Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Socket Fit"”.

  1. Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling

    In lower-limb prosthetics, what produces a good-fitting prosthetic socket is loosely defined. Although common socket rectifications are known and the change in residuum volume to create a poor fit has been estimated, determining the quality of a prosthetic fit lies entirely in the hands of the …

    salford Repository record for Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling (opens in a new tab)

  2. Physiological and Mechanical Effects of Prosthetic Elevated Vacuum Systems in People with Transtibial Amputation

    … with a lower limb amputation is maintaining socket fit. Long-term and short-term changes of residual limb volume can alter socket fit resulting in pain, skin breakdown, or falls. Several strategies are used to accommodate the lost volume; however, many of these reduce the size of the socket …

    washington Repository record for Physiological and Mechanical Effects of Prosthetic Elevated Vacuum Systems in People with Transtibial Amputation (opens in a new tab)

  3. Upper limb prosthetic socket-limb coupling: Novel measurement approaches and impacts on socket performance and comfort

    … and emerging interest in adjustable prosthetic sockets offer the potential to deliver better fitting sockets but design methods remain limited. Design approaches are limited by current understanding of how to define and evaluate socket fit, which in turn makes it difficult to explore …

    salford Repository record for Upper limb prosthetic socket-limb coupling: Novel measurement approaches and impacts on socket performance and comfort (opens in a new tab) Embargoed until 2026-11-23

  4. Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics

    … satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks …

    calpoly Repository record for Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics (opens in a new tab)

  5. A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use

    … tissue of the residual limb. As prosthesis socket fit is considered one of the most integral elements of increasing the likelihood a user adopts their artificial limb, it is crucial to understand how the limb interacts with the prosthesis at the contact interface. The individualized nature …

    washington Repository record for A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use (opens in a new tab)

  6. A quantitative fluoroscopic study of the relationship between lumbar inter-vertebral and residual limb/socket kinematics in the coronal plane in adult male unilateral amputees. (Exploring the spine and lower limb kinematics of trans-tibial amputees).

    … stability and the motion between the prosthetic socket and residual limb. It is hoped that these investigations will improve understanding of the importance of limb-socket fit to the functional integrity of the lumbar spine in lower limb amputees Methods A literature review and three preliminary …

    bournemouth Download PDF for A quantitative fluoroscopic study of the relationship between lumbar inter-vertebral and residual limb/socket kinematics in the coronal plane in adult male unilateral amputees. (Exploring the spine and lower limb kinematics of trans-tibial amputees). (opens in a new tab)

  7. Inter- and intra socket shape and volume consistency assessed using magnetic resonance imaging for hands-on and hands-off casting of amputee below knee sockets

    … has a great influence on the quality of socket fit. Investigations into the shape and volume of trans-tibial prosthetic sockets are complicated due to the difficulty in establishing an accurate reference grid. The use of Magnetic Resonance Imaging (MRI) presents a possible solution to …

    strathclyde Repository record for Inter- and intra socket shape and volume consistency assessed using magnetic resonance imaging for hands-on and hands-off casting of amputee below knee sockets (opens in a new tab)

  8. Trans-tibial prosthetic system design and benefits for the amputee, service providers and society : an evidence based clinical study

    Two trans-tibial socket concepts are in regular use in prosthetic clinics. These may be categorised as the "hands-on" (hand casting) concept and "hands-off' (pressure casting) concept which, in addition to the distinctive casting methods, require different liner materials and components to create …

    strathclyde Repository record for Trans-tibial prosthetic system design and benefits for the amputee, service providers and society : an evidence based clinical study (opens in a new tab)

  9. Trans-radial Socket Coupling Problems And Solutions

    … little research into the assessment of socket fit in upper-limbprosthetics, in comparison to lower-limb prosthetics. Whilst this reflects the smallerpopulation of potential users, the global need for devices is nonetheless substantial. Themeasurement of socket fit was explored through a …

    salford Repository record for Trans-radial Socket Coupling Problems And Solutions (opens in a new tab)

  10. Finite Element Modelling of Residual Limb and Transtibial Prosthesis Socket to Predict Interfacial Pressure Considering Muscle Contraction

    … that interfaces with the residuum (the "socket") must be designed to fit properly not only at rest but also during walking and other daily activities. The shape of the residuum changes during movement as muscles contract, which can affect the fit of the socket. To study the …

    ottawa-retro Repository record for Finite Element Modelling of Residual Limb and Transtibial Prosthesis Socket to Predict Interfacial Pressure Considering Muscle Contraction (opens in a new tab)

  11. Design and analysis of a volume adjustable transtibial prosthetic socket for pediatric amputees in developing countries

