Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Slab Specimen"”
-
Nondestructive Evaluation Of Corrosion Damage In Reinforced Concrete Aged Slab Specimen
… is significant. In this study, a bridge deck specimen was subjected to an artificial environment to accelerate the corrosion process. Prior to this step, visual inspection, Ground Penetrating Radar (GPR), Infrared Thermography (IR), Impact Icho (IE), and Half- Cell Potential (HCP) were …
-
Punching failure and compressive membrane action in reinforced concrete slabs
… membrane action in reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to concentrated loadings.The results of an extensive series of tests on one quarter scale models of the interior slab—column connection in …
-
Two-way shear strength of reinforced concrete slab-column connections : influence of testing conditions in isolated specimens
… punching shear strength, of reinforced concrete slabs, code provisions fitted from experimental data are typically employed. The experimental data forming the bases of these provisions have generally consisted of isolated slab-column connection tests that seek to represent the negative moment …
-
REDUCTION OF TRANSVERSE CRACKING IN STRUCTURAL SLAB BRIDGE DECKS USING ALTERNATIVE MATERIALS
… the bridge. The CSS (Continuous Span Structural Slab) bridges, without stringers and are the most commonly used bridges in counties over the streams. Several CSS bridges in Ohio were surveyed to inspect crack widths on the bridge decks; and it was found that the crack widths over the negative …
-
Punching shear in edge and corner column slab connections of flat plate structures.
… behavior and strength of edge and corner column slab connections of flat plate structures subjected to shear force only, moment only as well as combined shear force and moment were investigated. A two bay by two bay flat plate structure (nine columns) and eight isolated edge column slab …
-
Application of piezoelectric materials to monitor modulus and strength development of cementitious materials
… Experimental study was carried out on a mortar slab specimen to verify the model and to investigate the performance of the Smart Probe. It was found that the dynamic modulus of elasticity of the host structure could be predicted from the conductance signatures using the proposed model. …
-
Non-Invasive Permeability Assessment of High-Performance Concrete Bridge Deck Mixtures
… penetrability (ASTM C 1202-97). Laboratory test specimens consisted of two concrete slabs having dimensions of 280 x 280 x 102-mm (11 x 11 x 4-in) and twelve 102 x 204-mm (4 x 8-in) cylinders per concrete mixture. Specimens were tested at 7, 28 and 91-days. Thirteen cylinder specimens per …