Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 97 for “"Specific Absorption Rate (SAR)."”.

  1. SMALL SIZE COUPLING FEED AND INDUCTIVE SHORTING ANTENNA FOR WIDE BANDWIDTH, INCREASED GAIN AND EFFICIENCY WITH LOW SPECIFIC ABSORPTION RATE (SAR) OPERATION

    … Modern cellular phone should be capable to operate in wide range of frequency spectrum for their global access to provide end user customers these communication services. Hence mobile antennas should be designed in such a way that they should generate wideband operation. But commercially …

    mtu Repository record for SMALL SIZE COUPLING FEED AND INDUCTIVE SHORTING ANTENNA FOR WIDE BANDWIDTH, INCREASED GAIN AND EFFICIENCY WITH LOW SPECIFIC ABSORPTION RATE (SAR) OPERATION (opens in a new tab)

  2. MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATIONS

    … magnetic resonance imaging (MRI) contrast and specific absorption rate (SAR) properties. In vitro experiments have demonstrated high cellular uptake and low cytotoxicity and the AC magnetic field heating experiments showed effectiveness in temperature rise and 60-74% cancer cell death due to …

    nus Repository record for MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATIONS (opens in a new tab) Download file for MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATIONS (opens in a new tab)

  3. Analysis of wireless power transfer efficiency and specific absorption rate for a distributed brain implant system.

    … power transfer (WPT) efficiency and reducing the specific absorption rate (SAR) will be crucial for its clinical success. Towards these goals, we present an EM simulation method, a lumped equivalent circuit model, and a theoretical analysis to accurately predict the power delivered to the …

    baylor Repository record for Analysis of wireless power transfer efficiency and specific absorption rate for a distributed brain implant system. (opens in a new tab)

  4. Radio frequency power absorption in a human model with pacemakers in MRI

    … with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker …

    uvic Repository record for Radio frequency power absorption in a human model with pacemakers in MRI (opens in a new tab)

  5. Orientation-dependent adaptive antenna for low earth orbit satellite communications

    … power makes it difficult for the device to meet specific absorption rate (SAR) restrictions. An adaptive beam forming technique for shaping radiation away from the user’s head is proposed. This technique uses a back-to-back patch antenna design with an impedance monitoring based system capable of …

    manitoba Repository record for Orientation-dependent adaptive antenna for low earth orbit satellite communications (opens in a new tab)

  6. Variable Rate Selective Excitation RF Pulse in MRI

    … Radio Frequency (RF) pulses. A Variable Rate Selective Excitation (VERSE) pulse is a type of RF pulse that reduces the Specific Absorption Rate (SAR) of molecules in a specimen while preserving its duration and slice profile. SAR was designed to be minimized by the VERSE pulse as it leads …

    mcmaster Repository record for Variable Rate Selective Excitation RF Pulse in MRI (opens in a new tab)

  7. Precise SAR Measurements In The Near-Field of RF Antenna Systems

    Wireless devices must meet specific safety radiation limits, and in order to assess the health affects of such devices, standard procedures are used in which standard phantoms, tissue-equivalent liquids, and miniature electric field probes are used. The accuracy of such measurements depend on the …

    maryland Repository record for Precise SAR Measurements In The Near-Field of RF Antenna Systems (opens in a new tab)

  8. Uncertainty in computational RF dosimetry

    … (RF) electromagnetic field dosimetry studies the absorption of electromagnetic energy inside the human body. The absorbed energy is measured in terms of the specific absorption rate (SAR), which is linked to the possible adverse thermal effects of the exposure to RF electromagnetic fields. With …

    aalto Repository record for Uncertainty in computational RF dosimetry (opens in a new tab)

  9. Redução de taxa de absorção específica em phantoms de tecidos humanos por meio de superfícies seletivas em frequência com substratos feitos de têxteis hospitalares

    This work proposes an integrated antenna with frequency selective surface (FSS) with textile substrate for applications in medical continuous monitoring systems with reduced specific absorption rate (SAR). The antenna and FSS were fabricated on cotton and polyester textile substrates, used in …

    brazil-ufrn Repository record for Redução de taxa de absorção específica em phantoms de tecidos humanos por meio de superfícies seletivas em frequência com substratos feitos de têxteis hospitalares (opens in a new tab)

  10. Modeling and calculation of the specific absorption rate for multi-antenna mobile devices

    … the human exposure to the RF radiation, the specific absorption rate (SAR) is introduced as a measure. Regulatory agencies have standards limiting the maximum SAR to ensure safety. In order to comply with the regulations, the SAR induced in the human head and body should be evaluated by …

    uiuc Repository record for Modeling and calculation of the specific absorption rate for multi-antenna mobile devices (opens in a new tab)

