Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 37 for “"Single coil"”.

  1. EnergyPlus Simulation of Single-Coil Twin-Fan Air Conditioning System

    … energy performance of the newly-developed Single-Coil Twin-Fan (SCTF) air conditioning system. The objectives of this project were to develop a customized module of the energy efficient SCTF system, validate the model using industry-accepted simulation verification methods, and implement …

    nus Repository record for EnergyPlus Simulation of Single-Coil Twin-Fan Air Conditioning System (opens in a new tab) Download file for EnergyPlus Simulation of Single-Coil Twin-Fan Air Conditioning System (opens in a new tab)

  2. Directly driven, low-speed permanent-magnet generators for wind power applications

    … second machine has a three-phase, unconventional single-coil winding consisting of coils which are placed in slots around every second tooth. The electromagnetic optimisation of the machine is done by the finite element method and by a genetic algorithm combined with the finite element method. The …

    aalto Repository record for Directly driven, low-speed permanent-magnet generators for wind power applications (opens in a new tab)

  3. Power Repeaters for Inductive Power Transfer

    … relay power. Power repeaters can be in form of a single coil or multiple coils in matrix forms that are known as matrix power repeaters. Although being effective, the operating mechanism and the actual effect of even a single coil passive power repeater on an IPT system is not clear, so the design …

    auckland-ms Repository record for Power Repeaters for Inductive Power Transfer (opens in a new tab)

  4. Simulace tepelně-aktivovaných základových konstrukcí budov

    … piloty na dvou způsobech instalace potrubí – Single coil, kde je vratné potrubí vedeno středem piloty a Duplex coil s vratem ve tvaru spirály.

    brno-tech Repository record for Simulace tepelně-aktivovaných základových konstrukcí budov (opens in a new tab)

  5. Study of phase information in MRI with applications to fast imaging and inversion recovery imaging

    … demonstrated so far only in 2D and only with a single coil. This thesis presents new developments based on the principle of SPEED: First, SPEED is extended from 2D to 3D to reduce scan time with more flexibility and efficiency; Second, SPEED is combined with Half-Fourier imaging to accelerate …

    ubc Repository record for Study of phase information in MRI with applications to fast imaging and inversion recovery imaging (opens in a new tab) Download PDF for Study of phase information in MRI with applications to fast imaging and inversion recovery imaging (opens in a new tab)

  6. Construction of nuclear magnetic resonance spectroscope and its calibration

    … In recent years a low cost instrument of the single coil type has been constructed by the Aero Medical Laboratory which is alright for demonstration purposes but cannot be used for research because of low resolution. The idea of the present project was to see whether a similar instrument of …

    u-pacific Repository record for Construction of nuclear magnetic resonance spectroscope and its calibration (opens in a new tab)

  7. Algorithmic control of multi-locus transcranial magnetic stimulation: Motor mapping and pulse delivery

    … decades ago: an operator manually positions a single coil over the scalp and delivers stimulation pulses to a selected brain region. This workflow is slow, depends on operator skill, and cannot easily target activation to spatially distributed brain networks, which often underlie brain …

    aalto Repository record for Algorithmic control of multi-locus transcranial magnetic stimulation: Motor mapping and pulse delivery (opens in a new tab)

  8. Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency

    … of the newly developed compartmented cooling coil of the Single Coil Twin Fan air-conditioning and air distribution system. A fundamental mathematical model has been formulated and validated based on a comprehensive experimental methodology. Efforts have been taken to derive unique boundary …

    nus Repository record for Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency (opens in a new tab) Download file for Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency (opens in a new tab)

  9. Deep Learning Reconstruction for Dynamic Fetal Cardiac MRI

    … learning and traditional k-t SENSE.<br/>Under a single-coil assumption, U-Net-based models were systematically evaluated for their ability to reconstruct training stage data. A network that processes inputs in the temporal frequency domain with the time-averaged signals removed and re-added at …

    kings Repository record for Deep Learning Reconstruction for Dynamic Fetal Cardiac MRI (opens in a new tab) Embargoed until 2027-01-01

  10. SPACE-DEPLOYED, THIN-WALLED ENCLOSURE FOR A CRYOGENICALLY-COOLED HIGH TEMPERATURE SUPERCONDUCTING COIL

    … fields generated by large superconducting coils has multiple applications in space, including actuation of spacecraft or spacecraft components, wireless power transfer, and shielding of spacecraft from radiation and high energy particles. These applications require coils with major …

    maryland Repository record for SPACE-DEPLOYED, THIN-WALLED ENCLOSURE FOR A CRYOGENICALLY-COOLED HIGH TEMPERATURE SUPERCONDUCTING COIL (opens in a new tab)

