Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Slab Column Connection"”.

  1. Further Investigation of a New RC Slab-Column Connection for Improved Seismic Performance of Multi-Story Buildings

    Concrete Filled Steel Tube (CFST) columns have several advantages over reinforced concrete columns in that: (1) the steel tube provides confinement of the concrete and reduces damage to the concrete core, (2) they possess very high shear capacities, (3) the steel tube is placed at the optimum …

    washington Repository record for Further Investigation of a New RC Slab-Column Connection for Improved Seismic Performance of Multi-Story Buildings (opens in a new tab)

  2. Non-destructive evaluation of gravity load carrying capacity and lateral load damage of reinforced concrete slab-column connections

    … to quantify the load carrying capacity of a slab-column connection as a function of the structural damage. To fulfill this objective, guidelines for damage assessment of reinforced concrete flat-plate buildings were developed. The intent of the guidelines was to assist engineers assess …

    texas Repository record for Non-destructive evaluation of gravity load carrying capacity and lateral load damage of reinforced concrete slab-column connections (opens in a new tab)

  3. Two-way shear strength of reinforced concrete slab-column connections : influence of testing conditions in isolated specimens

    … punching shear strength, of reinforced concrete slabs, code provisions fitted from experimental data are typically employed. The experimental data forming the bases of these provisions have generally consisted of isolated slab-column connection tests that seek to represent the negative moment …

    texas Repository record for Two-way shear strength of reinforced concrete slab-column connections : influence of testing conditions in isolated specimens (opens in a new tab)

  4. Punching Shear Retrofit Method Using Shear Bolts for Reinforced Concrete Slabs under Seismic Loading

    Reinforced concrete slab-column structures are widely used because of their practicality. However, this type of structures can be subject to punching-shear failure in the slab-column connections. Without shear reinforcement, the slab-column connection can undergo brittle punching failure, …

    waterloo Repository record for Punching Shear Retrofit Method Using Shear Bolts for Reinforced Concrete Slabs under Seismic Loading (opens in a new tab)

  5. Punching failure and compressive membrane action in reinforced concrete slabs

    … membrane action in reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to concentrated loadings.The results of an extensive series of tests on one quarter scale models of the interior slab—column connection in …

    qu-belfast Repository record for Punching failure and compressive membrane action in reinforced concrete slabs (opens in a new tab) Download PDF for Punching failure and compressive membrane action in reinforced concrete slabs (opens in a new tab)

  6. Seismic response of slab-column connections with shear capitals

    The punching shear strength of the slab usually governs the design of slab-column connections in regions of high seismicity. One method of increasing the shear capacity of the connection region is to increase the thickness of the slab using shear capitals. A shear capital is a thickened portion of …

    rice Repository record for Seismic response of slab-column connections with shear capitals (opens in a new tab)

  7. Seismic resistance of slab-column connections in non-ductile flat-plate buildings

    … flat-plate buildings, four reinforced concrete slab-column connection subassemblies designed for gravity load only were built at half-scale of prototype structure, and tested at Ryon laboratory of the Rice University. Each specimen had two exterior and one interior connections. The variables …

    rice Repository record for Seismic resistance of slab-column connections in non-ductile flat-plate buildings (opens in a new tab)

  8. Investigation of the effects of dynamic loads on reinforced concrete flat-plate buildings under collapse scenarios

    … collapse, failure of the initiating member (i.e. column loss) can cause a dynamic load redistribution in the surrounding members. The ability of the structure to withstand these dynamically redistributed loads will determine if the building is susceptible to collapse. If the surrounding members …

    missouri Repository record for Investigation of the effects of dynamic loads on reinforced concrete flat-plate buildings under collapse scenarios (opens in a new tab)

  9. Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear

    … punching behaviour of reinforced concrete flat slabs supported on columns with headed stud/bolt shear reinforcement, there are still many parameters which have not been adequately studied in the laboratory due to cost or time constraints. As a result much of the current code provisions for …

    waterloo Repository record for Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear (opens in a new tab)

