Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 226 for “"SpO2"”.
-
Predicción del índice PaO2/FiO2 a partir del índice SpO2/FiO2 en niños
… [Saturación pulsioximétrica de la hemoglobina (SpO2)/FiO2] se correlaciona con el índice P/F y puede ser útil en la valoración no invasiva de la oxigenación en el niño críticamente enfermo. Se analizaron los datos simultáneos de SpO2, FiO2 y PaO2 en una muestra de niños admitidos en una unidad …
-
Estimation of SpO2 levels and heart rate from ppg signals in the presence of motion artifacts
<p>In the rapidly advancing world of health technology, wearable devices are at the forefront, fundamentally changing how individuals monitor their health. The key to this transformation is photoplethysmography (PPG), a non-invasive optical method that measures blood flow variations through the …
-
The revised digital transcutaneous PCO2/SpO2 Ear Sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery
OBJECTIVE: The aim of this study was to validate the revised SenTec V-Sign 2 sensor (SenTec AG, Therwil, Switzerland) for combined noninvasive continuous assessment of pulse rate, pulse oximetry (SpO(2)), and transcutaneous carbon dioxide tension (PtcCO(2)) in adults after cardiac surgery. DESIGN: …
-
Predicting the Clinical Actionability of SpO2 Alarms in Intensive Care Medicine: Development of Explainable Machine Learning Models on Multimodal Clinical Data
… actionability of peripheral oxygen saturation (SpO2) alarms using multimodal clinical data, and 2) provide detailed insights into the relationship between clinical data and the model’s predictions. Methods: A retrospective cohort study was conducted using an annotated dataset collected from …
-
Estudo do comportamento da saturação periférica de oxigênio durante o teste de caminhada de 6 minutos em pacientes com doenças pulmonares crônicas
… da monitorização contínua da oximetria de pulso (SpO2) durante o teste de caminhada de 6 minutos (TC6m), na detecção da hipoxemia induzida pelo exercício, em pacientes com sintomas respiratórios. Métodos: Os pacientes realizaram testes de função pulmonar e TC6m. A saturação e a freqüência cardíaca …
-
Mortalidad en pacientes con infección respiratoria aguda por SARS-CoV-2 según índice de oxigenación SpO2/FiO2 y valores hematométricos de ingreso a 2500 m s.n.m.
… history, and no lineal relations of the SpO2/FiO2, hemoglobin and neutrophil/lymphocytes relation were reported whit the mortality of the patients with ARI due to SARS-CoV2 admitted to HUM between March and July of 2020. In addition, the groups with the patients with higher and lower …
-
Διαταραχές της οξυγόνωσης στη διάρκεια της νύχτας σε βρέφη και παιδιά: σύγκριση απόφραξης ανώτερου αεραγωγού και οξείας ή χρόνιας νόσου των πνευμόνων
… (i) oxygen desaturation of hemoglobin index (SpO2 drops ≥3%/h-ODI3) and (ii) basal SpO2 (average SpO2 between SpO2 drops). (B) We analyzed oximetry recordings from children with: (i) obstructive lung disease (i.e. obliterative bronchiolitis or cystic fibrosis); (ii) snoring and adenotonsillar …
-
Modeling and control of arterial oxygen saturation in premature infants
… of neonatal infant's blood oxygen saturation (SpO2) is investigated. Through analyzing the biological system, it was shown that the blood is oxygenated through the mechanisms of ventilation, perfusion, and diffusion. It was also shown that the fraction of inspired oxygen (FiO2), heart rate, and …
-
Importância da monitorização contínua da oximetria de pulso durante o teste de caminhada dos seis minutos sobre a predição de mortalidade e internações hospitalares em pacientes com doença pulmonar obstrutiva crônica
… a monitorização contínua da oximetria de pulso (SpO2) durante sua realização. Sugere-se que a menor SpO2 observada durante o teste (nadir) seria melhor preditora de desfechos clínicos relevantes em comparação à avaliação da SpO2 ao final do teste sem, no entanto, haver demonstração inequívoca de …
-
Exploration of cord acid-base and glucose status of term and near-term infants, and oxygenation in preterm infants, with regard to mortality and clinically significant outcome
