Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 55 for “"Sparger"”.

  1. Investigating the Effects of Sparger Design in Column Photobioreactors

    … photobioreactors (PBRs) are changed based on the sparger types, spacings, and positions. Computational Fluid Dynamics (CFD) is used to predict fluid flow patterns, thermal profiles and additional hydrodynamic and heat transfer parameters in these photobioreactors. The gas bubbles and the …

    sdstate Repository record for Investigating the Effects of Sparger Design in Column Photobioreactors (opens in a new tab)

  2. Sparger design as a critical component of a military field-deployable autotransfusion system

    … inducing haemolysis. A hemispherically-shaped sparger mechanism was developed over multiple design iterations to slow and radially disperse the flow. Hoods were used to hold the vertically hanging sock away from the sparger and assist in directing flow. Following a series of design …

    strathclyde Repository record for Sparger design as a critical component of a military field-deployable autotransfusion system (opens in a new tab)

  3. Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger

    … Homogenous and Heterogenous flows. Two different spargers (point sparger and four arm spargers) were used to study the effect of the sparger design on the hydrodynamics. The measurement uncertainty of the WMS and PTs for air-water two-phase flows is investigated by repeating the experiments. The …

    cuny Repository record for Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger (opens in a new tab)

  4. Designing and Development of a Photobioreactor for Optimizing the Growth of Micro Algae and Studying Its Growth Parameters

    … and flow rate. This thesis aims to design the sparger for a flat plate Photobioreactor, study the flow patterns at different flow rate of air flow and check the performance of flat plate PBR by growing the cyanobacteria. The estimated value to produce 1g of biomass (C44.6H7O25N7.68P0.9S0.3) was …

    sdstate Repository record for Designing and Development of a Photobioreactor for Optimizing the Growth of Micro Algae and Studying Its Growth Parameters (opens in a new tab)

  5. Development of a Novel Air Sparging Device

    … air sparging technologies. High performance air spargers increase the probability of collision and attachment between air bubbles and particles, thereby improving recovery of fine and coarse mineral particles otherwise misplaced to the tailings fraction in conventional flotation cells. Although …

    vt Repository record for Development of a Novel Air Sparging Device (opens in a new tab)

  6. Effects Of Different Aeration Conditions On Isochrysis Galbana (T-Iso) Ccmp 1324 In A Bench-Scale Photobioreactor

    … created using a 1.6 mm diameter syringe. Four sparger diameters were used to test the effects of sparger velocities that ranged from 2.48 to 73.4 m s-1. The effect of bubble size was evaluated by using two styles of air stones and an open glass pipet, which created a bubble size range of 0.5 to …

    cornell Repository record for Effects Of Different Aeration Conditions On Isochrysis Galbana (T-Iso) Ccmp 1324 In A Bench-Scale Photobioreactor (opens in a new tab)

  7. Experimental Investigation of Reactor Core Isolation Cooling System Exhaust Design in Boiling Water Reactor Suppression Pools and Reactor Safety Implications

    … the suppression chamber. The vertical perforated sparger class of RCIC exhaust was tested for its effect on thermal stratification in the suppression pool for comparison with the vertical open-ended pipe class of design. These results are important for RCIC System operation. One RCIC exhaust line …

    tamu Repository record for Experimental Investigation of Reactor Core Isolation Cooling System Exhaust Design in Boiling Water Reactor Suppression Pools and Reactor Safety Implications (opens in a new tab)

  8. Mixing in anaerobic digesters

    … of the active volume expected with different gas sparger types and the blend times expected within this active volume.</p> <p>Due to a greater sludge production and restrictions enforced on disposal routes, many sludge producers want to increase the available sludge digestion capacity using their …

    soton Download PDF for Mixing in anaerobic digesters (opens in a new tab)

  9. Μελέτη στήλης φυσαλίδων με πορώδη κατανομέα της αέριας φάσης

    … of bubble columns equipped with porous plate sparger. The scope of this thesis is to study the operation of a bubble column with porous gas sparger by conducting experiments both in macroscopic and microscopic scale. The effect of the liquid phase properties, the addition of surfactants in the …

    greece Repository record for Μελέτη στήλης φυσαλίδων με πορώδη κατανομέα της αέριας φάσης (opens in a new tab)