  10. Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings

    … seismic loads. The deformation capacity of a slab-column connection is a function of vertical shear transferred from slab to column. The effects of vertical loading become even more exaggerated when the flat-plate structure is located near a fault. Near-source seismic events can cause large …

    unlv Repository record for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab) Download PDF for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab)

  11. Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections

    … that often includes reinforced concrete flat slabs. A major challenge with the design of this system is ensuring adequate strength and deformation capacities of the flat slab-column connections, especially when the structure is prone to strong seismic excitations. When a flat slab-column …

    ubc Repository record for Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections (opens in a new tab) Download PDF for Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections (opens in a new tab)

  12. Evaluation of tensile and compressive membrane action in isolated slab column specimen

    … progressive collapse in which the failure of one slab-column connection can propagate to other connections and cause a full collapse of the building. The most common mechanism of failure in flat-plates is known as punching shear, when inclined shear cracks propagate through the depth of the slab …

    missouri Repository record for Evaluation of tensile and compressive membrane action in isolated slab column specimen (opens in a new tab)

  13. An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs

    … the punching shear behaviour of ground-suspended slabs with internal columns. The main objectives of this research were to develop a constitutive model for steel fibre-reinforcement (SFRC), to study experimentally the punching shear behaviour of SFRC with no longitudinal reinforcement and to …

    liverpool-jm Repository record for An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs (opens in a new tab) Download PDF for An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs (opens in a new tab)

  14. A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings

    Slab-column systems are commonly used as the gravity system of reinforced concrete buildings in high seismic regions. These systems are economical and typically constructed using stud rails at the reinforcement for the slab-column connection. However, prior work indicates that these connections are …

    washington Repository record for A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings (opens in a new tab)

  15. Toward practical modeling of reinforced concrete flat plate structures

    … was found to provide good response estimates for slab-column connection specimens under concentric shear loading and effectively captured the effects of different parameters on punching performance: reinforcement ratio, column size, and slab thickness. The validated solid modeling procedure was …

    texas Repository record for Toward practical modeling of reinforced concrete flat plate structures (opens in a new tab)

  16. Shell-Based Finite Element Analysis of Reinforced Concrete Slabs Subjected to Non-uniform Stress Distribution at Column Connection Regions

    … the punching shear resisting performance of RC slab-column connections under variable connection shear stress conditions. Variation of connection stress conditions stems from columns with different cross-section aspect ratios, different distributions of gravity loading conditions, slabs …

    waterloo Repository record for Shell-Based Finite Element Analysis of Reinforced Concrete Slabs Subjected to Non-uniform Stress Distribution at Column Connection Regions (opens in a new tab)

  17. Infill panel system for seismic strengthening of flat-plate buildings

    … typically the result of punching failure at the slab-column connection. Because of this, performance-based retrofit procedures are needed to upgrade these non-ductile buildings. This investigation evaluated the use of lightweight pumice stone concrete (LWPSC) infill panels as a retrofit …

    rice Repository record for Infill panel system for seismic strengthening of flat-plate buildings (opens in a new tab)

  18. Numerical and Experimental Investigation of Punching Shear of Slab-Column Connections Retrofitted with Ultra High Performance Fibre Reinforced Concrete (UHPFRC)

    … occur in reinforced concrete buildings at the slab-column connection area. Many times, such a failure mode can initiate a potential progressive collapse of the building. An in-depth investigation was performed to examine possible structural failures of flat slab construction, as well as …

    queens Repository record for Numerical and Experimental Investigation of Punching Shear of Slab-Column Connections Retrofitted with Ultra High Performance Fibre Reinforced Concrete (UHPFRC) (opens in a new tab)

  19. Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections

    … provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …

    waterloo Repository record for Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections (opens in a new tab)

Page 1 of 2