Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 129 for “"Specimen preparation"”.

  1. Laboratory specimen preparation for cold recycled asphalt

    … aims at finding a method for laboratory sample preparation for cold recycled asphalt which will produce specimens, in the shortest time, having properties similar to those of material laid in the field. In Phase One of the testing procedure the amount of new binder needed and the target …

    vu-aus Download PDF for Laboratory specimen preparation for cold recycled asphalt (opens in a new tab)

  2. In-situ atom probe specimen preparation with a planar region of interest

    Techniques for rapid preparation of atom probe specimens extracted from the surface of a bulk crystal sample are further developed with regards to samples having a planar region of interest. An atom probe specimen is a needle-shaped structure several microns long and approximately 100 nm in …

    colo-mines Repository record for In-situ atom probe specimen preparation with a planar region of interest (opens in a new tab)

  3. The effect of specimen preparation on degree of conversion and hardness of dental resin composites

    … J/cm\(^2\); radiant exposure). A total of 72 specimens were prepared and divided into two main groups (Figure 2.1). Lower surfaces of specimens were characterized using surface microhardness measurements (Vickers Hardness; Duramin Struers, ver. 0.04; 9.807 N, 15 s), and by two methods of …

    birmingham Download PDF for The effect of specimen preparation on degree of conversion and hardness of dental resin composites (opens in a new tab)

  4. Transmission Electron Microscope Specimen Preparation Techniques for Studies of Surface Plasmon Resonance Bio-sensing Detectors Based on Nanostructured TiO2 and Au Bilayer Films

    … using both plan view and cross section specimens. The first type of specimens provides an overview of the sample and information about the fine scale morphology of the small holes. The second type reveals the structure of the different interfaces of the detector multilayers. The TEM …

    chalmers Repository record for Transmission Electron Microscope Specimen Preparation Techniques for Studies of Surface Plasmon Resonance Bio-sensing Detectors Based on Nanostructured TiO2 and Au Bilayer Films (opens in a new tab)

  5. Studying the atomic structure of an electron beam sensitive catalyst

    … electron microscopy (STEM) imaging. Proper specimen preparation is one of the most important factors in order to achieve high-resolution. A substantial part of this work therefore concerns the study how to optimally prepare SSZ-13 samples for high-resolution imaging. Specifically, we try to …

    chalmers Repository record for Studying the atomic structure of an electron beam sensitive catalyst (opens in a new tab)

  6. Liquefaction Behaviour of Pond Ash under Monotonic and Cyclic Loading

    … tests. In order to investigate the effect of specimen preparation method, moist tamping (MT) and paste deposition (PD) specimens were employed. The latter was developed to simulate wet disposal of pond ash in ash ponds. Both original and re-used materials were used to re-constitute specimens. …

    unsw Repository record for Liquefaction Behaviour of Pond Ash under Monotonic and Cyclic Loading (opens in a new tab)

  7. An Automated System for Cryo-Electron Microscopy Sample Preparation

    … through more traditional imaging methods. The preparation of samples for cryo-electron microscopy studies is currently a labor and time intensive process. Samples must be applied to an imaging substrate under tightly controlled environmental conditions, formed into a thin film, vitrified with …

    rice Repository record for An Automated System for Cryo-Electron Microscopy Sample Preparation (opens in a new tab)

  8. Investigation of the rejuvenator content effect on the mechanical characteristics of cold recycled asphalt mixes

    … employment of rejuvenators in different cold mix preparation scenarios. To do so the effect of rejuvenator content in different aspects of asphalt rehabilitation including clustering effect, and rheological characterization of the cold mixes were examined in different conditions of specimen …

    ets-quebec Download PDF for Investigation of the rejuvenator content effect on the mechanical characteristics of cold recycled asphalt mixes (opens in a new tab)

  9. Comparison of Two Loading Surface Preparation Methods on Rat Vertebral Bodies for Compression Testing

    … shape of rat vertebral bodies requires some specimen preparation to create two parallel loading surfaces for uniaxial compression testing. Two specimen preparation methods are reported in the current body of literature. One cuts the cranial and caudal surfaces to make them parallel to each …

    queens Repository record for Comparison of Two Loading Surface Preparation Methods on Rat Vertebral Bodies for Compression Testing (opens in a new tab)

  10. Factors affecting the fracture energy of a structural adhesive

    … sensitivity of the strain energy release rate·to specimen preparation. The rate and time dependence of the adhesive were then investigated using the TDGB specimen. The fractured surfaces were also studied using scanning electron microscopy to determine the mechanisms of failure.

