Seismic resistance of fiber-reinforced slab-column connections
… interior and three exterior fiber reinforced slab-column connections were subjected to gravity loads and then tested under lateral load simulating earthquake forces. Test results were compared to previous tests on non-fiber slab-column connections. Addition of steel fiber to the concrete …
-
Inclined shear reinforcement in reinforced concrete slab-column connections
Reinforced concrete flat slabs are widely used in modern infrastructure. Due to their comparatively simple construction, flat slabs have become especially prevalent in mid- to high-rise buildings. The performance of slab-column connections has been critically studied over the last several decades …
-
Seismic response of slab-column connections with shear capitals
The punching shear strength of the slab usually governs the design of slab-column connections in regions of high seismicity. One method of increasing the shear capacity of the connection region is to increase the thickness of the slab using shear capitals. A shear capital is a thickened portion of …
-
Seismic Assessment of Slab-Column Connections in Walled Buildings
… research was the lack of full-scale test data on slab-column (SC) connections when walls are present, as well as the fact that the members used in previous experiments on SC connections were not detailed based on the most recent code provisions. The purpose of this study was to evaluate the …
-
Rehabilitation of reinforced concrete slab-column connections for two-way shear
… system, it is prone to brittle shear failure at slab-column connections, which may result in the progressive collapse of a building. For that reason, connections with insufficient two-way shear strength may need to be rehabilitated and rehabilitation can be a cost-effective alternative to …
-
Punching shear behaviour of FRP-reinforced concrete interior slab-column connections
Flat slab-column connections are common elements in reinforced concrete (RC) structures such as parking garages. In cold weather regions, these structures are exposed to de-icing salts and aggressive environments. Using fiber reinforced polymer (FRP) bars instead of steel in such structures will …
-
Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections
The two-way shear response of slab-column connections has been evaluated by a significant number of experiments. This research documents an updated database of slab-column (SC) connection tests using consistent criteria for selecting key response parameters including the limiting lateral drift …
-
Seismic behaviour and nonlinear modeling of reinforced concrete flat slab-column connections
… that often includes reinforced concrete flat slabs. A major challenge with the design of this system is ensuring adequate strength and deformation capacities of the flat slab-column connections, especially when the structure is prone to strong seismic excitations. When a flat slab-column …
-
Punching Shear Retrofit of Concrete Slab-Column Connections with GFRP Shear Bolts
… changes due to material deterioration or damage. Slab-column connections in flat slab structures might need to be strengthened for punching shear. Using steel shear bolts to strengthen connections for punching shear is a new technique used for retrofit that was developed at the University of …
-
Seismic resistance of slab-column connections in non-ductile flat-plate buildings
… flat-plate buildings, four reinforced concrete slab-column connection subassemblies designed for gravity load only were built at half-scale of prototype structure, and tested at Ryon laboratory of the Rice University. Each specimen had two exterior and one interior connections. The variables …
-
Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections
… provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …
-
Finite Element Analysis of Reinforced Concrete Slab-Column Connections for Seismic Performance Investigation
In reinforced concrete (RC) flat plate systems, slab-column connections are critical components, susceptible to brittle punching shear failure under seismic actions. The current code provisions for the design of RC flat slabs are generally based on empirical formulations derived from tests, thus, …
-
Nonlinear finite element analysis of punching shear of reinforced concrete slab-column connections
… provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …
-
A NEW PUNCHING SHEAR STRENGTHENING TECHNIQUE FOR REINFORCED CONCRETE SLABS AT INTERIOR SLAB-COLUMN CONNECTIONS
… Shear Bolts is a new approach to strengthening slab-column connections. Reported in this thesis are the results of research on the use of shear bolts for reinforced concrete interior slab-column connections without unbalanced moments. Six slab specimens were tested with different configurations …
-
Strength and Behavior of Reinforced Concrete Slab-Column Connections Subjected to Static and Dynamic Loadings
Made available in DSpace on 2014-12-10T22:21:27Z (GMT). No. of bitstreams: 1 7114716.pdf: 15433902 bytes, checksum: 732b89ceb8fd2d083a6c493c4f30eea8 (MD5) Previous issue date: 1970
-
Two-way shear strength of reinforced concrete slab-column connections : influence of testing conditions in isolated specimens
… punching shear strength, of reinforced concrete slabs, code provisions fitted from experimental data are typically employed. The experimental data forming the bases of these provisions have generally consisted of isolated slab-column connection tests that seek to represent the negative moment …
-
Evaluation of Nonprestressed and Post-Tensioned Slab-Column Connections Using Experimental Databases and Nonlinear Finite Element Analysis
… experimental research has been conducted on slab-column (SC) connections to improve the understanding of the punching shear behavior, there are a number of parameters that have not been fully evaluated experimentally, particularly for prestressed slabs. Additionally, recommendations in codes …
-
Non-destructive evaluation of gravity load carrying capacity and lateral load damage of reinforced concrete slab-column connections
… to quantify the load carrying capacity of a slab-column connection as a function of the structural damage. To fulfill this objective, guidelines for damage assessment of reinforced concrete flat-plate buildings were developed. The intent of the guidelines was to assist engineers assess …