Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 72 for “"Source reconstruction"”
-
Time-varying source reconstruction
… (and noise) covariance. To date, the majority of source localisation algorithms employ static approximations to the data covariance matrix.</p> <p>Here we make the argument that researchers should consider a Temporally Adaptive SourcE Reconstruction (TASER) approach to solving the inverse problem. …
-
Spatial-temporal Source Reconstruction for Magnetoencephalography
… for MEG spatial-temporal current course reconstruction by introducing classical methods from the pattern recognition theory into medical imaging. These applications provide a new angle for research in MEG source reconstruction with the solution for source reconstruction at a single point, …
-
Acoustical source reconstruction from non-synchronous sequential measurements
… ces données restent nécessaires pour la reconstruction acoustique. Dans l'approche classique, une ou plusieurs références sont utilisées pour retrouver les données manquantes. L'objet de cette thèse est de récupérer les éléments manquants de la matrice interspectrale sans capteurs de …
-
Source reconstruction in near field scanning for RFI application
… discussed in the first paper. The second topic, source reconstruction in near field scanning for RFI application, is discussed over the course of two papers. The third topic, analysis of imbalanced 2 or 3 Wire VHF LISN, is discussed in the last two papers. In the first topic, the possibility to …
-
The use of the source reconstruction method for antenna characterization
This thesis studies the use of the Source Reconstruction Method (SRM) to characterize antennas. The SRM calculates equivalent sources/currents on an arbitrarily shaped reconstruction surface to represent the original antenna. This is done by enforcing that the original antenna and equivalent …
-
Radome Diagnostics: utilizing Source Reconstruction based on Surface Integral Representations
In this thesis, an inverse source reconstruction method with great potential in radome diagnostics is presented. A radome is a cover that encloses an antenna in order to protect it from environmental influences. Radome diagnostics are acquired in the design process, the delivery control, and in …
-
Improved Source-Reconstruction Through the Exploitation of Dose-Response Models
… by it on human health. Characterizing the source of an atmospheric contaminant is typically regarded as an inverse problem, where one has to infer the source characteristics of the released HazMat from concentration or deposition measurements. The inverse solution is obtained by combining …
-
Advanced Source Reconstruction and Volume Conductor Modeling for Fetal Magnetocardiography
… from the maternal abdomen are affected by the source-to-sensor distance as well as by the geometry of the volume conductor, which is variable in different subjects or in the same subject when recordings are made at different gestational ages. The scope of this thesis is to develop a novel …
-
Influence of atlas-based and patient dependent forward models in EEG source reconstruction
Electroencephalography Source Imaging (ESI) techniques have become the most attractive alternative to support the estimation of neuronal activity through the mapping of electrical potentials measured over the scalp. It takes advantage of the low implementation cost, the high temporal resolution, …
-
Neutron Source Reconstruction from One-Dimensional Imager of Neutrons at the Z Facility
… based solid state nuclear track detectors. Image reconstruction methods have the ability to perform an inverse problem and produce an axial neutron emission profile, which to date has never been performed with this diagnostic. Here, an analytical forward model of the one-dimensional imager of …
-
RECIPROCITY-BASED TRANSFER FUNCTION TECHNIQUES FOR ACOUSTIC SOURCE RECONSTRUCTION, SPRING ISOLATOR CHARACTERIZATION AND STRUCTURAL DAMPING ASSESSMENT
… that a system responds identically when the source and receiver positions are interchanged. This dissertation applies this principle to address three practical challenges in noise and vibration characterization, where conventional approaches are limited by inaccessible interfaces, constrained …
-
Performance comparison of functional and effective brain connectivity methods
… during the simulation, preprocessing or inverse source reconstruction of realistic EEG recordings. A decisive advantage of this simulation framework, when compared with models utilised in other studies, is the integration of volume conduction artifacts. This is achieved by modelling the …
-
Performance comparison of functional and effective brain connectivity methods
… during the simulation, preprocessing or inverse source reconstruction of realistic EEG recordings. A decisive advantage of this simulation framework, when compared with models utilised in other studies, is the integration of volume conduction artifacts. This is achieved by modelling the …
-
Antenna characterization using phaseless near-field antenna measurements
… on the application of electromagnetic inverse source techniques to characterize antennas using phaseless (amplitude-only) near-field (NF) measurement data. Removing the need to measure phase reduces the overall cost of the measurement apparatus since simple power meters can be used instead of …
-
Wavefield reconstruction using seismic interferometry and compressive sensing
… apply to seismic interferometry, a passive-source technique to estimate inter-receiver wavefields. In this thesis, I propose novel methods that use seismic interferometry and compressive sensing to mitigate these problems. I use inter-source interferometry to estimate body waves that …
-
Algorithms and Numerical Methods for Electrical Brain Imaging
… system, as in electroencephalographic (EEG) source reconstruction, or make use of external current injections, as in electrical impedance tomography (EIT) , to image the structure or function of the brain. When compared to other brain imaging methods used in research or in the clinical …
-
Localisation and time courses of CMV generators from MFT analysis of average MEG signals
… the accuracy of typical MEG systems before any source reconstruction is applied. The second and main part is concerned with localisation and time courses of neuronal generators contributing to both the slow and fast neuromagnedc field changes associated with the contingent negative variation …
-
Compressed Sensing in the Presence of Side Information
Reconstruction of continuous signals from a number of their discrete samples is central to digital signal processing. Digital devices can only process discrete data and thus processing the continuous signals requires discretization. After discretization, possibility of unique reconstruction of the …
Page 1 of 4