Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Spectral match"”.

  1. Design and Validation of an LED-Based Solar Simulator for Solar Cell and Thermal Testing

    … main criteria were identified as design goals - spectral match ratio, spatial non-uniformity, and temporal instability. An electrical design for an LED-based simulator to satisfy these criteria was developed and implemented, making use of existing lab equipment where possible to minimize cost. …

    calpoly Repository record for Design and Validation of an LED-Based Solar Simulator for Solar Cell and Thermal Testing (opens in a new tab)

  2. Novel Relative Spontaneous Ignition Temperature Determination Using Carbon Dioxide Onset with STA/IR

    … of carbon dioxide was successful with a spectral match of 90.2 percent and further used in the determination of relative spontaneous ignition temperature, or RSIT. The RSIT value during the growing season for Chinese tallow, Chinese tallow stem, Chinese privet, and Yaupon were 208.4°C, …

    sfasu Repository record for Novel Relative Spontaneous Ignition Temperature Determination Using Carbon Dioxide Onset with STA/IR (opens in a new tab)

  3. Molecular cloning and characterization of sesquiterpene synthases from valeriana officinalis

    … C/D, and drimenol, respectively, based on the spectral match in the mass spectrometry library. Additional structural analyses using GC-MS and 13C-NMR spectrometry in comparison to a semi-synthesized standard confirmed the chemical identity of valerena-4,7(11)-diene. This is the first report of …

    calgary Repository record for Molecular cloning and characterization of sesquiterpene synthases from valeriana officinalis (opens in a new tab)

  4. Development of LED-based instrumentation for the monitoring of water quality parameters

    … tests for water quality monitoring coincide spectrally with widely available LED sources. Existing monitors use incandescent filament-based sources combined with narrow-band interference filters. Such systems suffer from problems of stability, bulk, cost and degradation with time. The …

    dcu Download PDF for Development of LED-based instrumentation for the monitoring of water quality parameters (opens in a new tab)

  5. Synthesis, Characterization and Application of Luminescent Quantum Dots and Microcrystalline Phosphors

    … fast decay, low afterglow and an improved spectral match to the CCD detector, indicated that ZnTe:O is a promising phosphor candidate for x-ray imaging applications.

    gatech Repository record for Synthesis, Characterization and Application of Luminescent Quantum Dots and Microcrystalline Phosphors (opens in a new tab)

  6. Nanowindow: Measuring Window Performance and Energy Production of a Nanofluid Filled Window

    … 750–850 W/m2, and resulted in an undefined spectral match, Class B spatial uniformity, and Class B temporal stability. All Nanowindows were tested in a calibrated hot box determined to have a ±4% degree of accuracy based on four laboratory samples establishing a framework to conduct U-factor …

    oregon Repository record for Nanowindow: Measuring Window Performance and Energy Production of a Nanofluid Filled Window (opens in a new tab)

  7. Phenazine: A Building Block for Multinuclear and Heterometallic Complexes, Where the Ligand Acts as an Electron Acceptor and Radical Abstractor

    … efficient conversion of solar energy is the good spectral match of the sensitizer absorption to the emission spectrum of solar radiation. In this regard, the ruthenium sensitizers’ spectral response in the lower energy regions is not sufficient. The current project has three parts. In the first …

    ottawa-retro Repository record for Phenazine: A Building Block for Multinuclear and Heterometallic Complexes, Where the Ligand Acts as an Electron Acceptor and Radical Abstractor (opens in a new tab)

  8. Spectrally-matched neutron detectors designed using computational adjoint S<sub>N for plug-in replacement of Helium-3

    … rates that are sufficient, because the neutron spectral response is essentially irrelevant. However, in applications such as safeguards, non-proliferation efforts, and material control and accountability programs (MC&A), a failure to use detectors that are spectrally matched to 3He can …

    gatech Repository record for Spectrally-matched neutron detectors designed using computational adjoint S<sub>N for plug-in replacement of Helium-3 (opens in a new tab)

  9. Internal pressure in low and medium rise buildings subjected to high winds

    … Calibration of loss coefficients by the way of a spectral match between the measured and predicted spectra resulted in values ranging from 6 to 36 with increase in opening size. Investigations into the effects of envelope flexibility in a building with an opening are conducted using a generalized …

    auckland-ms Repository record for Internal pressure in low and medium rise buildings subjected to high winds (opens in a new tab)