Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 143 for “"Specific absorption rate - SAR"”

  1. SMALL SIZE COUPLING FEED AND INDUCTIVE SHORTING ANTENNA FOR WIDE BANDWIDTH, INCREASED GAIN AND EFFICIENCY WITH LOW SPECIFIC ABSORPTION RATE (SAR) OPERATION

    … Modern cellular phone should be capable to operate in wide range of frequency spectrum for their global access to provide end user customers these communication services. Hence mobile antennas should be designed in such a way that they should generate wideband operation. But commercially …

    mtu Repository record for SMALL SIZE COUPLING FEED AND INDUCTIVE SHORTING ANTENNA FOR WIDE BANDWIDTH, INCREASED GAIN AND EFFICIENCY WITH LOW SPECIFIC ABSORPTION RATE (SAR) OPERATION (opens in a new tab)

  2. MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATIONS

    … magnetic resonance imaging (MRI) contrast and specific absorption rate (SAR) properties. In vitro experiments have demonstrated high cellular uptake and low cytotoxicity and the AC magnetic field heating experiments showed effectiveness in temperature rise and 60-74% cancer cell death due to …

    nus Repository record for MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATIONS (opens in a new tab)

  3. Specific absorption rate calculations using finite difference time domain method

    … truncated by a Perfectly Matched Layer (PML). Specific Absorption Rate (SAR) calculations have been carried out to study safety issues in mobile communication.

    metu Repository record for Specific absorption rate calculations using finite difference time domain method (opens in a new tab)

  4. Analysis of wireless power transfer efficiency and specific absorption rate for a distributed brain implant system.

    … power transfer (WPT) efficiency and reducing the specific absorption rate (SAR) will be crucial for its clinical success. Towards these goals, we present an EM simulation method, a lumped equivalent circuit model, and a theoretical analysis to accurately predict the power delivered to the …

    baylor Repository record for Analysis of wireless power transfer efficiency and specific absorption rate for a distributed brain implant system. (opens in a new tab)

  5. Radio frequency power absorption in a human model with pacemakers in MRI

    … with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker …

    uvic Repository record for Radio frequency power absorption in a human model with pacemakers in MRI (opens in a new tab)

  6. Finite-difference time-domain analysis of microwave heart monitoring

    … to analyze the induced current distribution and specific-absorption rate (SAR) using the finite-difference time-domain (FDTD) method on an accurate two-dimensional thoracic model provided by the Visual Human Project (VHP). Additional test cases are analyzed which model the two-dimensional heart …

    mcgill Repository record for Finite-difference time-domain analysis of microwave heart monitoring (opens in a new tab)

  7. Orientation-dependent adaptive antenna for low earth orbit satellite communications

    … power makes it difficult for the device to meet specific absorption rate (SAR) restrictions. An adaptive beam forming technique for shaping radiation away from the user’s head is proposed. This technique uses a back-to-back patch antenna design with an impedance monitoring based system capable of …

    manitoba Repository record for Orientation-dependent adaptive antenna for low earth orbit satellite communications (opens in a new tab)

  8. DEVELOPMENT OF NOVEL PULSE SEQUENCES FOR MAGNETIC RESONANCE FINGERPRINTING

    … Echo Split NMR technique (QUEST) to reduce the Specific Absorption Rate (SAR), the Fast Imaging with Steady-state Precession (FISP) to improve the performance with off-resonance, the Double Echo Steady-state (DESS) to quantify diffusion, and a Simultaneous MultiSlice (SMS) MRF to further reduce …

    ohiolink Repository record for DEVELOPMENT OF NOVEL PULSE SEQUENCES FOR MAGNETIC RESONANCE FINGERPRINTING (opens in a new tab)

  9. Variable Rate Selective Excitation RF Pulse in MRI

    … Radio Frequency (RF) pulses. A Variable Rate Selective Excitation (VERSE) pulse is a type of RF pulse that reduces the Specific Absorption Rate (SAR) of molecules in a specimen while preserving its duration and slice profile. SAR was designed to be minimized by the VERSE pulse as it leads …

    mcmaster Repository record for Variable Rate Selective Excitation RF Pulse in MRI (opens in a new tab)

  10. The Electromagnetic Simulation of Birdcage Coils for MRI based on Finite Element Method

    … as the frequency increases. Therefore, to accurately determine the capacitance, we use frequency domain analysis method for both the low-pass and high-pass birdcage coils in COMSOL Multiphysics. Modeling the birdcage coil in a 3D simulation environment helps to analyze the electromagnetic field …

    ohiolink Repository record for The Electromagnetic Simulation of Birdcage Coils for MRI based on Finite Element Method (opens in a new tab)

  11. CURIE TEMPERATURE MEASUREMENT OF FERROMAGNETIC NANOPARTICLES BY USING CALORIMETRY

    … performance of nanoparticles was described by Specific Absorption Rate (SAR). Heating and cooling rate were also calculated as a function of time and relationship of the rates to the temperature of magnetic nanoparticle was established. Based on linear fits of these rates, an extrapolation to …

    ohiolink Repository record for CURIE TEMPERATURE MEASUREMENT OF FERROMAGNETIC NANOPARTICLES BY USING CALORIMETRY (opens in a new tab)

