x20cm jaw settings. The head leakage was measured as well, with the jaws closed as is prescribed in AAPM report 19. The neutron …

    ohiolink Repository record for Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation (opens in a new tab)

  2. Computational modeling of neutron production by a Siemens Oncor Linac and benchmarked by experimental data

    … potential uses. Modeling results show that a Siemens Oncor electron driven accelerator fitted with an x-ray (heavy metal) converter can produce a thermal neutron flux of 1.33E5 neutrons/cm2/sec in a 1 liter beaker of heavy water 76.37 cm away from the beam source. When irradiating a square …

    missouri Repository record for Computational modeling of neutron production by a Siemens Oncor Linac and benchmarked by experimental data (opens in a new tab)

  3. Die Bedeutung des Unterschiedes zwischen den angewandten Photonenenergien 6 MV und 18 MV bei der Bestrahlung von Blut am Linearbeschleuniger

    … XiO für den Linearbeschleuniger Siemens ONCOR Anvant-Garde berechnet wurde. Ergebnisse: In beiden durchgeführten Messanordnungen (Blutbeutelphantom und Erythrozytenkonzentrat) ließ sich induzierte Radioaktivität für 18 MV nachweisen - nicht jedoch für 6 MV. Die gemessene …

    fu-berlin Repository record for Die Bedeutung des Unterschiedes zwischen den angewandten Photonenenergien 6 MV und 18 MV bei der Bestrahlung von Blut am Linearbeschleuniger (opens in a new tab)

  4. Nanoparticle-mediated Assessment of ROS and Radiosensitization of Brain Cancer Cells for Improved Radiotherapy Outcomes

    … a compact Faxitron Cell Irradiator and clinical Siemens Oncor linear accelerator (LINAC), we irradiated U87 and T98G glioblastoma derived cells inoculated with nanoparticles and measured their migratory behavior and quantum dot fluorescence intensity. Cell attachment, migration, and proliferation …

    creighton Repository record for Nanoparticle-mediated Assessment of ROS and Radiosensitization of Brain Cancer Cells for Improved Radiotherapy Outcomes (opens in a new tab)

  5. Evaluación de la cobertura dosimétrica tumoral en tratamientos radioterápicos de cáncer de pulmón

    … los elementos del cabezal del acelerador lineal Siemens Oncor Impression Plus, instalado en el Hospital Universitario Virgen Macarena (Sevilla, España), a través de la comparativa con medidas experimentales efectuadas con cámara de ionización en agua. Junto a ello, hemos constatado las …

    sevilla Repository record for Evaluación de la cobertura dosimétrica tumoral en tratamientos radioterápicos de cáncer de pulmón (opens in a new tab)

  6. Investigations of radiation shielding, diagnostic methods and imaging for conventional and laser-driven radiation sources

    … distributions and lateral field profiles of a Siemens ONCOR medical electron linac. This well defined electron source together with measurements of the electron fields helped to identify the radiation-induced measurement background in the magnetic spectrometer. In a following step, a MC based …

    lmu-germany Repository record for Investigations of radiation shielding, diagnostic methods and imaging for conventional and laser-driven radiation sources (opens in a new tab)