    vt Repository record for Factors affecting the fracture energy of a structural adhesive (opens in a new tab)

  11. Preparation of a Thin Specimen of Rutile for Transmission Electron Microscopy

    … but this method is not suitable for the preparation of metal oxide specimens. This research was undertaken with the intention to develop a specimen preparation technique and to observe the imperfections, such as dislocations and stacking faults in single crystal rutile.

    marquette Repository record for Preparation of a Thin Specimen of Rutile for Transmission Electron Microscopy (opens in a new tab)

  12. Microstructural characterisation of epitaxial rare earth metal based films

    … the misfit dislocation network. Conventional TEM specimen preparation techniques were inappropriate for the preparation of metallic foils, and so appropriate specimen preparation techniques were developed. HREM was used to characterise the strain relief mechanisms within a partially relaxed …

    oxford Repository record for Microstructural characterisation of epitaxial rare earth metal based films (opens in a new tab)

  13. Quantifying non-axial deformations in rat myocardium

    … affinity. A set of protocols was established for specimen preparation, image acquisition, and analysis, and two experiments were performed according to these methods. Results indicate that myocyte deformations are non-affine; therefore, some cellular rearrangement must occur when myocardium is …

    tamu Repository record for Quantifying non-axial deformations in rat myocardium (opens in a new tab)

  14. Monotonic and cyclic shear response of reconstituted natural silt

    A triaxial apparatus was upgraded and a specimen preparation device was developed to enable monotonic and cyclic triaxial testing of low plastic reconstituted silts. The silt reconstitution technique involves consolidating silt slurry inside a cylindrical split mold, directly on the triaxial base …

    ubc Repository record for Monotonic and cyclic shear response of reconstituted natural silt (opens in a new tab) Download PDF for Monotonic and cyclic shear response of reconstituted natural silt (opens in a new tab)

  15. Cyclic Triaxial Testing to Evaluate Factors Affecting The Unsaturated Cyclic Behavior of a Silty Sand

    … conducted, which varied wetting and drying path specimen preparation techniques, initial matric suction, initial net normal stress, and cyclic stress ratio. Specimens prepared using the wetting path experienced significantly higher cyclic resistance than those prepared using the drying path. …

    south-carolina Repository record for Cyclic Triaxial Testing to Evaluate Factors Affecting The Unsaturated Cyclic Behavior of a Silty Sand (opens in a new tab)

  16. Effect of soil type and compaction methods on the confined stiffness of soil-geogrid composites

    … method on the K_{SGC} of geogrids. Accordingly, specimens were tested in the SGI setup at multiple density levels using aggregates of different angularity and grain sizes. In addition, the effect of the compaction method on the results was investigated with specimens prepared using the existing …

    texas Repository record for Effect of soil type and compaction methods on the confined stiffness of soil-geogrid composites (opens in a new tab)

  17. Evaluation of Uncertainty for Soil Water Characteristic Curve Measurements and Implications for Predicting the Hydro-mechanical Behavior of Unsaturated Soils

    … SWCC parameter variability. Variability of inter-specimen SWCC measurements was quantified for six soil samples. The hanging column method, an evaporation method with the UMS HYPROP apparatus, and the dew point potentiometer method provided measurement of discrete SWCC data. The van Genuchten SWCC …

    unr Repository record for Evaluation of Uncertainty for Soil Water Characteristic Curve Measurements and Implications for Predicting the Hydro-mechanical Behavior of Unsaturated Soils (opens in a new tab)

  18. Elastic and viscoelastic characterization of transversely isotropic composite laminae

    … properties present difficulties related to specimen preparation, fixturing and test apparatus. Consequently, engineers frequently make use of micromechanics generated properties. Unfortunately, micromechanics approaches do not usually account for manufacturing and temperature variations, …

    colostate Repository record for Elastic and viscoelastic characterization of transversely isotropic composite laminae (opens in a new tab)

  19. Considerações sobre ensaios triaxiais em areias

    … tests on sands. A study of a new method of specimen preparation using pluviation, where the unit weight of the sample can be previously specified, is also presented. ln addition, a simplified saturation technique in which the specimens were submitted, outside the triaxial cell, to a low …

    brazil-uerj Repository record for Considerações sobre ensaios triaxiais em areias (opens in a new tab)

Page 1 of 7