Use of solid state detectors to determine internal conversion coefficients
Electronic Thesis or Dissertation
-
DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS
The latest experimental results of the multichannel front-end ASIC of TRACE are shown. The device submitted to the foundry in the middle of 2014 and received at the end of the same year has been installed on a dedicated PCB and tested using a pulser. We then designed and realized a preamplifier …
-
Fabrication process and characteristics of a silicon strip detector
The current and possible uses of semiconductor solid state detectors in nuclear physics are briefly discussed. The theory of solid state detectors is discussed with emphasis on the silicon PIN diode detector. A fabrication process for silicon surface barrier position sensitive solid state detectors …
-
Angular Correlations in Mg24
… of coincidence experiments with Sodium Iodide detectors and angular distribution measurements with high resolution solid state detectors. The method is applied to the 8.87 MeV level in Mg24. </p>
-
Gama Ray Spectroscopy Employing a Geranium Crystal Detector
The Physics Department at South Dakota State University has recently been able to expand its facilities for beta and gamma ray spectroscopy. In the expansion two solid state detectors and a multichannel analyzer were acquired, along with a quantity of supporting electronics. In the first two …
-
Fast Neutron Induced Fission of U238
… energetics of the fission of U238 performed with solid state detectors. The fissions were produced by fission-spectrum neutrons from a reactor. The procedure used for calibrating the detector response is described and the effects of some experimental uncertainties, such as pulse height defect and …
-
Techniques and challenges in low-mass dark matter searches using CDMS style detectors
… of galactic dark matter in sensitive detectors using a variety of technologies, including: cryogenic solid state detectors, time projection chambers with liquid noble elements, and bubble chambers with superheated fluids. The cryogenic operating temperatures of solid state detectors …
-
Determination of the Optimal Gadolinium Thickness for Thermal Neutron Detection in (Almost) Isotropic Thermal Neutron Fields
… for detecting thermal neutrons which is based on solid-state detectors on which thin layers of natural gadolinium (natGd) were deposited. The focus of this work lies on determining the optimal thickness of the gadolinium layer to detect thermal neutrons in a nearly isotropic neutron radiation …
-
The Boston Extended Amplitude Range (BEAR) IC for energetic particle detection
Solid state detectors (SSD) are used in the direct detection of charged energetic particles and X-rays in different environments ranging from nuclear physics experiments and medical devices on Earth to, satellites in space. Solar energetic particles (SEP) originate at the Sun and are energized and …
-
Infrared imaging - case studies and applications
Recent advancements in the manufacture of solid state detectors have led to significant improvements in the use and applications of infrared (IR) imaging. Compared with traditional imaging in visible light, infrared imaging has abilities to convey significant additional information. Applications in …
-
Helium-3 elastic, inelastic, and charge-exchange scattering from lithium-6 at 24.6 and 27.0 MeV
… beam from the University of Illinois cyclotron. Solid state detectors in /\E - E' telescopes were used tc obtain energy spectra of the scattered 3He and of tritons from the charge exchange reaction. Differential cross sections were determined for elastic scattering inelastic scattering tD the …
-
Helium-3 inelastic scattering from several light nuclei
… energy spectra were obtained through the use of solid state detectors in a LiE-E telescope. Data were taken at laboratory angles of 15° to 115°, in 5° intervals, and also in 2.5 0 intervals in some cases. Angular distributions were derived 9 for prominent levels corresponding to excitation …
-
Isobaric analogue resonances in arsenic-75 (p,p) arsenic-75 and arsenic-75 (p,n) selenium-75 reactions
… nucleus As . In the (p,p) measurements, three solid state detectors fixed at laboratory angles of 1°, 12°, and 15° were used to detect the elastically scattered protons, while in the (p,n) measurements both a conventional long counter and a specially designed 4TT counter were used. There is …
-
Direct-sequential order-of-emission interference effect
… incident beam energies of 27.4 and 27.8 MeV. Two solid-state detectors were mounted in the reaction plane and set at such angles that the peak corresponding to the 9Be(3He,a)8Be(E . = excLt. 11.4 MeV) and the peak due to 8 Be(E .t = 11.4 MeV) -+ 2a, as eXCL. seen in a given detecto~ were …
-
A survey of low-noise nucleonic amplifiers
… generalized to include systems using the modern solid-state detectors and amplifiers. Expressions are found relating the "equivalent input noise charge" to the characteristics of the detector, the preamplifier, and the pulse-shaping network. A relationship is derived between the equiv-noise …
-
The scattering of protons by C__
… volume gas scattering chamber was used with solid state detectors and a scintillation counter. Excitation functions for elastic and inelastic scattering at laboratory angles of 85.22°, 121.16°, and 159.45° in the range of bombarding energies 4.7 to 12.8 MeV and 6.o to 12.8 MeV, respectively, …
-
The scattering of protons by C¹²
… volume gas scattering chamber was used with solid state detectors and a scintillation counter. Excitation functions for elastic and inelastic scattering at laboratory angles of 85.22°, 121.16°, and 159.45° in the range of bombarding energies 4.7 to 12.8 MeV and 6. to 12.8 MeV, respectively, …
-
The elastic scattering of protons by He_
… with SiO or Ni entrance foils and equipped with solid state detectors. and a scintillation counter for the experiment. Three excitation functions at center-of-mass angles of 900, 125° 18t, and 161° 12' have been measured from 4.5 to 10.4 MeV in steps of 200 keV. No sharp structure was observed. …
-
Characterization of a Solid-State Detector for Dosimetry in the Diagnostic Energy Range with Verification via Monte Carlo Estimation of Average Breast Dose in Mammography
… MBD methodology relies on detector design. Detectors must be thin for insertion between phantom layers. Therefore, MBD measurements were obtained using ionization chamber and two solid-state detectors (SSDs). One of the SSDs was modified to include backscatter. MBD metric was evaluated …