Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"Sodium iodide detector"”.

  1. Assessing internal contamination after a radiological dispersion device event using a 2x2-inch sodium-iodide detector

    … of using readily available standard 2x2-inch sodium-iodide detectors to determine the committed effective dose to a patient following the inhalation of a radionuclide has been investigated. The 2x2-NaI(Tl) detector was modeled using the Monte Carlo simulation code, MCNP-5, and was validated …

    gatech Repository record for Assessing internal contamination after a radiological dispersion device event using a 2x2-inch sodium-iodide detector (opens in a new tab)

  2. Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector

    … metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument. The calibration source was designed in collaboration with Sandia National Laboratory using the Monte Carlo N-Particle eXtended (MCNPX) transport code. The x ray production was maximized while …

    tamu Repository record for Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector (opens in a new tab)

  3. Gamma rays associated with neutron scattering in fusion reactor materials

    … using a gamma-ray spectrometer employing a sodium iodide scintillation detector. The source neutrons are produced by the T(d,n)4He reaction using the SAMES accelerator at the University of Aston in Birmingham. In order to eliminate the large gamma-ray background and neutron signal due to the …

    aston Download PDF for Gamma rays associated with neutron scattering in fusion reactor materials (opens in a new tab)

  4. A Study of the Gamma-Rays Associated with the Inelastic Scattering of Neutrons in Extended Target Samples

    … using a gamma-ray spectrometer employing a sodium iodide scintillation detector. The source neutrons are produced by the T(d,n)"He reaction using the Radiation Centre Dynamitron and.the SAMES accelerator. In order to overcome the large gamma-ray background and large stray neutron signal due …

    aston Repository record for A Study of the Gamma-Rays Associated with the Inelastic Scattering of Neutrons in Extended Target Samples (opens in a new tab) Download PDF for A Study of the Gamma-Rays Associated with the Inelastic Scattering of Neutrons in Extended Target Samples (opens in a new tab)

  5. Experimental Determination of Shielding Requirements for PET Medical Facilities

    … from the patient, detection efficiency of the sodium iodide detector at different energies, and normalized to an injected activity of 15 mCi. The counts were summed to produce a measure of the quantity of transmitted radiation. The shielded wall sums were divided by the unshielded wall sums to …

    uab Repository record for Experimental Determination of Shielding Requirements for PET Medical Facilities (opens in a new tab)

  6. Measurements of Continuous X-Ray Spectra with a Scintillation Spectrometer

    … it was necessary to place the thallium-activated sodium-iodide detector 50 meters from the target. Since the air attenuation was quite large, measurements were made both in air and in helium. In order to contain the helium, an Orangeburg pipe was employed, and its effect on the spectra was …

    unm Repository record for Measurements of Continuous X-Ray Spectra with a Scintillation Spectrometer (opens in a new tab)

  7. Identification and calculation of activity of unknown isotope from spectral analysis in a radiological dispersion device (RDD) incident

    … for further treatment. A portable 3 by 3 NaI detector, which is widely available at most universities, was studied as a tool to identify and calculate the activity of unknown radioisotopes for such an RDD event.

    gatech Repository record for Identification and calculation of activity of unknown isotope from spectral analysis in a radiological dispersion device (RDD) incident (opens in a new tab)