Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"Solid-State Detector"”.
-
A solid state detector head for astronomical applications
A detector head for housing self scanned silicon photo-detector arrays has been constructed for use in astronomy. It employs a unique frozen methanol cooling-"system and, although built specifically for the linear Reticon devices, it is capable of housing other linear or two dimensional monolithic …
-
Comparison of Peak Skin Dose Calculated by Patient Radiation Dose Monitoring and Tracking Systems versus Solid-State Detector Measurements
… between the PSD measured and calculated from a solid-state detector and the values the unit is displaying. Also, the study will compare PSD measurements from Patient Radiation Dose Monitoring and Tracking Systems (PRDMT). Numerous parameters need to be obtained to depict the PSD that a patient …
-
Characterization of a Solid-State Detector for Dosimetry in the Diagnostic Energy Range with Verification via Monte Carlo Estimation of Average Breast Dose in Mammography
… Carlo simulation. MBD methodology relies on detector design. Detectors must be thin for insertion between phantom layers. Therefore, MBD measurements were obtained using ionization chamber and two solid-state detectors (SSDs). One of the SSDs was modified to include backscatter. MBD metric …
-
He3-induced reactions in Li6 and Li7
… by He3 particles at 21.2, 24.5, and 26.8 MeV. A solid-state-detector telescope detected He3 and et particles, plus some tritons, coming from the target. The forms of the angular distributions were characteristie of direct interaction processes. ... Each reaction is discussed, and the angular …
-
The preparation of a monoenergetic neutron beam with energy between 8-14 MeV
… were detected using a very thin scintillation detector and the time of flight technique. The high cross section of the D(d,n)He3 reaction at forward angles was utilized: and the shape of the neutron beam was determined. The results were compared to those obtained width a solid state detector. …
-
A study of a multi-wire proportional counter for magnetic spectrograph focal plane detection
… to results obtained with a position-sensitive solid state detector. The MWPC was thus found to be at least 98% efficient in the detection of 6 MeV protons. The spatial resolution of about 3 mm was limited by the multiple scattering of the protons in the counter foils and gas.
-
The H_(p,pn)p reaction using coincidence and time-of-flight techniques
… proton energy was measured in a surface barrier, solid state detector. The neutron energy was determined by its time-offlight, using the delayed proton pulse as a stop pulse for the Time to Pulse Height Converter. The TPH Converter pulse and proton pulse were then observed in slow coincidence with …
-
The Development of a Medium Energy Ion Reflection Spectrometer and Some Problems Associated with its Application to Materials Analysis
… specific application to near surface analysis of solids. The work is divided into two parts.</p> <p>Part I details the design, operation and calibration of the systems within the spectrometer. They include a high resolution electrostatic analyzer and a premium solid state detector cooled to …
-
Search for fractionally charged particles in terrestrial samples
… the negatively charged particles to a solid state detector. The pulse height spectra from the detector were scanned for peaks corresponding to particles of a charge between minus one and zero. No such particles were found. The concentration of ql quarks in the rock samples was < 10^-23 …
-
Unipolar Charge-Sensing for Evaporated Large-Area Solid-State Photoconductors for Digital Radiography
… In most applications, however, the use of a solid detection medium is preferable because solid densities are about three orders-of-magnitude greater than gas, and thus, they can yield much smaller detector dimensions with unsurpassed spatial and temporal resolution. Thus far, crystalline …
-
Monte Carlo investigations of radiotherapy beams: studies of conventional, stereotactic and unflattened beams
… aimed to investigate the performance of the DOSI detector, a prototype detector which is position sensitive with submillimeter resolution. This solid-state detector is made of p-type diode has silicon material as its volume element. Work from other authors has shown that other silicon detectors …
-
DIGITAL HETERODYNE TOPOGRAPHY (MOIRE, CONTOURING, PROFILOMETRY).
… technique. A method of sampling the image with a solid state detector array which produces a moire fringe image free of the noise terms normally present with moire techniques is presented along with an extension to Whittaker-Shannon sampling theory to cover the moire aliasing phenomena. The …
-
Studies in the Behaviour of Molecular Beams
… for the study of interactions of gases with solid surfaces in systems of catalytic interest. The apparatus has been used in an investigation of the displacement, from palladium surfaces, of the surface species resulting from the adsorption of ethylene C-14 by beams of acetylene and ethylene. …
-
Positron annihilation in the alkali halides
… system for the lifetime spectra and a Ge(Li) detector to measure the doppler broadening of the.511 Mev. annihilation line. An attempt is made to correlate the results of the high pressure work on NaCl with the behavior of vacancies within the context of the A-center model. From this work an …
-
Proton Removal Spectroscopy in TexAT
… removal spectroscopic factors to low-lying states in 12Be was attempted. The reaction of interest was 13^B(d,^3He)^12Be performed in inverse kinematics. Using the Momentum Achromat Recoil Spectrometer (MARS) at the Texas A&M University Cyclotron Institute (TAMU-CI), a 13B beam was delivered …
-
Nuclear charge distribution of ¹⁸¹Ta
… muonic atom of 181Ta were measured by a Ge(Li) solid state detector. From the clustering of these gamma rays it was possible to identify the transitions of the muonic atom which produced them. When a form is chosen for the nuclear charge distribution, a theoretical spectrum can be calculated…The …
-
Simulação Monte Carlo de mamógrafos para determinação da Dose Glandular Média, para diferentes combinações anodo/filtro dos tubos de Raios-X
… using the following equipment: a mammograph; a solid state detector; a spectrometer (for spectra only); a clinical COMET X-ray tube; and the MCNPX Code. The references recommend, in the DR, the following X-ray tube voltages: 25 kVp; 26 kVp; 28 kVp; 31 kVp and 33 kVp. For the CR system: 26 kVp; …
-
Fabrication and Characterization of Thin Films for Heterojunction Solar Cells and Radiation Detectors
… amorphous selenium alloy film, a new solid-state detector material for neutron detection. In this study CZTS thin film was developed by employing low-cost, high- throughput spray pyrolysis technique, followed by sulfurization under a 5% H2S flow at 550°C. Characterization of deposited …