Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 28 for “"Solenoidal Tracker at RHIC"”
-
Scintillation detector development for the solenoidal tracker at RHIC (STAR) and the CEBAF large acceptance spectrometer (CLAS)
… some of the physics and mechanics of scintillation detection, results of the development for the Central Trigger Barrel (CTB) for STAR and the Start Counter for CLAS are discussed. For the CTB development, 1 cm x 20 cm x 100 cm scintillators were studied with light guides of various geometries …
-
A large area time of flight detector for the STAR experiment at RHIC
… (TOF) detector based on multi-gap resistive plate chamber (MRPC) technology has been developed for the STAR (Solenoidal Tracker at RHIC) experiment at the Relativistic Heavy Ion Collider at the Brookhaven National Laboratory, New York. The TOF detector replaces STAR's Central Trigger Barrel …
-
Calibration study on a prototype of the Muon Telescope Detector at STAR of RHIC
… the Muon Telescope Detector (MTD) was installed at STAR (Solenoidal Tracker at RHIC) during run year 2007. While the cosmic and beam tests showed a ~ 60 - 70 ps timing resolution for MTD, the actual performance in Au + Au collisions at STAR was found ~300 ps. In run year 10 STAR implemented a new …
-
Calibration of the STAR Time-of-Flight Detector for Particle Identification
This thesis describes several calibrations of the Time-of-Flight (TOF) detector at the Solenoidal Tracker at RHIC (STAR). These calibrations are required to allow Particle Identification (PID) which benefits many physics analysis. These calibrations treat the Integral Non-Linearity (INL) of the …
-
Construction of a new detector, and calibration strategies, for start timing in the STAR experiment at RHIC
The Time of Flight (TOF) system of the Solenoidal Tracker at RHIC (STAR) at the Relativistic Heavy Ion Collider (RHIC) consists of two different subsystems: the start detector and the stop detector. Described in this thesis is the design, construc tion, and operation of a new start detector for …
-
Measurement of the Longitudinal Double-Spin Asymmetry of Jets and Dijets at Mid-Rapidity at √s = 200 GeV at STAR
… the use of the unique capability of the Relativistic Heavy-Ion Collider (RHIC) to collide polarized protons at √s = 200 GeV and √s = 510 GeV. The kinematic coverage of the Solenoidal Tracker At RHIC (STAR) allows access to gluons through quark-gluon and gluon-gluon scattering processes which …
-
Dijet production in polarized proton-proton collisions at [the square root of sigma] = 200 GeV
Polarized deep inelastic scattering (DIS) experiments indicate that quarks only carry approximately 30% of the proton spin, which led to interest in measuring the contributions of other components. Through polarized proton-proton collisions at the Relativistic Heavy Ion Collider (RHIC), the world's …
-
Electron positron pair production in ultraperipheral Au+Au collisions at RHIC
… The collisions were observed in runs 10 and 11 at the Relativistic Heavy Ion Collider (RHIC), using the Solenoidal Tracker at RHIC (STAR detector).|Ultraperipheral collisions occur when the distance of closest approach between the centers of two nuclei is slightly larger than the sum of the two …
-
Statistical moments of the multiplicity distributions of identified particles in Au+Au collisions
… point (CP) in the phase diagram of hot nuclear matter, a beam energy scan was performed at the Relativistic Heavy-Ion Collider at Brookhaven National Laboratory. The Solenoidal Tracker at RHIC (STAR) collected Au+Au data sets at beam energies, √sNN , of 7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV. …
-
Long-Range Pseudorapidity Correlations at High pT in sqrt(S_NN) = 200 GeV Au+Au Collisions with STAR
The Quark Gluon Plasma (QGP) is a form of matter in which quarks and gluons are deconfined, and was suggested to be formed in high-energy heavy-ion collisions. Since the discovery of high-pT hadron suppression in central Au+Au collisions at the Relativistic Heavy Ion Collider (RHIC), and the …
-
2d DI-HADRON CORRELATION AT √SNN = 200 GeV USING THE STAR EXPERIMENT
The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL) in Long Island, New York, attempts to recreate the initial conditions at the birth of our universe. Heavy Au ions are accelerated up to 0.99995c and collided at √SNN = 200 GeV (center of mass energy per nucleon) in order to …
-
Heavy Quarkonium Production at sqrt{s_{NN}} = 200 GeV
… Color Octet Model (COM). Previous measurements at the Tevatron collider by the CDF and D0 experiments are not fully in agreement with predicted observables from either model. The Relativistic Heavy Ion Collider (RHIC), and the Solenoidal Tracker At RHIC (STAR) is well suited to further explore …
-
Measurement of Polarized Proton-Proton Elastic Scattering at the Relativistic Heavy Ion Collider (RHIC)
Elastic proton-proton (pp) scattering is one of the most fundamental processes in nature and yet, it is one of the most difficult to describe. There are two interactions involved in this process: electromagnetic (Coulomb) and hadronic (strong) interactions. Underlying exchange mechanisms of these …
-
The radiance of the gluon spin : constraining the proton spin structure with the direct photon double helicity asymmetry
… universe, the proton is not elementary. Rather the particle is a bound state of three valence quarks and the QCD vacuum that condenses around them, its properties an amalgamation of those underlying degrees of freedom. Naive expectations presume that contributions from the valence quarks …
-
Spin Dependence in Polarized Proton-Proton Elastic Scattering at RHIC
The STAR (Solenoidal Tracker At RHIC - Relativistic Heavy Ion Collider) experiment is equipped with Roman Pots, insertion devices that allow detectors to be moved close to the beam for the measurement of high energy protons scattered at very small angles. This setup, together with the unique …
-
Resonance particles in heavy-ion collisions
Heavy ions are collided at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) in an effort to create a unique state of nuclear matter, where quarks and gluons can freely move over volumes larger than the typical size of a nucleon (typical scale of Quantum …
-
Sequential Strangeness Freeze-out via Statistical Hadronization in Relativistic Heavy Ion and Elementary Particle Collisions
… between quarks and gluons, suggests that the coupling strength of the strong interaction asymptotically decreases at large momentum scales. Hence, at large enough densities and/or temperatures – like the conditions present in the early Universe – the quarks and gluons composing hadrons …
-
THE FIRST HARMONIC ANISOTROPY OF CHARMED MESONS IN 200 GEV AU+AU COLLISIONS
At the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL), Long Island, NY, the main goal of research into heavy-ion collisions has been to understand Quantum Chromo Dynamics (QCD) in conditions of extreme temperature and energy density. At ordinary temperatures, the …
-
Non-photonic Electron Distributions at Pseudo-rapidities Between 1.1 and 1.5 in Proton-Proton Collisions at √s=200 GeV at Relativistic Heavy Ion Collider
<p>This Dissertation project involved using the Endcap Electro-Magnetic Calorimeter (EEMC) to try to measure charm quark production in proton-proton (p+p) collisions at √s=200 GeV. This was performed by identifying electrons produced in the decay of charm D<sup>0</sup> mesons. This project included …
-
AZIMUTHAL ANISOTROPY IN HEAVY ION COLLISIONS
STAR (Solenoidal Tracker At RHIC) is one of two large detectors along the ring of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. Experiments that collide heavy nuclei at high energy have been taking data at RHIC since the year 2000. The main goal of RHIC has been to …
Page 1 of 2