Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 70 for “"Solid Sample"”

  1. Solid sample introduction in inductively coupled plasma emission spectrometry.

    … describes the progress made in the area of solid sample introduction in Inductively Coupled Plasma Emission Spectrometry (ICP-ES). As an alternative to solution nebulisation two methods of introducing samples to the ICP are investigated. The first of these uses the direct insertion probe …

    sheffield-hallam Repository record for Solid sample introduction in inductively coupled plasma emission spectrometry. (opens in a new tab)

  2. Cold fiber solid phase microextraction in solid sample analysis

    The cold fiber solid phase microextraction (SPME) system was improved by minimizing the coating temperature fluctuation range, and the performance of the system was evaluated by investigating the extraction of PAHs from spiked sand samples. The coating temperature can be made relatively constant …

    waterloo Repository record for Cold fiber solid phase microextraction in solid sample analysis (opens in a new tab)

  3. Investigations of Ice Photodynamics: Molecular Dynamics Studies and an Apparatus for Solid Sample Velocity Map Imaging

    … to investigate photodynamics in amorphous solid water (ASW), ice XI, and ice Ih. Additionally, results from a velocity map imaging apparatus, which has been augmented for the study of low temperature solid samples, are presented. Specifically, preliminary results for NO2:Ar …

    queens Repository record for Investigations of Ice Photodynamics: Molecular Dynamics Studies and an Apparatus for Solid Sample Velocity Map Imaging (opens in a new tab)

  4. A zero-bias spark source for direct solid sample introduction for inductively coupled plasma atomic emission spectrometry

    … used as an ablation device for the analysis of solids with ICP-AES. Direct solid analysis has an inherent advantage for ICP applications as it allows a dry plasma to be maintained. This helps minimize the background species present as many arise from the water and acids present in solution. The …

    wayne-thes Repository record for A zero-bias spark source for direct solid sample introduction for inductively coupled plasma atomic emission spectrometry (opens in a new tab)

  5. Determination of the complex mass density of air contained in a rigid porous solid by an acoustic method

    … p(eff) of air contained in a rigid porous solid is investigated. An apparatus was designed and built which holds an air-filled porous solid sample within a cylindrical tube capped on each end by identical moving-coil loudspeakers. A quantity of air is made to oscillate back and forth as a …

    nps Repository record for Determination of the complex mass density of air contained in a rigid porous solid by an acoustic method (opens in a new tab)

  6. Ultrafast Temperature Jump Study of Energy Transfer in Dye-Doped Polymer Films

    Ultrafast laser spectroscopy of condensed matter samples containing dyes functioning as molecular optical heaters and optical thermometers is developed. A known amount of heat is deposited in a molecular solid sample and the temperature is accurately measured. This technique, termed ultrafast …

    uiuc Repository record for Ultrafast Temperature Jump Study of Energy Transfer in Dye-Doped Polymer Films (opens in a new tab)

  7. Phosphorescence of a Series of Substituted Aceto- and Benzophenones in Crystalline form at Room Temperature

    … spectra were obtained at room temperature from solid sample crystals formed on 2mm. soft glass rods. Lifetime data were gathered utilizing a rotating can shutter on the same samples, and where possible, lifetimes were calculated.

    creighton Repository record for Phosphorescence of a Series of Substituted Aceto- and Benzophenones in Crystalline form at Room Temperature (opens in a new tab)

  8. Synthesis of molecular nanocapsules for supramolecular host-guest chemistry and enzyme-like catalysis

    … manner at room temperature, by simply soaking a solid sample of the capsule in a fullerene containing solution. Strikingly, the larger nanocapsule is shown to be effective for the selective separation of C60 from a mixture of fullerenes using a straightforward washing protocol of a solid sample …

    barcelona Repository record for Synthesis of molecular nanocapsules for supramolecular host-guest chemistry and enzyme-like catalysis (opens in a new tab)

  9. Novel Strategies using Micro Pressurized Liquid Extraction to Rapidly Prepare Solid Samples for Analysis

    This thesis will describe several advancements in solid-liquid extraction methods using new applications of a micro preparative technique. The overall aim is to reduce solvent consumption and analysis times to promote quick, low solvent approaches to solid sample preparation. Additionally, this …

    calgary Repository record for Novel Strategies using Micro Pressurized Liquid Extraction to Rapidly Prepare Solid Samples for Analysis (opens in a new tab)

  10. Applications of Digital Microfluidics For The Quantification of Small Molecules from Solid Droplet-Scale Tissue Samples

