Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 28 for “"Sinograms"”
-
Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification
… systems have the unique attribute of using sinograms as a machine input and a machine output. These sinograms have well understood properties that may allow for operational changes that simplify and/or improve radiation treatment.</p> <p>In the first part of this work, the detector array …
-
Software tools for 3-D PET imaging : design and development
… attenuation, and detector efficiency in PET sinograms. Normally, scatter and randoms correction techniques do not improve image quality much for two-dimensional images. However, since nearly 50% of three-dimensional PET sinogram data is noise from these sources, data correction to compensate …
-
Initial design and simulation of a portable breast microwave detection device
… radar model was used to simulate time-domain sinograms of dual rod models. The rod models consisted of two point scatterers with assigned reflectivities of 100% & m% or m% & m%, where m was varied as: 10%, 30%, 50%, 70%, and 90%. The simulated sinograms were used to train a convolutional …
-
Machine Learning Methods of Material Decomposition in Special Computed Tomography Using Photon Counting Detectors
… networks decomposed each ray in the measured sinograms into material separated sinograms and reconstructed into basis material images. The capabilities of the machine learning algorithm were evaluated experimentally with a rod phantom with calculated biases of 0.3%to 7.6% compared to biases of …
-
Readout of polymer gel dosimeters using a prototype fan-beam optical computed tomography scanner
… reductions in readout noise were not lost when sinograms with many projections were encapsulated into sinograms of fewer projection angles. Detector element binning (sinogram space) and pixel binning (image space) also provided substantial reductions in readout noise. None of these elements of …
-
Polarimetric Tomography for Anisotropic Samples
… the 3D index ellipsoid distribution from sinograms composed solely of cross-sectional ellipses orthogonal to each projection direction. Using this approach, both reconstructions from optical path lengths, which serve as an intermediate step, and reconstructions based directly on …
-
System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner
… curve. Fits were used on the motion-encoded sinograms to determine both of these curves and, consequently, the amount and direction of motion that occurred. Each projection was individually adjusted to compensate for this motion by widening or narrowing the projection based on the ratio of …
-
Modeling and Development of Iterative Reconstruction Algorithms in Emerging X-ray Imaging Technologies
… statistical properties of the object property sinograms, including correlations between them, into the formulation of an advanced multi-channel (MC) image reconstruction algorithm, which reconstructs three object properties simultaneously. We developed an advanced algorithm based on the …
-
Motion Correction and Pharmacokinetic Analysis in Dynamic Positron Emission Tomography
… of using time-weighted average of attenuation sinograms to reconstruct dynamic frames. Extensive validation studies show that GIIMC algorithm outperforms conventional techniques producing images with superior quality and quantitative accuracy. Parametric Myocardial Perfusion PET Imaging: We …
-
Deep Learning in Positron Emission Tomography Image Reconstruction
… is described that works directly from raw sinograms and attenuation maps to create multi-slice full-size image volumes with a purposely designed Radon inversion layer. DirectPET generates images that are quantitatively and qualitatively similar to the conventional ordered subset expectation …
-
Scatter Estimation and Correction for Experimental and Simulated Data in Multi-Slice Computed Tomography Using Machine Learning and Minimum Least Squares Methods
… data from 24 mm collimation data. Pairs of sinograms, both experimental data and simulated data, from 3 mm and 24 mm collimation data are used to derive methods for this scatter correction. One method uses a linear least-squares approach to derive a linear estimator. A second method uses a …
-
Development of a Novel Technique for Predicting Tumor Response in Adaptive Radiation Therapy
… errors and different attenuations from the sinograms that were used to develop the model. The model proved to be robust and could predict the correct “error-free” values for a projection in which the opening time of a single MLC leaf had been decreased by 10%. The model also was able to …
-
Model-based randoms correction for 3D positron emission tomography
… with the measured, except that the calculated sinograms were smooth. Images corrected with both methods showed no significant differences due to biases. However, in the situations tested, no significant difference in the noise level o f the reconstructed images was detected due to the low …
-
A Study of the Prevalence of Patient Body Motion and Its Subsequent Correction by Projection Consistency Conditions
… and blood regions. Noise was added to sinograms using the analytical simulator ASIM. In the patient cohort mild motion 0.5 ± 0.1 cm occurred in 24%, and severe motion 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected …
-
Enhanced reconstruction and material recognition in X-ray CT for security applications
… We decompose the measurements into basis sinograms and generate basis coefficient images to estimate material properties. We integrate metal artifact reduction techniques commonly found in single energy CT with dual-basis image reconstructions and propose novel reconstruction algorithms to …
-
System Optimization and Image Reconstruction for Spectral Computed Tomography
… it possible to compute accurate basis-material sinograms in clinically reasonable amounts of time. Lastly, spectral CT involves reconstructing multiple data channels, which could correspond to different energies or basis materials. Since these channels all represent the same basic anatomy, there …
-
Advances in dual-energy computed tomography imaging of radiological properties
… clinically achievable noise level added to the sinograms, iFBP-AC greatly outperforms iFBP in prediction of photon linear attenuation at low energy, i.e., 28 keV. The estimated mean errors of iFBP and iFBP-AC for cortical bone are 1% and 0.7%, respectively; the standard deviations are 0.6% and …
-
The Foundation of Modern Korean Digraphia: Metanarration, Nationalism and Politics
… began the implementation of the plan to abolish sinograms, and then returned to including them to the South Korean education system in 1971-1972. Limited use of sinograms in selected print media and official documents continued. The doctoral dissertation ends with the seventh chapter, which …
-
The Alvarez-Macovski Model and Quantitative X-ray Computed Tomography
… We can then use the variance and mean sinograms as the two inputs in a usual DECT algorithm and generate artefact free, quantitative XCT tomograms without simplifying the attenuation model itself. Furthermore, the variance and the mean data can also be used to generate a beam-hardening …
-
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
… are evaluated using synthetic DECT transmission sinograms of virtual cylindrical phantoms and virtual patients, which consist of reference human tissues with known densities and compositions. The JSIR-BVM method is then experimentally commissioned using the DECT measurement data acquired on a …
Page 1 of 2