Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 14 of 14 for “"Soft Tissue Artifact"”.
-
Investigation of a Double Calibration Technique to Reduce Soft Tissue Artifact Error in High Flexion
… because of an inherent source of error known as soft tissue artifact (STA). This error is defined as the movement of skin markers relative to the underlying bone and affects the thigh markers more than the shank. It cannot be filtered out of data after processing because it has a similar …
-
Triangular Cosserat Point Element Method for Reducing Soft Tissue Artifact: Validation and Application to Gait
… of the markers during motion. Skin and adipose tissue move independently of the underlying bone during motion creating error known as soft tissue artifact (STA), the primary source of error in human motion capture (Leardini et al., 2005). (Solav et al., 2014) proposed and (Solav et al., 2015) …
-
An Investigation of Methods to Attenuate Soft Tissue Artifact of the Thigh in High Knee Flexion
Soft tissue artifact during optical motion capture, or the movement of skin markers relative to bone, is widely accepted as a significant source of error in estimations of angles and moments. In some cases, the error associated with soft tissue movement exceeds that of the physiological motion of …
-
The Application of Post-hoc Correction Methods for Soft Tissue Artifact and Marker Misplacement in Youth Gait Knee Kinematics
… Cosserat Point Element (TCPE) analysis for Soft-Tissue Artifact (STA) correction of knee kinematics with youth participants, and (3) develop a code to conduct a Principal Component Analysis (PCA) to find the PCA-defined flexion axis and calculate knee angles with both STA and PCA-correction …
-
A Patient-Specific Knee Model Driven by In Vivo Kinematics to Better Represent an ACL-Injured Pediatric Population
… this difference; however, due to the presence of soft tissue artifact, marker translation may exceed the physiological range of the knee itself. Using OpenSim, the range of motion of the knee was constrained to allow for soft tissue artifact to be reduced. Therefore, the two objectives of this …
-
Quantifications and characteristics of dynamic soft tissue artifacts captured by wearable inertial measurement unit sensors
… However, wearable sensors are often worn on soft tissue that is excited during impulsive impacts, producing dynamic soft tissue artifact measurement errors. This thesis quantifies the error caused by dynamic soft tissue artifacts to IMU sensors with different sensor mass and placement when …
-
Analysis of Gait Parameters and Knee Angles in Ultimate Frisbee Players: Implications for Balance and Injury
… Cosserat Point Element (TCPE) analysis for Soft-Tissue Artifact (STA) correction of knee kinematics. The gait parameters and knee angles were compared between ultimate players and control group participants using two-sample t tests. The results indicated that (1) playing ultimate may be used …
-
Is my musculoskeletal model complex enough? The implications of six degree of freedom lower limb joints for dynamic consistency and biomechanical relevance
… that modeling errors due to unaccounted for soft-tissue deformations – known as soft-tissue artifact (STA) – can reduce the efficacy and usefulness of musculoskeletal simulations. Recent work has proven that adding degrees of freedom (DOF) to the joint definitions of a musculoskeletal model’s …
-
The Effects of Obesity on Resultant Knee Joint Loads for Gait and Cycling
… is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking …
-
Foot and Ankle Motion Analysis Using Dynamic Radiographic Imaging
… but suffer from errors associated with soft tissue artifact, marker placement repeatability, and rigid segment assumptions. Models using intra-cortical bone pins circumvent these errors, but their invasive nature has limited their application to research only. Radiographic models …
-
Modelling Soft-Tissue Motion During Human Movement Experiments to Improve Calculations of Skeletal Kinematics
… to the underlying bones. These errors, known as soft-tissue artifacts, lead to uncertainty in the calculation of bone locations and, consequently, uncertainty in the computed skeletal joint angles. This uncertainty limits the use of inverse kinematic simulations in clinical settings. Given the …
-
Predicting Muscle Activations in a Forward-Inverse Dynamics Framework Using Stability-Inspired Optimization and an In Vivo-Based 6DoF Knee Joint
Modeling and simulations are useful tools to help understand knee function and injuries. As there are more muscles in the human knee joint than equations of motion, optimization protocols are required to solve a problem. The purpose of this thesis was to improve the biofidelity of these simulations …
-
Advanced methods for human movement analysis in biomechanics based on functional algorithms and multibody modelling
… At this stage, also the huge problem of soft tissue artifact is faced up by means of optimization techniques allowing to compensate it, as well to proceed with the following joints kinematics computation. Results are provided in terms of accuracy, precision and repeatability of joints …
-
Development of a full flexion 3D musculoskeletal model of the knee considering intersegmental contact and deep muscle activity during high knee flexion
… of knee motion as pressure sensor technology and soft tissue artifact are considerable limitations. Measurement of populations who habitually perform these activities needs to be completed to assess the translation of these findings to appropriate individuals.