Development of an Autonomous Single-Point Calibration for a Constant Voltage Hot-Wire Anemometer
… Boundary Layer Data System (BLDS). A hot-wire calibration apparatus has been developed that is capable of operation inside a vacuum chamber and flow speeds up to 50 m/s. Hot-wires operated with a constant-voltage anemometer (CVA) were calibrated at absolute static pressures down to 26 kPa. A …
-
Point of care intravenous anaesthetic measurement in anaesthesia and critical care
… of determining propofol concentrations at the point of care may lead to an improved accuracy of drug delivery. Validation work on a novel analyser measuring propofol concentration in near real time demonstrate a high level of precision for samples in the clinical range. Further work in the …
-
Characterisation of a Cavity Ring-Down Spectrometer for measuring CO2, CH4, delta13CO2, and delta13CH4 in ambient air
… CH4 concentrations was observed. Nevertheless, a single-point calibration yields CO2 and CH4 concentrations which are compatible to other routine instruments (i.e. Fourier Transform InfraRed spectrometer (FTIR) and gas chromatograph) in Heidelberg within the World Meteorological Organization …
-
Quantification of Fourth Generation Kapton Heat Flux Gauge Calibration Performance
… Gas Turbine Laboratory are driven by two main calibrations, the sensors temperature as a function of resistance and the material properties of Kapton. The material properties separate into those that govern the steady-state response of the gauge and those that influence the transient response. …
-
Heart health monitoring wearable device
… accuracy, subject specific and frequent calibration is required. A novel calibration procedure was developed that can achieve accurate BP measurements with longer calibration intervals. The performance of the proposed procedure was tested on 10 subjects in a preliminary study, and on 33 …
-
Development of selected sulphur compounds and oxygenated volatile organic compounds reference gas mixtures for air quality monitoring
… oxygenated volatile organic compounds. A multi-point calibration method was used to analyse sulphur dioxide and hydrogen sulphide on the NDUV analyser, and the single-point calibration method was used for analysis on the gas chromatography and UV fluorescence where a sample mixture is analysed …
-
Self-powered biosensors for water quality monitoring: sensor design and signal treatment : (Alternative Format Thesis)
… to detect pesticides in water. The detection of single toxic events of 0.1 µg L-1 of the herbicides Diuron and glyphosate was statistically significant (α = 0.01) based on changes in accumulated charge and accumulated variance, in five days before and after the toxic event. The correlation of the …
-
Graphene-Based Platforms for In Vitro Diagnosis and Brain-on-a-Chip Monitoring of Neurodegenerative Disease Progression
… multiple remote gates operated through a single EGFET device, reducing fabrication demands and enhancing reproducibility. Process optimisations, including improved graphene transfer techniques, reduction of contact resistance, careful substrate selection, and the use of enhanced …
-
Remote, Non-contact Gaze Estimation with Minimal Subject Cooperation
… presents a novel system that estimates the point-of-gaze (where a person is looking at) remotely while allowing for free head movements and minimizing personal calibration requirements. The point-of-gaze is estimated from the pupil and corneal reflections (virtual images of infrared light …
-
The use of charged aerosol detection for the analysis of excipients and active pharmaceutical ingredients
… narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an …
-
Improving efficiency and performance of liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) as used in therapeutic drug monitoring
… or reanalysis. Chapter 4 explores alternative calibration methods designed to enhance efficiency and reduce laboratory costs. It compares single-point and multi-point calibration approaches for quantifying 5-fluorouracil (5FU). The findings suggest that the choice of calibration method not only …