Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"Silicon diode"”
-
A silicon-diode-bridge parametric amplifier for low frequencies
The varactor properties of silicon—diode rectifiers in the low-frequency region are investigated. A theoretical analysis of a two-diode bridge is made, and the results experimentally verified using a matched pair of these diodes and a pump frequency of 455 Kc. The theoretical transducer power gain …
-
IMPATT diode amplifier.
A high performance IMPATT diode test circuit has been developed which is very effective in reducing spurious oscillations of the diode under test by controlling the impedance presented to the diode by the circuit. In this circuit, a 10 GHz silicon diode has been tested as an amplifier with power …
-
Development of the Atmospheric Ionizing Radiation Tissue Equivalent Dosimeter
… equivalent proportional counter (TEPC) and a silicon PIN diode, respectively. A novel TEPC detector head was developed to minimize microphonic noise, alongside custom analog signal processing circuits and PCBs. A Red Pitaya single-board computer was fully implemented as a spectrometer. AirTED …
-
Development of an X-ray spectrometric system and feasibility tests of Silicon Drift Detector for medical and space applications
… was developed and tested. In addition, different silicon diode detectors were tested as real-time detectors in order to provide a real-time evaluation of the spectrum during diagnostic procedures. This project contributes to the field by presenting an improved simulation of a realistic X-ray beam …
-
Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy
… dosimetry tool that uses a helical array of silicon diode detectors to measure dose in a cylindrical plane. 3DVH is an associated software that can use ArcCHECK diode measurements along with treatment planning system (TPS) data to guide a full 3D dose reconstruction. The ArcCHECK phantom, …
-
Evaluation of Twenty Bermudagrass Cultivars for Their Drought Resistance
… and incoming solar radiation were measured by silicon diode type sensors at the surface of the canopy. The visual parameters: TQ, LF and LC were strongly positively correlated in all experiments during drydown and recovery cycles. Drought resistance as measured by LC varied greatly among the …
-
INVESTIGATION OF X-PINCH PLASMA DYNAMICS USING A PS TIME-RESOLVED X-RAY STREAK CAMERA
… camera, a slit-step wedge camera, an array of silicon diodes, and photoconductive detectors, were used to investigate micropinches. Reproducibility studies were conducted on the Hybrid X-pinch configuration to determine the number of micropinches formed along with their timing as a function of …
-
A Novel Algorithm for the Reconstruction of an Entrance Beam Fluence from Treatment Exit Patient Portal Dosimetry Images
… (TLD), typically CaF or LiF; Metal Oxide Silicon Field Effect Transistor (MOSFET) dosimeters, using threshold voltage shift; Optically Stimulated Luminescent Dosimeters (OSLD), composed of Carbon doped Aluminum Dioxide crystals; RadioChromic film, using leuko-dye polymers; Silicon Diode …
-
Image quality, dose, and quality control in screen-film and full-field digital mammography
… for detection of low-contrast lesions using a silicon diode array FFDM system under the conditions of matched mean glandular dose for a given breast thickness across the full range of compressed breast thicknesses. The FFDM results are then compared to SFM at each breast thickness. The results …
-
Observations of planetary nebulae with multi-element image sensors
Two silicon diode arrays have been used to obtain spectra of the planetary nebula NGC 7027. Relative line intensities (I(H)=100) are determined in the spectral region 5000-9900A. The resolution, good quantum efficiency, and the wide dynamic range available with these detectors permit: i) the …
-
Advanced dual-sided microstructured semiconductor neutron detectors and instrumentation
… neutron conversion material etched deep into silicon pvn-junction diodes. Neutrons react in the conversion material, which produces energetic charged-particle reaction products that are measured in the adjacent silicon microfeatures. Single-sided MSNDs have been produced with an intrinsic …
-
Passive Full-Wave MOSFET Rectifiers for Electromagnetic Harvesting
… studied four different full-wave rectifiers; a silicon diode bridge rectifier, a Schottky diode bridge rectifier, a passive MOSFET rectifier, an an active MOSFET rectifier. Out of simulation results, we found the voltage and power efficiency of each rectifier. We found that MOSFET-type …
-
Polysiloxane based neutron detectors
… to optimize the readout with an avalanche photodiode. This would allow overcoming some issues connected with the use of photomultiplier tubes, in more compact and rugged systems. Finally some preliminary results about the HYDE experiment are presented. This project aims at the development of a …
-
Computational development of the Planar Miniaturized Fast Neutron Detector
… number of stacked, electrically isolated thin-silicon diode detectors. Ideally, incoming neutrons impinge upon the plastic, produce recoil ions, and those recoil ions deposit energy in one or more of the diode detectors placed behind the plastic. The spectrometer is capable of reconstructing …
-
Cryogenic Silicon Microstrip detector modules for LHC
… will cause a serious deterioration of the silicon tracker performance. The state-of-art silicon microstrip detectors can tolerate a fluence of about 3·1014 cm-2 of hadrons or charged leptons. This is insufficient for long-term operation in the central parts of the LHC trackers, in …
-
Détecteurs TéraHertz haute performance pour l’imagerie passive
… de l’azoteliquide.Les bolomètres utilisent une diode latérale PiN avec un film mince de silicium en tant que thermomètre. Ses performances thermométriques sont déterminées par son Coefficient Thermique de Courant (TCC), calculé à partir de simulations numériques en fonction de la température, du …
-
An advanced microstructured semiconductor radiation detector for neutron imaging and oil well logging
… trenches between the top and bottom surface of a silicon diode. This produces a more complex electric field distribution and depletion characteristics in the diode and creates an indirect path for signal carrier transport between device electrodes. Geant4 was extensively utilized for radiation …