Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 45 for “"Solid state detectors"”.

  1. DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS

    The latest experimental results of the multichannel front-end ASIC of TRACE are shown. The device submitted to the foundry in the middle of 2014 and received at the end of the same year has been installed on a dedicated PCB and tested using a pulser. We then designed and realized a preamplifier …

    milano Repository record for DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS (opens in a new tab)

  2. Fabrication process and characteristics of a silicon strip detector

    The current and possible uses of semiconductor solid state detectors in nuclear physics are briefly discussed. The theory of solid state detectors is discussed with emphasis on the silicon PIN diode detector. A fabrication process for silicon surface barrier position sensitive solid state detectors …

    ubc Repository record for Fabrication process and characteristics of a silicon strip detector (opens in a new tab) Download PDF for Fabrication process and characteristics of a silicon strip detector (opens in a new tab)

  3. Angular Correlations in Mg24

    … of coincidence experiments with Sodium Iodide detectors and angular distribution measurements with high resolution solid state detectors. The method is applied to the 8.87 MeV level in Mg24. </p>

    mcmaster Repository record for Angular Correlations in Mg24 (opens in a new tab)

  4. Gama Ray Spectroscopy Employing a Geranium Crystal Detector

    The Physics Department at South Dakota State University has recently been able to expand its facilities for beta and gamma ray spectroscopy. In the expansion two solid state detectors and a multichannel analyzer were acquired, along with a quantity of supporting electronics. In the first two …

    sdstate Repository record for Gama Ray Spectroscopy Employing a Geranium Crystal Detector (opens in a new tab)

  5. Fast Neutron Induced Fission of U238

    … energetics of the fission of U238 performed with solid state detectors. The fissions were produced by fission-spectrum neutrons from a reactor. The procedure used for calibrating the detector response is described and the effects of some experimental uncertainties, such as pulse height defect and …

    unm Repository record for Fast Neutron Induced Fission of U238 (opens in a new tab)

  6. Techniques and challenges in low-mass dark matter searches using CDMS style detectors

    … of galactic dark matter in sensitive detectors using a variety of technologies, including: cryogenic solid state detectors, time projection chambers with liquid noble elements, and bubble chambers with superheated fluids. The cryogenic operating temperatures of solid state detectors …

    queens Repository record for Techniques and challenges in low-mass dark matter searches using CDMS style detectors (opens in a new tab)

  7. Determination of the Optimal Gadolinium Thickness for Thermal Neutron Detection in (Almost) Isotropic Thermal Neutron Fields

    … for detecting thermal neutrons which is based on solid-state detectors on which thin layers of natural gadolinium (natGd) were deposited. The focus of this work lies on determining the optimal thickness of the gadolinium layer to detect thermal neutrons in a nearly isotropic neutron radiation …

    cau-kiel Repository record for Determination of the Optimal Gadolinium Thickness for Thermal Neutron Detection in (Almost) Isotropic Thermal Neutron Fields (opens in a new tab)

  8. The Boston Extended Amplitude Range (BEAR) IC for energetic particle detection

    Solid state detectors (SSD) are used in the direct detection of charged energetic particles and X-rays in different environments ranging from nuclear physics experiments and medical devices on Earth to, satellites in space. Solar energetic particles (SEP) originate at the Sun and are energized and …

    bu Repository record for The Boston Extended Amplitude Range (BEAR) IC for energetic particle detection (opens in a new tab)

  9. Infrared imaging - case studies and applications

    Recent advancements in the manufacture of solid state detectors have led to significant improvements in the use and applications of infrared (IR) imaging. Compared with traditional imaging in visible light, infrared imaging has abilities to convey significant additional information. Applications in …

    njit Repository record for Infrared imaging - case studies and applications (opens in a new tab)

  10. Helium-3 elastic, inelastic, and charge-exchange scattering from lithium-6 at 24.6 and 27.0 MeV

    … beam from the University of Illinois cyclotron. Solid state detectors in /\E - E' telescopes were used tc obtain energy spectra of the scattered 3He and of tritons from the charge exchange reaction. Differential cross sections were determined for elastic scattering inelastic scattering tD the …

    uiuc Repository record for Helium-3 elastic, inelastic, and charge-exchange scattering from lithium-6 at 24.6 and 27.0 MeV (opens in a new tab)

