Biomechanical analysis of the lower limb amputee socket interface
The lower limb prosthetic socket provides a critical interface, which transfers loads between the ground and the residuum. Many amputees report issues related to residuum pain primarily induced by poor socket fit, leading to unsatisfactory rehabilitation outcomes. From a scientific perspective, …
-
Pressure distribution at the stump socket interface in trans-tibial amputees
… However, an ideal patellar tendon bearing socket is one which has an even pressure distribution and at the same time the sensitive areas of the stump are adequately guarded. Although many studies have been carried out to investigate the pressure distribution at the stump socket interface, …
-
A synergistic approach to transtibial socket interface mechanics : experiments and modeling
… occurring at the residual limb to prosthetic socket interface. Deep penetrating ulcers can form on the residual limb within the socket and the formation is not understood in the current research regarding interface mechanics. Quantitative data on limb motion within the socket, shear forces at …
-
Investigating the mechanisms of soft tissue damage at the residual limb-socket interface
… below knee amputation form a critical loaded interface with the prosthetic limb. In the early stages of rehabilitation, residual limb tissues have not been conditioned to support loading and are vulnerable to damage. This impacts upon quality of life and can lead to rejection of the …
-
A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use
… tissue of the residual limb. As prosthesis socket fit is considered one of the most integral elements of increasing the likelihood a user adopts their artificial limb, it is crucial to understand how the limb interacts with the prosthesis at the contact interface. The individualized nature …
-
A Smart Prosthesis Socket Liner to Address Factors That Lead to Prosthesis Abandonment
… and characterization of the smart prosthesis socket liner, a soft-robotic prosthesis liner, was presented. This novel robotic system was intended to improve the quality of life for transradial amputees and strived to decrease the rate of prosthesis abandonment. This novel socket liner used …
-
The effect of transverse rotation and longitudinal translation between prosthetic components during the gait of unilateral trans-tibial amputees
… forces are transmitted across the residual limb socket interface. These loads and associated gait patterns can be altered by introducing compliant elements into the prosthesis. However, previous studies have failed to adequately describe the effects that components with such compliances have on …
-
Finite Element Modelling of Residual Limb and Transtibial Prosthesis Socket to Predict Interfacial Pressure Considering Muscle Contraction
… tissue damage, the part of the prosthesis that interfaces with the residuum (the "socket") must be designed to fit properly not only at rest but also during walking and other daily activities. The shape of the residuum changes during movement as muscles contract, which can affect the fit of the …
-
A study of the parameters and stipulations involved in the design of prosthetic limb socket liners
… the elements necessary for an optimal prosthetic socket interface design. Previous studies have revealed that the industry is manufacturing materials that are causing irregularities in gait patterns and causing major discomfort for transtibial amputees. As a result, chances for recovery and …
-
Quantification of Transhumeral Prosthetic Socket Residual Limb Interface Movement Using Motion Capture and a Slip Detection Sensor
Current literature focusing on the prosthetic socket is limited by measurement techniques and modeling assumptions, leading to a limited understanding of the forces and motions occurring between the residual limb and prosthesis and how they can be used to influence socket design and fitting. …
-
Interface sensor systems for upper limb prosthetics
… monitoring of pressure and shear at the interface between the fingers and objects. Although some pressure sensors are available, little work has been reported on sensor systems capable of simultaneous measurement of pressure and shear, despite the fact that shear monitoring is crucial in …
-
Multiple robot command and control architecture development
… built from Nomadic SCOUT mobile robots and a socket interface. Results from simulation and physical experiments validate the effectiveness of SLEEP for multiple robot coordination.
-
Fully Integrated Slippage Detection System for Lower Limb Amputees
… as improper fit can lead to slippage at the limb-socket interface, resulting in discomfort, pressure sores, and long-term musculoskeletal complications. To address this issue, a fully integrated slippage detection system was developed to monitor an amputee’s daily activities and slippage …
-
IN VIVO MECHANICAL AND PHYSIOLOGICAL CHARACTERISATION OF LOWER LIMB SOFT TISSUE BY A LOCAL INDENTATION TECHNIQUE
… of the bulk soft tissue for future stump socket interface finite element modelling. In vivo indentation experiments were carried out on lower limbs of 2 amputees and 3 normal subjects wearing individual RMM prosthetic sockets and braces respectively, using a custom designed indentation …
-
Taming latency in data center applications
… by redesigning a protocol stack to provide an interface for the latency-sensitive operation, and redesigning synchronous operation such as TLB shootdown and consensus in the operating systems and distributed systems respectively. First, the dissertation presents an extensible protocol stack, …
-
Remote application support in a multilevel environment
… process family is introduced to provide a pseudo-socket interface for the single level remote application to access the MLS LAN interface. Detailed design specifications were created to facilitate implementation of the remote application support.
-
A study of the interface stresses in trans-tibial sockets : a comparison of PTB and hydrocast sockets
… as applied by a Patellar Tendon Bearing (PTB) socket, was based on logical biomechanical principles. (Radcliffe and Foort, 1961) Inconsistencies during rectification of the PTB cast remain a source of error during production of a socket. Kristinsson (1992) described the use of the Icelandic …
-
Study of the pressure distribution at the prosthesis/stump interface of a new design of socket : a pilot study
… part of a trans-femoral prosthesis is the socket. It has to transfer the load generated during gait from the ground to the stump in a comfortable way. Several socket designs for trans-femoral amputees have appeared over the past half century, which have addressed many factors such as …
-
Algorithm to Automatically Generate Multi-Modal Interfaces for Hand Held Devices Based on User Preferences and Abilities
… that provide protocols for describing a user interface socket. The specifications within this standard provide the opportunity for future entertainment equipment such as TVs, VCRs and home theatre systems to be controlled using a single programmable remote control known as a Universal Remote …
-
Performance evaluation of an ensemble neural network system of estimating transtibial prosthetic socket pressures during standing, walking and condition perturbation.
Providing suitable prosthetic sockets for the restoration of function following lower-limb amputation remains a significant issue in medical device prescription. Poorly designed sockets are associated with discomfort, poor quality function and injury, with quality linked to the capability of the …