  11. Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants

    … concerns constrain the implanted sensors to operate without any transcutaneous wire connection which raises serious challenges for powering and data telemetry. Lack of enough information on many physiological processes such as human speech production dynamics has hindered research on bases of …

    rice Repository record for Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants (opens in a new tab)

  12. Temperature regulation post hemorrhagic shock in rats : atheoretical analysis

    … supplied by a 915 MHZ microwave generator. The specific absorption rate (SAR) resulting from this power level was calculated to be 1.4W/Kg.</p><p>The animals that were rewarmed after resuscitation showed a significantly higher long term survival (100%) than non-heated animals (62.5%). These high …

    njit Repository record for Temperature regulation post hemorrhagic shock in rats : atheoretical analysis (opens in a new tab)

  13. SYNTHESIS AND CHARACTERIZATION OF MAGNETIC METAL OXIDE (Fe3O4, Gd2O3) NANOPARTICLES AND THEIR THERANOSTIC APPLICATIONS.

    … The 30 nm Fe3O4 nanoparticles show a high Specific Absorption Rate (SAR) value of almost 1700 W/g. Among the different shapes of 20 nm Fe3O4 nanoparticles, nanotretragons show a high SAR value of 1800 W/g. CoFe2O4 nanoparticles of size 15 nm exhibit a SAR value of 885 W/g. We tried to …

    nus Repository record for SYNTHESIS AND CHARACTERIZATION OF MAGNETIC METAL OXIDE (Fe3O4, Gd2O3) NANOPARTICLES AND THEIR THERANOSTIC APPLICATIONS. (opens in a new tab) Download file for SYNTHESIS AND CHARACTERIZATION OF MAGNETIC METAL OXIDE (Fe3O4, Gd2O3) NANOPARTICLES AND THEIR THERANOSTIC APPLICATIONS. (opens in a new tab)

  14. A Study of Fe<sub>3</sub>O<sub>4</sub> Magnetic Nanoparticle RF Heating in Gellan Gum Polymer Under Various Experimental Conditions for Potential Application in Drug Delivery

    … physical properties, such as the ability to generate heat in response to an alternating magnetic field, make these structures ideal for such purposes. This study's objective was to elucidate the mechanisms primarily responsible for RF MNP heating and determine how such processes affect polymer …

    usf Repository record for A Study of Fe<sub>3</sub>O<sub>4</sub> Magnetic Nanoparticle RF Heating in Gellan Gum Polymer Under Various Experimental Conditions for Potential Application in Drug Delivery (opens in a new tab)

  15. Noninvasive microwave technique for human cardiorespiratory hemodynamic assessments

    … of multiple vital signs including heart rate and breathing as well as the changes in lung water content from a single transmission and reflection coefficient measurement with an electromagnetic coupler. Using a short time Fourier Transform based DSP method, it is shown that these vital …

    hawaii Repository record for Noninvasive microwave technique for human cardiorespiratory hemodynamic assessments (opens in a new tab)

  16. User Equipment antenna design for Non- Terrestrial Network communication

    … EMF compliance was evaluated in terms of specific absorption rate (SAR) in accordance with IEEE/IEC standards and the impact of increasing transmit power to 26 dBm was also assessed. Uplink link budget analysis was subsequently performed for all three antennas and benchmarked against an …

    chalmers Repository record for User Equipment antenna design for Non- Terrestrial Network communication (opens in a new tab)

  17. Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.

    … in actual experiments. In this thesis, we demonstrate the first successful implementation of parallel transmission at an ultrahigh field of 9.4 Tesla (T) in the human brain with an eight-channel transmit system, using accelerated (x 4) RF pulses designed to create arbitrarily shaped excitation …

    umn Repository record for Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System. (opens in a new tab)

  18. Artificial Magnetic Conductor Integrated Textile Monopole Antenna

    … inside the habitat. The antenna is integrated with artificial material known as High Impedance Surface (HIS) for performance enhancement. The purpose of the system is to constantly monitor vital signals of the astronauts. The entire design cycle of wearable Co-Planar Waveguide (CPW) fed …

    nodak Repository record for Artificial Magnetic Conductor Integrated Textile Monopole Antenna (opens in a new tab)

  19. Enhanced Microwave Hyperthermia using Nanoparticles

    … the nanoparticles allow the electromagnetic absorption to be focused in the tumor and can be used to treat deep tumors in organs, such as the liver. Iron oxide magnetic nanoparticles were considered for this study as they are non-toxic and bio-compatible. For the case of breast cancer, the …

    ucf Repository record for Enhanced Microwave Hyperthermia using Nanoparticles (opens in a new tab)

Page 1 of 5