Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Simulations GEANT4"”.

  1. System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification

    … designed and characterized through Monte Carlo simulations (Geant4--MEGAlib) and experimental campaigns. A custom list-mode ML-EM reconstruction pipeline, integrating sensitivity and motion corrections, was implemented for online analysis, explicitly accounting for the translation and rotation …

    lmu-germany Repository record for System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification (opens in a new tab)

  2. Characterization of single-sided cadmium zinc telluride strip detectors for high energy astrophysics applications

    … strip detector. We also report on Monte Carlo simulations (GEANT4 v7.1) to investigate the effect of multi-hits on detector performance for both spectroscopy and imaging. We compare simulation results with data obtained from laboratory measurements and discuss the implications for future strip …

    unh-thes Repository record for Characterization of single-sided cadmium zinc telluride strip detectors for high energy astrophysics applications (opens in a new tab)

  3. Incorporating microdosimetry into radiation therapy treatment planning with multi-scale Monte Carlo simulations

    … method for performing multi-scale Monte Carlo simulations to obtain microdosimetric information for patient specific treatments. This is done by using a track structure Monte Carlo simulation in the regions of interest for scoring and a condensed history algorithm for the rest of the geometry. …

    ubc Repository record for Incorporating microdosimetry into radiation therapy treatment planning with multi-scale Monte Carlo simulations (opens in a new tab) Download PDF for Incorporating microdosimetry into radiation therapy treatment planning with multi-scale Monte Carlo simulations (opens in a new tab)

  4. Geant4 modelling of DNA strand breaks from diffusing alpha-emitters radiation therapy

    … into tumours. Monte Carlo track structure simulations (Geant4 and Geant4-DNA) were used to simulate the DNA damage due to DaRT.<br/><br/>Mono-energetic simulations of the α-particles in DaRT showed the high LET of the α-particles increases DNA damage complexity compared to low LET …

    bristol Repository record for Geant4 modelling of DNA strand breaks from diffusing alpha-emitters radiation therapy (opens in a new tab) Download PDF for Geant4 modelling of DNA strand breaks from diffusing alpha-emitters radiation therapy (opens in a new tab)

  5. Passive shielding of space radiation for human exploration missions - Simulations and Radiation Tests

    … were calculated with the aid of 1D Monte Carlo simulations, also followed by an evaluation of their structural and thermal proprieties, cost, availability and compatibility with the space environment. Simulations, in particular, were performed both to support the material selection process both …

    poli-torino Repository record for Passive shielding of space radiation for human exploration missions - Simulations and Radiation Tests (opens in a new tab)

  6. Έλεγχος ποιότητας δεδομένων υψηλής ανάλυσης των μετρητών νετρονίων και ανάπτυξη τεχνικών προσομοίωσης

    … Athens' station with reliable results. Finally, simulations with Geant4 have been developed, for the study of the Neutron Monitors and of the particle cascades in the Earth's atmosphere with very impressive results, which allow future applications in Space weather.

    greece Repository record for Έλεγχος ποιότητας δεδομένων υψηλής ανάλυσης των μετρητών νετρονίων και ανάπτυξη τεχνικών προσομοίωσης (opens in a new tab)

  7. Studio dello scattering 18O + 48Ti a 275 MeV, simulazioni Monte Carlo e caratterizzazione sperimentale del rivelatore di piano focale di MAGNEX per il progetto NUMEN

    Negli ultimi anni il doppio decadimento beta senza neutrini (0νββ) ha attirato molto interesse da parte della comunità scientifica dal momento che la sua osservazione rappresenterebbe la prima evidenza sperimentale di fisica oltre il Modello Standard. Il progetto NUMEN ha proposto ai Laboratori …

    catania Repository record for Studio dello scattering 18O + 48Ti a 275 MeV, simulazioni Monte Carlo e caratterizzazione sperimentale del rivelatore di piano focale di MAGNEX per il progetto NUMEN (opens in a new tab)

  8. X-ray detector design for a keV scale sterile neutrino search

    Neutrino flavor oscillation experiments provide evidence of physics beyond the Standard Model. Specifically the potential for an additional neutrino which interacts solely with the currently ob- served, active neutrinos. This proposed, sterile, neutrino interacts via a weak coupling and is involved …

    houston Repository record for X-ray detector design for a keV scale sterile neutrino search (opens in a new tab)

  9. Transient Simulations of the SLOWPOKE-2 Reactor Using the G4-STORK Code

    … of the SLOWPOKE-2 reactor using Monte-Carlo simulations with the G4-STORK code. G4-STORK is a 3-dimensional Monte-Carlo code derived from the GEANT4 physics simulation toolkit. Methods were developed for the proper treatment of delayed neutrons and a lumped capacitance model was used to track …

    mcmaster Repository record for Transient Simulations of the SLOWPOKE-2 Reactor Using the G4-STORK Code (opens in a new tab)