    … nature, DMF is particularly promising for solid sample processing, enabling the incorporation of solid materials into the assay work-flow without risk of clogs. In this thesis, I explore the capabilities of DMF as a tool for processing microscale tissue samples that are otherwise difficult …

    toronto-retro Repository record for Applications of Digital Microfluidics For The Quantification of Small Molecules from Solid Droplet-Scale Tissue Samples (opens in a new tab)

  11. Downward flame front spread in thin solid fuels: theory and experiments

    Flame spread over solid samples has been studied from many points of view, as it is key for fire safety, yet it is a complex phenomenon that involves processes occurring in both the solid and the gas phases. This Ph.D. thesis studies the flame spread over thin solid samples in processes more …

    barcelona Repository record for Downward flame front spread in thin solid fuels: theory and experiments (opens in a new tab)

  12. Experimental observations and simulations of the mechanical deformation of amorphous metallic foam

    … exhibited any pressure sensitivity.</p> <p>The sample experiences uniform local deformation under compression until a few geometric instabilities in the foam induce local cell bending, followed by multiple shear band formation and localized fracture. Contrary to other reports that suggest …

    iastate Repository record for Experimental observations and simulations of the mechanical deformation of amorphous metallic foam (opens in a new tab)

  13. A liquid scintillation counter for low specific Beta activities

    … ways; as a volume counter and as a multiple-sample counter. In the first type of counter the solid radioactive sample is mixed with the liquid phosphor to form a transparent paste; in the second type a smaller amount of solid sample is spread out on a large surface of cellophane and immersed …

    ubc Repository record for A liquid scintillation counter for low specific Beta activities (opens in a new tab)

  14. Material Evaluation by Pulsed Diode Laser Optoacoustics

    … diagnostics were carried out to characterize solid sample materials. The apparatus developed is compact, portable, cost-effective and therefore very promising for both industrial as well as laboratory applications. To our knowledge, this is the first time that optoacoustic characterization and …

    odu Repository record for Material Evaluation by Pulsed Diode Laser Optoacoustics (opens in a new tab)

  15. A Novel Trace Elemental Analysis of Potassium Phosphates

    … can be a particularly difficult task due to the samples having a high dissolved solids content which can cause issues with ICP analyses. In this study, a method is developed to digest anhydrous tetrapotassium pyrophosphate and analyze for trace metals by inductively coupled plasma optical …

    ohiolink Repository record for A Novel Trace Elemental Analysis of Potassium Phosphates (opens in a new tab)

  16. Non-destructive moisture measurement using microwave-excited photoacoustics

    … could be used to analyze the moisture content of solid materials. The photoacoustic effect in both gaseous and nongaseous matter has been studied for a long time but most of the experiments were done by using optical energy. The idea of using microwave energy instead of optical energy is to get …

    iastate Repository record for Non-destructive moisture measurement using microwave-excited photoacoustics (opens in a new tab)

  17. Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS

    … be updated.In this work, method development of sample preparation and instrumental considerations were completed using oxygen mass-shift interference removal technology for the ICP-QQQ. An evaluation of internal standardization for SeO+ was completed using this instrument to determine if Se …

    ohiolink Repository record for Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS (opens in a new tab)

  18. Determination of Polar Solvents by Static Headspace Extraction – Gas Chromatography (SHE-GC)

    … the vapor that forms above or around a liquid or solid sample in a closed container. Usually, the vapor is above the liquid or solid at the top of the container, hence the term headspace. Headspace sampling is a method for separating volatile materials that may be extracted from a more solid …

    shu-thes Repository record for Determination of Polar Solvents by Static Headspace Extraction – Gas Chromatography (SHE-GC) (opens in a new tab)

  19. Laser-induced breakdown spectroscopy (LIBS), wavelength dispersive x-ray fluorescence (WDXRF) and chemometrics: possibilities for analytical applications in food analysis

    … The use of the LIBS and WDXRF allow the direct solid samples without or with a minimum sample treatment, high analytical frequency, lower reagent consumption, which become attractive when compared with conventional techniques. However, the disadvantage of the LIBS is its lower sensitivity, high …

    brazil-ufscar Repository record for Laser-induced breakdown spectroscopy (LIBS), wavelength dispersive x-ray fluorescence (WDXRF) and chemometrics: possibilities for analytical applications in food analysis (opens in a new tab)

  20. Studies and computing techniques in the spectral characterisation of solids

    … components, was fed (in a coaxial system) to a solid sample and the distorted output waveform could either be Fourier analysed by a computer whose output was programmed to give directly the variations of permittivity and dielectric loss with frequency or compared directly with reference …

    durham Repository record for Studies and computing techniques in the spectral characterisation of solids (opens in a new tab)

Page 1 of 4