    … a lack of medical services, maintaining proper socket fit is a challenging but necessary endeavor. A socket design that adjusts for radial and longitudinal growth will allow patients to wear the same socket for a longer period of time saving them the expense of subsequent fittings and hardware. …

    texas Repository record for Design and analysis of a volume adjustable transtibial prosthetic socket for pediatric amputees in developing countries (opens in a new tab)

  12. Rule based behavior classification via accelerometry in transtibial amputees

    … activity modulates residual limb volume and socket fit. There are currently very few systems available which capture general long-term amputee behavior and so a computer algorithm for categorizing activity data is developed and validated. An accelerometer is fixed to the prosthesis pylon and …

    washington Repository record for Rule based behavior classification via accelerometry in transtibial amputees (opens in a new tab)

  13. Transtibial Prosthesis Insert to Accommodate Residual Limb Volume Change

    … amputations often require multiple prosthetic sockets to accommodate changes in residual limb volume and shape. This frequent need for new sockets arises as the limb matures, posing a challenge for both amputees and prosthetists. Digital manufacturing technologies offer promising solutions to …

    ottawa-retro Repository record for Transtibial Prosthesis Insert to Accommodate Residual Limb Volume Change (opens in a new tab)

  14. Towards Developing a Digital Workflow for Transradial (Below-Elbow) Prostheses

    … improve patient care. Despite the promising benefits, over half of O&P clinicians do not utilize digital technology due to various technical and economical factors, indicating that perceived advantages have yet to outweigh existing limitations. Addressing these challenges is crucial to foster the …

    toronto-retro Repository record for Towards Developing a Digital Workflow for Transradial (Below-Elbow) Prostheses (opens in a new tab)

  15. Measurement of factors affecting fit at the prosthetic socket-residual limb interface in people with transtibial amputation

    Many people with transtibial amputation rate the fit between their residual limb and prosthetic socket as the most important factor in the use of their prosthesis. Current research suggests that poor fit between the residual limb and the prosthetic socket can cause pain, skin breakdown or …

    unsw Repository record for Measurement of factors affecting fit at the prosthetic socket-residual limb interface in people with transtibial amputation (opens in a new tab)

  16. Development of a biomechanical model of the interface between the residual limb and prosthesis for trans-femoral amputees

    Prosthetic socket fitting is achieved by the prosthetist applying artisan techniques which are skill dependent and of subjective nature.This study investigates the use of finite element (FE) modelling techniques to predict the biomechanical behaviour at the residual limb / socket interface for the …

    strathclyde Repository record for Development of a biomechanical model of the interface between the residual limb and prosthesis for trans-femoral amputees (opens in a new tab)

  17. Testing of an Electronic Controlled Prosthetic System to Reduce Volume Limb Loss

    … to a loss of orientation control, uncomfortable socket fit and possibly limb tissue damage. Vacuum control is the leading method for dealing with the limb shrinkage but lacks fine control. The system proposed uses electromagnets to add regional control while also being used to help with …

    hawaii Repository record for Testing of an Electronic Controlled Prosthetic System to Reduce Volume Limb Loss (opens in a new tab)

  18. Electromagnetic suspension system for prosthetic limbs that compensates for residual limb shrinkage

    … such as damage to the limb and an uncomfortable socket fit. Currently, vacuum suspension is the leading method to compensate for limb volume changes. However, vacuum suspension has many flaws as well. There is a need for a new prosthetic suspension system with the capability to adjust and control …

    hawaii Repository record for Electromagnetic suspension system for prosthetic limbs that compensates for residual limb shrinkage (opens in a new tab)

  19. Bioimpedance Analysis to Determine the Effect of Pressure Release on Limb Fluid Volume Change in Persons with Transtibial Limb Loss

    … designed to produce a secure and comfortable fit between residual limb and prosthesis throughout the day. However, significant fluid volume fluctuations in the residual limb deteriorate socket fit and may cause decreased mobility due to discomfort or soft tissue injury from increased pressures …

    washington Repository record for Bioimpedance Analysis to Determine the Effect of Pressure Release on Limb Fluid Volume Change in Persons with Transtibial Limb Loss (opens in a new tab)

  20. Biomechanical analysis of the lower limb amputee socket interface

    The lower limb prosthetic socket provides a critical interface, which transfers loads between the ground and the residuum. Many amputees report issues related to residuum pain primarily induced by poor socket fit, leading to unsatisfactory rehabilitation outcomes. From a scientific perspective, …

    soton Download PDF for Biomechanical analysis of the lower limb amputee socket interface (opens in a new tab)

Page 1 of 2