Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 117 for “"Spectral domain optical coherence tomography"”

  1. Functional Spectral Domain Optical Coherence Tomography Imaging

    <p>Spectral Domain Optical Coherence Tomography (SDOCT) is a high-speed, high resolution imaging modality capable of structural and functional resolution of tissue microstructure. SDOCT fills a niche between histology and ultrasound imaging, providing non-contact, non-invasive backscattering …

    duke Repository record for Functional Spectral Domain Optical Coherence Tomography Imaging (opens in a new tab)

  2. COMPRESSIVE SENSING FOR SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY

    Spectral domain optical coherence tomography (SD OCT) imaging with high axial resolution and a large imaging depth requires a large number of sampling points in the spectral domain. This requires a high-resolution spectrometer with a large linear array camera which leads to a large amount of …

    jhu Repository record for COMPRESSIVE SENSING FOR SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY (opens in a new tab)

  3. Ultrahigh-resolution, deep-penetration spectral-domain optical coherence tomography

    Optical coherence tomography (OCT) is a label-free optical imaging modality that allows non-invasive in-depth visualization of microscopic structures in samples. With a typical resolution of 10-15 [mu]m and a penetration of up to a few mm, OCT is widely used for medical diagnoses in fields such as …

    mit Repository record for Ultrahigh-resolution, deep-penetration spectral-domain optical coherence tomography (opens in a new tab)

  4. 400 kHz Spectral Domain Optical Coherence Tomography for Corneal Imaging

    … the help of high speed and ultra-high resolution optical coherence tomography (UHR-OCT) corneal imaging can improve the early diagnostics of corneal diseases and well as monitoring the effectiveness of different therapies such as surgical intervention or administration of pharmaceutical drugs. The …

    waterloo Repository record for 400 kHz Spectral Domain Optical Coherence Tomography for Corneal Imaging (opens in a new tab)

  5. Reflective optics-based line-scanning spectral domain optical coherence tomography system

    Optical Coherence Tomography (OCT) is a high-resolution non-invasive and non-contact imaging technology. Traditionally, multi-axis spot-focused scanning is used for transverse scanning to obtain a two or three-dimensional OCT image. This increases the time to acquire an image and imaging …

    concordia

  6. Line-Field Spectral Domain Optical Coherence Tomography: Design and Biomedical Applications

    … progression and potentially for disease cure. Optical coherence tomography (OCT), often described as the optical equivalent of ultrasound imaging, enables high-speed, non-invasive volumetric imaging at a cellular resolution. These advantages of OCT have made it a useful tool in ophthalmology …

    waterloo Repository record for Line-Field Spectral Domain Optical Coherence Tomography: Design and Biomedical Applications (opens in a new tab)

  7. In Vivo Newt Lens Regeneration Monitoring with Spectral-Domain Optical Coherence Tomography

    … only. For the first time, we demonstrate that Optical Coherence Tomography (SD-OCT) can capture the in vivo essential morphological characteristics with abundant dynamic features. Monitoring lens regeneration using a single newt is now possible. The results show that the lens originates below …

    ohiolink Repository record for In Vivo Newt Lens Regeneration Monitoring with Spectral-Domain Optical Coherence Tomography (opens in a new tab)

  8. Development of spectral domain optical coherence tomography for pharmaceutical and medical application

    Spectral-domain optical coherence tomography (SD-OCT) is a type of non-destructive imaging technique that is capable of resolving the inner structure of a sample with micrometre spatial resolution. SD-OCT is based on low coherence interferometry. It utilises a spectrometer to grab the spectral …

    liverpool Repository record for Development of spectral domain optical coherence tomography for pharmaceutical and medical application (opens in a new tab)

  9. Spectral Domain Optical Coherence Tomography System Development for in Vivo Ophthalmic Imaging

    <p>Spectral‐domain optical‐coherence tomography (SDOCT) has recently emerged as a powerful new tool for noninvasive human retinal imaging. I have developed a low‐cost, high resolution real‐time Spectral Domain Optical Coherence Tomography (SDOCT) system optimized for rapid 3D imaging of the human …

    duke Repository record for Spectral Domain Optical Coherence Tomography System Development for in Vivo Ophthalmic Imaging (opens in a new tab)

