Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 265 for “"Single-photon emission computed tomography"”

  1. A MATHEMATICAL MODEL OF SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY

    Single-photon emission computed tomography (SPECT) is a nuclear-medicine imaging technique that has been shown to provide clinically useful images of radionuclide distributions within the body. The problem of quantitative determination of tomographic activity images from a projection data set leads …

    arizona-thes Repository record for A MATHEMATICAL MODEL OF SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY (opens in a new tab)

  2. Single photon emission computed tomography: performance assessment, development and clinical applications

    This is a general investigation of the SPECT imaging process. The primary aim is to determine the manner in which the SPECT studies should be performed in order to maximise the relevant clinical information given the characteristics and limitations of the particular gamma camera imaging system …

    glasgow Repository record for Single photon emission computed tomography: performance assessment, development and clinical applications (opens in a new tab)

  3. Attenuation, noise, and image quality in single-photon emission computed tomography

    In single-photon emission computed tomography (SPECT), the goal is to estimate the biodistribution of radioactive pharmaceuticals that have been administered to a patient. Various degrading physical effects contribute to inaccuracies in the estimation process. In this dissertation, we examine the …

    arizona-thes Repository record for Attenuation, noise, and image quality in single-photon emission computed tomography (opens in a new tab)

  4. On-board Single Photon Emission Computed Tomography (SPECT) for Biological Target Localization

    … high tumor burden, or increased proliferation. Single photon emission computed tomography (SPECT) is sensitive to physiology. We propose on-board SPECT for biological target localization.</p><p>Localization performance was studied in computer-simulated and scanner-acquired parallel-hole SPECT …

    duke Repository record for On-board Single Photon Emission Computed Tomography (SPECT) for Biological Target Localization (opens in a new tab)

  5. Single-Photon Emission Computed Tomography (SPECT) Imaging of Alpha-emitting Radiopharmaceutical Therapy

    … introduced in RPT, and most of them also emit photons that allow image-based dose assessment using single-photon emission computed tomography (SPECT). Among these isotopes, Pb-212 has gained significant interest due to its promising clinical development. However, direct imaging of Pb-212 is …

    arizona-thes Repository record for Single-Photon Emission Computed Tomography (SPECT) Imaging of Alpha-emitting Radiopharmaceutical Therapy (opens in a new tab)

  6. An Investigation of Markov Random Fields for Bayesian Reconstruction of Single Photon Emission Computed Tomography

    <p>This research investigates the use of Markov random fields for Bayesian reconstruction algorithms to be used with high-resolution and high-sensitivity SPECT systems for small animal imaging. It extends previous research on mechanical models for Bayesian image reconstruction by using a …

    utk-theses Repository record for An Investigation of Markov Random Fields for Bayesian Reconstruction of Single Photon Emission Computed Tomography (opens in a new tab)

  7. Read-out electronics for a single photon emission computed tomography (SPECT) small animal imaging system

    … electronics have been designed for a new single photon emission computed tomography (SPECT) system. The SPECT system was incorporated into the existing Oak Ridge National Laboratory's MicroCAT X-ray CT imaging system for the purpose of complete dual-modality small animal imaging. Data …

    ut-knoxville Repository record for Read-out electronics for a single photon emission computed tomography (SPECT) small animal imaging system (opens in a new tab)

  8. A template-based method for semi-quantitative single photon emission computed tomography myocardial perfusion imaging

    This thesis presents the template-based quantitative perfusion SPECT (TQPS) method, which is designed for the semi-quantitative analysis in SPECT myocardial perfusion imaging (MPI). Unlike traditional methods employing normal patient databases as the healthy standard when quantifying myocardial …

    ubc Repository record for A template-based method for semi-quantitative single photon emission computed tomography myocardial perfusion imaging (opens in a new tab)

  9. Voxel based quantitative analysis of distance dependent resolution correction in single photon emission computed tomography.