… (PaO2) and pulse oximeter oxygen saturations (SpO2), and then via case control studies examines the influence of oxygenation on important clinical outcomes (mortality and retinopathy of prematurity (ROP)). Acid-base status of term and near-term infants and likelihood of death and cerebral palsy …
-
Feed-Forward Regulation of Self-Selected Exercise Intensity in Response to Different Rates of Arterial Deoxygenation
… alterations in the absolute arterial saturation (SPO2) and/or the rate of change in SPO2. Methods: Subjects performed constant RPE exercise for 30 min. They were instructed to adjust their exercise intensity during the trial to maintain their RPE at 5 on Borg’s 10-point scale. Subjects engaged in …
-
Polynomial system identification modeling and adaptive model predictive control of arterial oxygen saturation in premature infants
… maintaining arterial oxygen saturation levels (SpO2) while simultaneously not inducing complications such as retrolental fibroplasia. Historically, models of the dynamics of the neonatal respiratory system were first order transfer function approximations. This work used higher order polynomial …
-
Investigation of the performance of an automatic arterial oxygen controller
… (FiO2) to keep the arterial oxygen saturation (SpO2) within the desired range to avoid both hypoxemia and hyperoxemia. Currently, manual adjustment of FiO2 is the common practice in neonatal intensive care units (NICUs). The automation of this adjustment is a topic of interest. The research …
-
The Association Between Sleep Disturbance and the Neurocognitive Function in Pediatric Sickle Cell Disease
… that the mean nocturnal oxygen saturation (SpO2) significantly predicted verbal comprehension above and beyond demographic and SES factors. Specifically, verbal comprehension decreased by 2.37 standard points for every unit decrease in mean SpO2 (p=0.031). Working memory was also found to …
-
In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion
… (PPG) to estimate arterial oxygen saturation (SpO2). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often small and noisy, or in some cases unobtainable. Hence, pulse oximeters produce erroneous SpO2 readings in …
-
Utilidad de las señales de oximetría y flujo aéreo en el diagnóstico simplificado de la apnea obstructiva del sueño. Diseño de un test automático domiciliario
… of machine learning algorithms of unsupervised SpO2 and AF signals acquired at patient's home leads to a significant increase in diagnostic performance compared to single-channel approaches. A prospective observational study was carried out in which a population referred consecutively to the …
-
Impacto da monitorização contínua da oximetria de pulso sobre a distância percorrida no teste de caminhada de seis minutos em pacientes com doenças respiratórias crônicas
… a monitorização contínua da oximetria de pulso (SpO2) durante o teste e a interrupção pelo examinador na presença de dessaturação grave induzida pelo exercício (SpO2<80%). A monitorização contínua da SpO2 pode ocasionar a interrupção do TC6min pelo examinador ao verificar valores críticos de tal …
-
THE EFFECT OF BODY POSITION CHANGES ON ARTERIAL OXYGEN SATURATION IN OBESITY AS MEASURED NONINVASIVELY BY PULSE OXIMETRY
… was measured by a Nelcor® N-100 pulse oximeter (SpO2). Subjects were then placed supine on a stretcher for 10 minutes. Pulse oximetry values were recorded immediately following position change and then serially for 10 minutes. Macro analysis of the means across all measurements between both …
-
Incidence of hypoxaemia with intravenous fentanyl and midazolam sedation in adult patients undergoing oral surgery procedures
… was to investigate the incidence of hypoxaemia (SpO2 ≤94%) in American Society of Anaesthesiologists physical status I & II patients undergoing intravenous sedation with fentanyl and midazolam. The secondary aims included determination of the onset time of hypoxaemic events and significant risk …
Page 1 of 12