  12. IDENTIFICATION OF Cav 3.2 T-TYPE VOLTAGE GATED CALCIUM CHANNELS AS KEY MEDIATORS OF TARGETED INHIBITION OF HEPATOCELLULAR CARCINOMA BY AMPLITUDE-MODULATED RADIOFREQUENCY ELECTROMAGNETIC FIELDS

    … mechanism of action w e have a ssessed the Specific Absorption Rate (SAR) level and dis tribution inside the human body . Additionally, we performed various i n vitro and in vivo experiments that were exposed to HCC - specific AM RF EMF using systems replicating human exposure levels and …

    wfu Repository record for IDENTIFICATION OF Cav 3.2 T-TYPE VOLTAGE GATED CALCIUM CHANNELS AS KEY MEDIATORS OF TARGETED INHIBITION OF HEPATOCELLULAR CARCINOMA BY AMPLITUDE-MODULATED RADIOFREQUENCY ELECTROMAGNETIC FIELDS (opens in a new tab)

  13. Safety assessment of microwave radar breast imaging in the 0.434-9 GHz range

    … surface, allowing low-power microwaves to penetrate through the tissue with a loss that is acceptably low to permit for a radar-like detection approach. While this imaging modality is relatively new, and a few prototypes have been reported, not many publications consider its safety. This work …

    mcgill Repository record for Safety assessment of microwave radar breast imaging in the 0.434-9 GHz range (opens in a new tab)

  14. Miniaturised Implantable Antenna for Wireless Capsule Endoscopy

    … Simulation and measurement results demonstrate strong alignment. The study emphasises the necessity of an omnidirectional radiation pattern to ensure reliable communication regardless of the capsule’s rotation within the GI tract. To ensure patient safety, specific absorption rate (SAR) …

    durham Repository record for Miniaturised Implantable Antenna for Wireless Capsule Endoscopy (opens in a new tab)

  15. Modeling and calculation of the specific absorption rate for multi-antenna mobile devices

    … the human exposure to the RF radiation, the specific absorption rate (SAR) is introduced as a measure. Regulatory agencies have standards limiting the maximum SAR to ensure safety. In order to comply with the regulations, the SAR induced in the human head and body should be evaluated by …

    uiuc Repository record for Modeling and calculation of the specific absorption rate for multi-antenna mobile devices (opens in a new tab)

  16. Precise SAR Measurements In The Near-Field of RF Antenna Systems

    Wireless devices must meet specific safety radiation limits, and in order to assess the health affects of such devices, standard procedures are used in which standard phantoms, tissue-equivalent liquids, and miniature electric field probes are used. The accuracy of such measurements depend on the …

    maryland Repository record for Precise SAR Measurements In The Near-Field of RF Antenna Systems (opens in a new tab)

  17. Uncertainty in computational RF dosimetry

    … (RF) electromagnetic field dosimetry studies the absorption of electromagnetic energy inside the human body. The absorbed energy is measured in terms of the specific absorption rate (SAR), which is linked to the possible adverse thermal effects of the exposure to RF electromagnetic fields. With …

    aalto Repository record for Uncertainty in computational RF dosimetry (opens in a new tab)

  18. Redução de taxa de absorção específica em phantoms de tecidos humanos por meio de superfícies seletivas em frequência com substratos feitos de têxteis hospitalares

    This work proposes an integrated antenna with frequency selective surface (FSS) with textile substrate for applications in medical continuous monitoring systems with reduced specific absorption rate (SAR). The antenna and FSS were fabricated on cotton and polyester textile substrates, used in …

    brazil-ufrn Repository record for Redução de taxa de absorção específica em phantoms de tecidos humanos por meio de superfícies seletivas em frequência com substratos feitos de têxteis hospitalares (opens in a new tab)

  19. Temperature regulation post hemorrhagic shock in rats : atheoretical analysis

    … supplied by a 915 MHZ microwave generator. The specific absorption rate (SAR) resulting from this power level was calculated to be 1.4W/Kg.</p><p>The animals that were rewarmed after resuscitation showed a significantly higher long term survival (100%) than non-heated animals (62.5%). These high …

    njit Repository record for Temperature regulation post hemorrhagic shock in rats : atheoretical analysis (opens in a new tab)

  20. Optimization of the measurement sequence used for functional Fourier Decomposition Magnetic Resonance Imaging of the human lung at 1.5 Tesla

    … restriction of the utilized flip angles, due to specific absorption rate (SAR) limitations. To achieve the necessary improvements, advanced techniques were used, specifically, (utra-)fast bSSFP, two speed variablerate selective excitation (VERSE) pulses and variable flip angle (VFA) patterns. All …

    heid-diss Repository record for Optimization of the measurement sequence used for functional Fourier Decomposition Magnetic Resonance Imaging of the human lung at 1.5 Tesla (opens in a new tab)

Page 1 of 8