    … (DDR) correction is commonly applied to single photon emission computed tomography (SPECT) iterative image reconstruction but how much improvement in image quality is gained by the additional computational expense associated with the correction? This work examined the effect of the …

    adelaide Repository record for Voxel based quantitative analysis of distance dependent resolution correction in single photon emission computed tomography. (opens in a new tab)

  10. The use of single photon emission computed tomography in the investigation of parathyroid and thyroid disorders

    … disorders of the parathyroid and thyroid glands. Single photon emission computed tomography (SPECT) can also be carried out. This is a three-dimensional nuclear medicine imaging technique that gives both increased image contrast due to the separation of overlying structures and improved …

    glasgow Repository record for The use of single photon emission computed tomography in the investigation of parathyroid and thyroid disorders (opens in a new tab)

  11. Resolution Study of a γ-Camera System for Single Photon Emission Computed Tomography (SPECT) at Preclinical Level

    Η παρούσα διπλωματική εργασία αποτελεί μια πειραματική μελέτη που εστιάζει στον προσδιορισμό της διακριτικής ικανότητας ενός συστήματος μικρού πεδίου γ-Camera, το οποίο προορίζεται για Μονοφωτονική Τομοσπινθηρογραφία (SPECT) σε προκλινικό επίπεδο. Ο χωρικά ευαίσθητος Φωτοπολλαπλασιαστής (PSPMT) …

    athens Repository record for Resolution Study of a γ-Camera System for Single Photon Emission Computed Tomography (SPECT) at Preclinical Level (opens in a new tab)

  12. Resting-State Cerebral Perfusion Patterns: An Exploratory Factor Analysis of Single-Photon Emission Computed Tomography Clinical Data

    … the literature until 2005. Few studies have used single-photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) to analyze RS. The omission is critical because SPECT RS networks have a different structure and statistical representation than functional magnetic resonance …

    nova2 Repository record for Resting-State Cerebral Perfusion Patterns: An Exploratory Factor Analysis of Single-Photon Emission Computed Tomography Clinical Data (opens in a new tab)

  13. Dysfunctional but viable myocardium - ischemic heart disease assessed by magnetic resonance imaging and single photon emission computed tomography

    … function, perfusion and viability using single photon emission computed tomography (SPECT) and cardiac magnetic resonance (CMR). Polar representation of these parameters was feasible, and the quantitative method agreed with visual assessment. Paper II showed that wall thickening decreases …

    lund Repository record for Dysfunctional but viable myocardium - ischemic heart disease assessed by magnetic resonance imaging and single photon emission computed tomography (opens in a new tab)

  14. The Use of Single Photon Emission Computed Tomography to Indicate Neurotoxicity in Cases of Pesticide and Solvent Exposures

    … chemical exposures on brain processes using Single Photon Emission Computed Tomography (SPECT). A control group carefully screened for good health and minimal chemical exposures was compared to two groups of patients diagnosed with health problems following exposure to pesticides or to …

    unt Repository record for The Use of Single Photon Emission Computed Tomography to Indicate Neurotoxicity in Cases of Pesticide and Solvent Exposures (opens in a new tab)

  15. Development and Evaluation of Quantitative Methods of Analysing Single Photon Emission Computed Tomography Blood Flow Images of the Brain

    … evaluation of quantitative methods of analysing single photon emission computed tomography blood flow images of the brain. This thesis presents the investigations carried out on a particular method of functional human brain mapping (FHBM) analysis (SPM)1 as to its applicability to a routine …

    glasgow Repository record for Development and Evaluation of Quantitative Methods of Analysing Single Photon Emission Computed Tomography Blood Flow Images of the Brain (opens in a new tab)

  16. A Comparative Analysis of Cerebral Blood Flow in Children and Adults with ADHD Using Single Photon Emission Computed Tomography

    … levels in children and adults with ADHD using single-photon emission computed tomography (SPECT). The present study measured rCBF across both hemispheres and multiple brain regions, including the cerebellum, frontal lobe, occipital lobe, parietal lobe, temporal lobe, and vermis, to identify …

    nova2 Repository record for A Comparative Analysis of Cerebral Blood Flow in Children and Adults with ADHD Using Single Photon Emission Computed Tomography (opens in a new tab)

Page 1 of 14