Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 121 for “"Slab-Column"”.

  1. Dynamic capacity of isolated slab column specimens

    … By understanding the behavior of these slab-column connections and their response to dynamically applied loads, better predictions and more refined modeling can be done to investigate a structures ability to resist progressive collapse.

    missouri Repository record for Dynamic capacity of isolated slab column specimens (opens in a new tab)

  2. Seismic resistance of fiber-reinforced slab-column connections

    … interior and three exterior fiber reinforced slab-column connections were subjected to gravity loads and then tested under lateral load simulating earthquake forces. Test results were compared to previous tests on non-fiber slab-column connections. Addition of steel fiber to the concrete …

    rice Repository record for Seismic resistance of fiber-reinforced slab-column connections (opens in a new tab)

  3. Inclined shear reinforcement in reinforced concrete slab-column connections

    Reinforced concrete flat slabs are widely used in modern infrastructure. Due to their comparatively simple construction, flat slabs have become especially prevalent in mid- to high-rise buildings. The performance of slab-column connections has been critically studied over the last several decades …

    texas Repository record for Inclined shear reinforcement in reinforced concrete slab-column connections (opens in a new tab)

  4. Seismic response of slab-column connections with shear capitals

    The punching shear strength of the slab usually governs the design of slab-column connections in regions of high seismicity. One method of increasing the shear capacity of the connection region is to increase the thickness of the slab using shear capitals. A shear capital is a thickened portion of …

    rice Repository record for Seismic response of slab-column connections with shear capitals (opens in a new tab)

  5. Seismic Assessment of Slab-Column Connections in Walled Buildings

    … research was the lack of full-scale test data on slab-column (SC) connections when walls are present, as well as the fact that the members used in previous experiments on SC connections were not detailed based on the most recent code provisions. The purpose of this study was to evaluate the …

    tamu Repository record for Seismic Assessment of Slab-Column Connections in Walled Buildings (opens in a new tab)

  6. Behaviour of GFRP-RC slab-column edge connections with openings

    Flat plate Reinforced Concrete (RC) slab-column connections are widely used due to their structural efficiency and architectural advantages. However, these systems are vulnerable to brittle punching shear failure, particularly in edge connections subjected to combined shear and unbalanced moment. …

    manitoba Repository record for Behaviour of GFRP-RC slab-column edge connections with openings (opens in a new tab)

  7. Rehabilitation of reinforced concrete slab-column connections for two-way shear

    … system, it is prone to brittle shear failure at slab-column connections, which may result in the progressive collapse of a building. For that reason, connections with insufficient two-way shear strength may need to be rehabilitated and rehabilitation can be a cost-effective alternative to …

    texas Repository record for Rehabilitation of reinforced concrete slab-column connections for two-way shear (opens in a new tab)

  8. Punching shear behaviour of FRP-reinforced concrete interior slab-column connections

    Flat slab-column connections are common elements in reinforced concrete (RC) structures such as parking garages. In cold weather regions, these structures are exposed to de-icing salts and aggressive environments. Using fiber reinforced polymer (FRP) bars instead of steel in such structures will …

    manitoba Repository record for Punching shear behaviour of FRP-reinforced concrete interior slab-column connections (opens in a new tab)

  9. Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections

    The two-way shear response of slab-column connections has been evaluated by a significant number of experiments. This research documents an updated database of slab-column (SC) connection tests using consistent criteria for selecting key response parameters including the limiting lateral drift …

    tamu Repository record for Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections (opens in a new tab)

  10. Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections

    … that often includes reinforced concrete flat slabs. A major challenge with the design of this system is ensuring adequate strength and deformation capacities of the flat slab-column connections, especially when the structure is prone to strong seismic excitations. When a flat slab-column …

    ubc Repository record for Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections (opens in a new tab) Download PDF for Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections (opens in a new tab)

  11. Effect of Unbalanced Moment on Punching Shear Strength of Slab-Column Joints

    The design of reinforced concrete flat plate slab-column connections subjected to unbalanced moments varies greatly between national design codes. Specific to Canada and the United States (U.S.), assumptions relating to the distribution of unbalanced moments between shear and flexure stresses were …

    waterloo Repository record for Effect of Unbalanced Moment on Punching Shear Strength of Slab-Column Joints (opens in a new tab)

  12. Punching Shear Retrofit of Concrete Slab-Column Connections with GFRP Shear Bolts

    … changes due to material deterioration or damage. Slab-column connections in flat slab structures might need to be strengthened for punching shear. Using steel shear bolts to strengthen connections for punching shear is a new technique used for retrofit that was developed at the University of …

    waterloo Repository record for Punching Shear Retrofit of Concrete Slab-Column Connections with GFRP Shear Bolts (opens in a new tab)

  13. Seismic resistance of slab-column connections in non-ductile flat-plate buildings

    … flat-plate buildings, four reinforced concrete slab-column connection subassemblies designed for gravity load only were built at half-scale of prototype structure, and tested at Ryon laboratory of the Rice University. Each specimen had two exterior and one interior connections. The variables …

    rice Repository record for Seismic resistance of slab-column connections in non-ductile flat-plate buildings (opens in a new tab)

  14. Evaluation of tensile and compressive membrane action in isolated slab column specimen

    … progressive collapse in which the failure of one slab-column connection can propagate to other connections and cause a full collapse of the building. The most common mechanism of failure in flat-plates is known as punching shear, when inclined shear cracks propagate through the depth of the slab …

    missouri Repository record for Evaluation of tensile and compressive membrane action in isolated slab column specimen (opens in a new tab)

  15. Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections

    … provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …

    waterloo Repository record for Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections (opens in a new tab)

  16. Finite Element Analysis of Reinforced Concrete Slab-Column Connections for Seismic Performance Investigation

    In reinforced concrete (RC) flat plate systems, slab-column connections are critical components, susceptible to brittle punching shear failure under seismic actions. The current code provisions for the design of RC flat slabs are generally based on empirical formulations derived from tests, thus, …

    queens Repository record for Finite Element Analysis of Reinforced Concrete Slab-Column Connections for Seismic Performance Investigation (opens in a new tab)

  17. Nonlinear finite element analysis of punching shear of reinforced concrete slab-column connections

    … provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …

    greece Repository record for Nonlinear finite element analysis of punching shear of reinforced concrete slab-column connections (opens in a new tab)

  18. A NEW PUNCHING SHEAR STRENGTHENING TECHNIQUE FOR REINFORCED CONCRETE SLABS AT INTERIOR SLAB-COLUMN CONNECTIONS

    … Shear Bolts is a new approach to strengthening slab-column connections. Reported in this thesis are the results of research on the use of shear bolts for reinforced concrete interior slab-column connections without unbalanced moments. Six slab specimens were tested with different configurations …

    waterloo Repository record for A NEW PUNCHING SHEAR STRENGTHENING TECHNIQUE FOR REINFORCED CONCRETE SLABS AT INTERIOR SLAB-COLUMN CONNECTIONS (opens in a new tab)