  11. Cost Minimization for Hot Gas Defrost System

    Frost accumulation on evaporator coils has been a serious problem that decreases the efficiency of refrigeration systems. Many defrost methods have been used and hot gas defrost is the most common for industrial refrigeration applications. However, it is not a simple task to run an efficient hot …

    calpoly Repository record for Cost Minimization for Hot Gas Defrost System (opens in a new tab)

  12. Approximate message passing for compressed sensing magnetic resonance imaging

    … MRI data. We present three versions of VDAMP: single-coil VDAMP, where receiver coil sensitivities are ignored, Parallel-VDAMP (P-VDAMP), which includes coil sensitivities, and Denoising-P-VDAMP (D-P-VDAMP), which incorporates the statistical modelling capabilities of neural networks. Central …

    oxford Repository record for Approximate message passing for compressed sensing magnetic resonance imaging (opens in a new tab)

  13. Magneto inductive communication system for underwater wireless sensor networks

    … MI sensor node combat the directionality of the single coil MI communication by utilizing 3D coil to both transmit and receive. The presented MI sensor node is tested in air and underwater to show robustness and reliability. The sensor node is designed after thorough analysis and evaluation of …

    must-thes Repository record for Magneto inductive communication system for underwater wireless sensor networks (opens in a new tab)

  14. A multi-coil magnetostrictive actuator: design, analysis, and experiment

    … actuator that employs individually controlled coils distributed axially along the magnetostrictive rod. As a quantitative goal, the objective is to show that the multi-coil actuator can operate effectively at frequencies as high as 10,000 Hz with 900 N force and 50 microns of displacement. …

    gatech Repository record for A multi-coil magnetostrictive actuator: design, analysis, and experiment (opens in a new tab)

  15. [Carbon-13] solid-state NMR study of ethylene oxidation over supported silver catalysts

    … (CP/MAS), CP/MAS with dipolar dephasing, and single-pulse experiments have been applied to identify carbon containing species that are formed on the surface of catalyst at various temperatures. Ethylene, acetic acid, carbon dioxide, ethane and an alkoxy species have been identified. Under the …

    iastate Repository record for [Carbon-13] solid-state NMR study of ethylene oxidation over supported silver catalysts (opens in a new tab)

  16. AN EXPERIMENTAL INVESTIGATION ON THE EFFECT OF DUAL COIL IGNITION DISCHARGES ON DILUTE COMBUSTION IN A SPARK IGNITION ENGINE

    … on performance of the modern Transistorized Coil Ignition (TCI) system and hence presents a limitation on improving combustion rates. Additionally, dilute combustion has a detrimental effect on combustion stability, wherein a larger variation in engine cycle work is observed from cycle to …

    mtu Repository record for AN EXPERIMENTAL INVESTIGATION ON THE EFFECT OF DUAL COIL IGNITION DISCHARGES ON DILUTE COMBUSTION IN A SPARK IGNITION ENGINE (opens in a new tab)

  17. A 16-Channel Receive Array Insert for Magnetic Resonance Imaging of the Breast at 7T

    … the availability of commercial radiofrequency coils for 7T. The primary objective of this work is to enable the study of breast cancer at 7T with the development of a 16-channel receive array coil. The use of array coils to receive is standard in clinical MRI, as it provides higher SNR over a …

    tamu Repository record for A 16-Channel Receive Array Insert for Magnetic Resonance Imaging of the Breast at 7T (opens in a new tab)

  18. Cellular level studies and coil system design for transcranial magnetic stimulation

    … disease and PTSD. It uses pulsed currents in the coils to generate time varying magnetic field which induce eddy currents in the conductive tissues of human brain. Recently, there are several research publications in the field of TMS, specifically on coil designs, clinical trials and some in-vivo …

    iastate Repository record for Cellular level studies and coil system design for transcranial magnetic stimulation (opens in a new tab)

  19. A 2-D micro-magnetic neuro-stimulation platform

    … involves the design, fabrication and testing of single coil geometries and a two dimensional array of micro-coils for establishing spatio-temporal magnetic flux profiles. The proposed device can induce a localised electric field in the vicinity of the coils that can instigate the stimulation of …

    soton Download PDF for A 2-D micro-magnetic neuro-stimulation platform (opens in a new tab)

Page 1 of 2