Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Soft Story"”.
-
Sustainability and Resiliency Comparison of Soft-Story Wood-Frame Building Retrofits
Soft-story wood-frame buildings have been identified as a major issue of disaster preparedness. Both the City of San Francisco and the City of Los Angeles have mandated retrofit of these building types. Thus an abundance of research is being conducted on soft-story retrofits. Two popular design …
-
Seismic Analysis of Light-Frame Wood Building with a Soft-Story Deficiency
… have a structural deficiency known as the "œsoft-story". These soft-story buildings often feature an open floor plan with first story for use as parking garage or commercial retail spaces. These soft-story buildings typically have large openings in the exterior walls and no or little …
-
TORSIONAL EFFECT ON SOFT STORY FOR LIGHTLY REINFORCED CONCRETE STRUCTURES IN LOW SEISMIC ZONES
… for gravity loads only. Nonlinear time history analysis using scaled ground motions and pushover procedure as a supplement method are performed in this study. With the adoption of plastic hinge method, damage levels are addressed according to FEMA 356 definitions. Pivot model is considered …
-
Seismic Rehabilitation of Steel Moment Frames Vulnerable to Soft-Story Failures Through Implementation of Rocking Cores
… steel moment frame building systems may exhibit soft-story failures. This thesis focuses on development and validation of a seismic retrofit strategy for avoiding soft-story failures in low-rise and mid-rise steel moment frame buildings. The considered retrofit strategy consists of a sufficiently …
-
Seismic Rehabilitation of Steel Concentrically Braced Frames Vulnerable to Soft-Story Failure Through Implementation of Rocking Cores
… the code-compliant ones) may be susceptible to soft-story failures during strong earthquakes. Such a failure mode causes catastrophic outcomes and should be definitely avoided in practice. This thesis focuses on development and validation of a seismic retrofit strategy for low-rise and mid-rise …
-
Soft-story inerter vibration absorbers for seismic response mitigation of buildings: Conceptualisation, optimal design, and numerical assessment
… viewpoint, leveraging local structural soft-storey design to enhance the TMDI seismic motion mitigation capability, while maintaining linear structural behaviour. Comprehensive analytical and numerical work is undertaken to demonstrate the improved level of seismic building protection …
-
Performance-based seismic retrofit (PBSR) methodology for multi-story buildings with full-scale experimental validation
… older buildings that are code-deficient such as soft-story wood-frame buildings. Many retrofit procedures have been proposed by the research and structural engineering communities including force-based and performance-based retrofit methodologies. A performance-based seismic retrofit (PBSR) …
-
NONLINEAR NUMERICAL SIMULATION STUDY AND REGIONAL-SCALE SEISMIC RESILIENCE ASSESSMENT OF DEFICIENT WOOD-FRAME STRUCTURES RETROFITTED WITH SELF-CENTERING VISCOELASTIC DAMPERS
… and are considered as wood-frame buildings with soft story deficiency. Such residential buildings with three- and four-story are particularly common in the United States. Recent advancements in seismic design have led to the development of various innovative seismic protection strategies. …
-
STUDY OF THE SEISMIC BEHAVIOUR OF REINFORCED CONCRETE FRAMES HAVING VERTICAL IRREGULARITIES
… DUCTILITY. COVERED IN THIS THESIS ARE TWO SIX-STORY THREE-BAY FRAMES, ONE HAVING A TALL FIRST STORY (FRAME BF 1), AND THE OTHER HAVING A DISCONTINUING COLUMN (FRAME DCF). THE FRAMES WERE DESIGNED IN THEIR PROTOTYPE SCALE IN ACCORDANCE WITH EC8, AND THEIR 1 /5.5TH SCALE MODELS WERE CONSTRUCTED …
-
Evaluation of Seismic Assessment Procedures for Existing Reinforced Concrete Structures Damaged in the 2016 Meinong Earthquake
… most commonly observed response mechanism was soft-story resulting from apparent shear and/or flexure-shear damage to the first story. The initial phase of the study employed triage-type procedures, including the well-established ASCE 41 Tier 1 (preliminary screening) and a new process funded …
-
Performance-based Seismic Design of Multi-Story Light-frame Wood Buildings using Adaptive Displacement-based Design Procedure
… in many light-frame wood buildings, namely soft first-story damage, and, in some extreme cases, pancake collapse. Many buildings have a soft first-story because of an open-space floor plan used for retail or parking with minimal partition walls while the upper stories are apartment units. …
-
DYNAMIIC RESPONSE OF FRAME-CORE WALL TALL BUILDINGS TO WIND LOAD
… a special case, the behaviors of structure with soft story are also studied based on the proposed method.
-
UNDERSTANDING AND IMPROVING THE DYNAMIC PERFORMANCE OF THE STRONGBACK STRUCTURAL SYSTEM
… Strongback systems are designed to mitigate soft-story collapse by promoting a uniform story drift profile. While these systems offer promising improvements to seismic resilience, important questions remain regarding their robustness and effectiveness under varying structural and seismic …
-
Seismic Resilience Study of Steel Concentrically Braced Frame Structure with Dual Viscous and Metallic Hysteretic Damper
… However, conventional CBFs are subject to soft-story damage pattern which may lead to collapse caused by overly large drift concentrated in one story in strong earthquakes; measures to enhance the seismic resilience of CBFs is thus desirable. This study looks into quantifying the seismic …
-
A new energy absorber for earthquake resistant buildings
… has been studied as an absorber of a first soft story method. The first soft story is one of the ideas which has been presented for the isolation of buildings from earthquake effects, however, no proper absorber has been suggested to be used in this method. This device has an excellent …
-
Strategies for rapid seismic hazard mitigation in sustainable infrastructure systems
… showed the ability of the system to minimize soft story failures. Both techniques can be implemented within a sustainability framework, as these interventions reduce the seismic vulnerability of infrastructure, are low cost, utilize materials and fabrication processes widely available …
-
Studies on the Design and Behavior of Strongback Braced Frames
… steel braced frames are vulnerable to soft-story mechanisms, whereby the weakest story accumulates more damage relative to the rest of the structure. This reduces the overall strength of the structure and increases the cost of repairs.</p> <p>One method for mitigating this behavior is …
-
Capacity design methods for strongback braced frames
… steel braced frames are vulnerable to soft-story mechanisms, whereby the weakest story accumulates more damage relative to the rest of the structure. This reduces the overall strength of the structure, increases the cost of repairs, and can cause issues during the design process due to …
-
A multi-objective community-level seismic retrofit optimization combining social vulnerability with an engineering framework for community resiliency
… extensive numerical study using nonlinear time history analysis. Experimental testing was conducted at full scale on a three-story soft-story woodframe building. The experimental testing investigated the seismic performance of several retrofit strategies for use in the framework, and the results …
-
Bending Response of Timber Mortise and Tenon Joints Reinforced with Filler-Modules and FRP Gussets
… to ensure that their 10,000 plus timber soft-story buildings were prepared for seismic events, through nondestructive evaluation methods. Many property owners are searching for an affordable retrofitting system that will also meet CBA’s new laws focusing on installations by the mandated …
Page 1 of 2