  10. Distributed Acoustic Sensing for Active Monitoring of a Carbfix CO2 Injection Well

    … signal increases near and below the interpreted sparger interval. These responses were strong enough to support preliminary gas-state classification and post-sparger signal tracking. While the DAS data do not directly measure bubble dissolution or gas fraction, they demonstrate that low-frequency …

    reykjavik Repository record for Distributed Acoustic Sensing for Active Monitoring of a Carbfix CO2 Injection Well (opens in a new tab)

  11. Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers

    … Homogenous and Heterogenous flows. Two different spargers (point sparger and four arm spargers) were used to study the effect of the sparger design on the hydrodynamics. The measurement uncertainty of the WMS and PTs for air-water two-phase flows is investigated by repeating the experiments. The …

    cuny Repository record for Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers (opens in a new tab)

  12. Estudo experimental e modelagem matemática do processo de produção de biodiesel em reator de borbulhamento

    … flow rate, reaction temperature and usage of gas sparger were evaluated based on free fatty acid conversion. The results showed that all variables evaluated presented strong effect on bubble reactor performance, where 98% conversion was achieved at reaction temperature of 130°C and volumetric …

    brazil-ufrn Repository record for Estudo experimental e modelagem matemática do processo de produção de biodiesel em reator de borbulhamento (opens in a new tab)

  13. Comparative Studies on Oxygen Mass Transfer for the Design and Development of a Single-Use Fermentor

    … impeller, is optimal for oxygen mass transfer. Sparger type was shown to have little effect on oxygen mass transfer values, although an open-pipe sparger was shown to provide slightly more oxygen mass transfer than a ring sparger. The use of rounded baffles in place of traditional rectangular …

    utahstate Repository record for Comparative Studies on Oxygen Mass Transfer for the Design and Development of a Single-Use Fermentor (opens in a new tab)

  14. Multiphase CFD Analysis of Direct Contact Condensation Flow Regimes in a Large Water Pool

    … exceeding the inlet steam mass flow rate to the Sparger of 45 g/s. The formation of a hot spot near the Suppression Chamber Sparger outlet likely caused this flow regime to be observed experimentally. This led to the conclusion that better spatial resolution of the water temperature obtained from …

    tamu Repository record for Multiphase CFD Analysis of Direct Contact Condensation Flow Regimes in a Large Water Pool (opens in a new tab)

  15. Characterization and Improvement of Oxygen Mass Transfer in a Rocking Disposable Bioreactor

    … Secondly, a submerged sintered polyethylene tube sparger was installed into the bioreactor to improve its oxygen gas-liquid mass transfer capacity. The gas flow condition and sparger surface wettability were changed to study the impact of these variables on the sparger performance. The results …

    waterloo Repository record for Characterization and Improvement of Oxygen Mass Transfer in a Rocking Disposable Bioreactor (opens in a new tab)

  16. Analysis of ejector-style microbubble generators : mass-transfer properties, mathematical modeling, and design algorithm

    … microbubble ejector and a conventional ring sparger. E. coli batch growth experiments were conducted to compare the growth rates using the two aeration methods. The E. coli growth rate observed during microbubble aeration was about twice that observed with the traditional ring sparger. …

    msu Repository record for Analysis of ejector-style microbubble generators : mass-transfer properties, mathematical modeling, and design algorithm (opens in a new tab)

  17. Effect of flotation frothers on bubble size and foam stability

    … determined by coalescence but depends on the sparger geometry and hydrodynamic conditions. The efficiency of different spargers can thus be compared only when the experiments are carried out at frother concentrations exceeding CCC. Flotation experiments carried out using small-scale flotation …

    ubc Repository record for Effect of flotation frothers on bubble size and foam stability (opens in a new tab) Download PDF for Effect of flotation frothers on bubble size and foam stability (opens in a new tab)

  18. Mass-transfer correlations for the dual bed colloidal suspension reactor

    … given. An analysis of the orientation of the gas sparger suggests that the transport phenomena in both cells is not the same, and therefore using two correlations to represent similar systems is justified. An energy analysis is presented that shows that gas sparging is a low energy consumption …

    gatech Repository record for Mass-transfer correlations for the dual bed colloidal suspension reactor (opens in a new tab)

Page 1 of 3