  11. Helium-3 inelastic scattering from several light nuclei

    … energy spectra were obtained through the use of solid state detectors in a LiE-E telescope. Data were taken at laboratory angles of 15° to 115°, in 5° intervals, and also in 2.5 0 intervals in some cases. Angular distributions were derived 9 for prominent levels corresponding to excitation …

    uiuc Repository record for Helium-3 inelastic scattering from several light nuclei (opens in a new tab)

  12. Isobaric analogue resonances in arsenic-75 (p,p) arsenic-75 and arsenic-75 (p,n) selenium-75 reactions

    … nucleus As . In the (p,p) measurements, three solid state detectors fixed at laboratory angles of 1°, 12°, and 15° were used to detect the elastically scattered protons, while in the (p,n) measurements both a conventional long counter and a specially designed 4TT counter were used. There is …

    rice Repository record for Isobaric analogue resonances in arsenic-75 (p,p) arsenic-75 and arsenic-75 (p,n) selenium-75 reactions (opens in a new tab)

  13. Direct-sequential order-of-emission interference effect

    … incident beam energies of 27.4 and 27.8 MeV. Two solid-state detectors were mounted in the reaction plane and set at such angles that the peak corresponding to the 9Be(3He,a)8Be(E . = excLt. 11.4 MeV) and the peak due to 8 Be(E .t = 11.4 MeV) -+ 2a, as eXCL. seen in a given detecto~ were …

    uiuc Repository record for Direct-sequential order-of-emission interference effect (opens in a new tab)

  14. A survey of low-noise nucleonic amplifiers

    … generalized to include systems using the modern solid-state detectors and amplifiers. Expressions are found relating the "equivalent input noise charge" to the characteristics of the detector, the preamplifier, and the pulse-shaping network. A relationship is derived between the equiv-noise …

    ubc Repository record for A survey of low-noise nucleonic amplifiers (opens in a new tab) Download PDF for A survey of low-noise nucleonic amplifiers (opens in a new tab)

  15. The scattering of protons by C__

    … volume gas scattering chamber was used with solid state detectors and a scintillation counter. Excitation functions for elastic and inelastic scattering at laboratory angles of 85.22°, 121.16°, and 159.45° in the range of bombarding energies 4.7 to 12.8 MeV and 6.o to 12.8 MeV, respectively, …

    rice Repository record for The scattering of protons by C__ (opens in a new tab)

  16. The scattering of protons by C¹²

    … volume gas scattering chamber was used with solid state detectors and a scintillation counter. Excitation functions for elastic and inelastic scattering at laboratory angles of 85.22°, 121.16°, and 159.45° in the range of bombarding energies 4.7 to 12.8 MeV and 6. to 12.8 MeV, respectively, …

    rice Repository record for The scattering of protons by C¹² (opens in a new tab)

  17. The elastic scattering of protons by He_

    … with SiO or Ni entrance foils and equipped with solid state detectors. and a scintillation counter for the experiment. Three excitation functions at center-of-mass angles of 900, 125° 18t, and 161° 12' have been measured from 4.5 to 10.4 MeV in steps of 200 keV. No sharp structure was observed. …

    rice Repository record for The elastic scattering of protons by He_ (opens in a new tab)

  18. Characterization of a Solid-State Detector for Dosimetry in the Diagnostic Energy Range with Verification via Monte Carlo Estimation of Average Breast Dose in Mammography

    … MBD methodology relies on detector design. Detectors must be thin for insertion between phantom layers. Therefore, MBD measurements were obtained using ionization chamber and two solid-state detectors (SSDs). One of the SSDs was modified to include backscatter. MBD metric was evaluated …

    vcu Repository record for Characterization of a Solid-State Detector for Dosimetry in the Diagnostic Energy Range with Verification via Monte Carlo Estimation of Average Breast Dose in Mammography (opens in a new tab)

Page 1 of 3