  10. Low-cost and digital refocusing approaches to high-resolution spectral-domain optical coherence tomography

    … and diagnosis of human diseases. High-resolution optical coherence tomography (OCT), including but not limited to ultrahigh-resolution OCT (UHR OCT) and micro-OCT (µOCT), are particularly suitable for this purpose owning to their superb spatial resolutions. However, technical difficulties have to …

    nanyang Repository record for Low-cost and digital refocusing approaches to high-resolution spectral-domain optical coherence tomography (opens in a new tab)

  11. Spectral domain optical coherence tomography system design : sensitivity fall-off and processing speed enhancement

    Spectral domain optical coherence tomography (SD-OCT) is an imaging modality that provides cross-sectional images with micrometer resolution. One major drawback of SD-OCT, however, is the depth dependent sensitivity fall-off by which image quality rapidly degrades in regions corresponding to deeper …

    ubc Repository record for Spectral domain optical coherence tomography system design : sensitivity fall-off and processing speed enhancement (opens in a new tab)

  12. Imaging and vibrometry of the mouse cochlear apex using spectral domain optical coherence tomography

    … such as magnetic resonance imaging and computed tomography do not have the necessary resolution to detect such changes and, furthermore, provide no functional information. As well, research into how the intracochlear tissues vibrate and thus transduce sound pressure waves into neural signals has …

    rice Repository record for Imaging and vibrometry of the mouse cochlear apex using spectral domain optical coherence tomography (opens in a new tab)

  13. Methodologies for Analyzing Retinal Nerve Fiber Layer Thickness/Area Using Spectral Domain Optical Coherence Tomography.

    … within the eye. With technologies such as spectral domain optical coherence tomography (SD OCT), the RNFL thickness can be quantified with resolutions approaching 5 µm. Although these measures have been shown to be reliable, the accuracy of thickness measures is related to ocular biometry …

    houston Repository record for Methodologies for Analyzing Retinal Nerve Fiber Layer Thickness/Area Using Spectral Domain Optical Coherence Tomography. (opens in a new tab)

  14. The apply of spectral domain optical coherence tomography in retinal vessel assessment of diabetic retinopathy

    Purpose: To evaluate spectral domain optical coherence tomography (SD-OCT) based methods to differentiate retinal vessel types and easure retinal vessel diameters, and compare these findings with the reference from infrared reflectance (IR) images and/or fluorescein angiography (FA); then, evaluate …

    fu-berlin Repository record for The apply of spectral domain optical coherence tomography in retinal vessel assessment of diabetic retinopathy (opens in a new tab)

  15. Novel segmentation algorithm for high-throughput analysis of spectral domain-optical coherence tomography imaging of teleost retina

    Aim Spectral Domain-Optical Coherence Tomography (SD-OCT) has become an essential tool to assess the health of ocular tissues in live subjects. The processing of SD-OCT images, in particular from non-mammalian species, is a labour-intensive manual process due to the lack of access to analytical …

    newfoundland Repository record for Novel segmentation algorithm for high-throughput analysis of spectral domain-optical coherence tomography imaging of teleost retina (opens in a new tab)

  16. Line-Scan Spectral-Domain Optical Coherence Tomography for Cellular Resolution Structural and Vascular Imaging of Biological Tissues

    Optical coherence tomography (OCT) is an optical interferometric technique for non-invasive contactless imaging of the cellular-level structures of biological tissues. However, the application of OCT for in-vivo volumetric cellular resolution imaging of the human anterior eye is challenging due to …

    waterloo Repository record for Line-Scan Spectral-Domain Optical Coherence Tomography for Cellular Resolution Structural and Vascular Imaging of Biological Tissues (opens in a new tab)

  17. Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues

    A line-scan spectral-domain optical coherence tomography system was developed for corneal imaging. It utilizes a Powell lens to achieve a better line illumination power distribution than the conventional use of cylindrical lenses. It achieves a lateral resolution of <2.1 microns and ~4.1 microns in …

    waterloo Repository record for Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues (opens in a new tab)

Page 1 of 6