Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 8 of 8 for “"Spectrometric detector"”

  1. Quantification of Tylosin Antibiotics in Cattle Waste

    … Varian 212-LC HPLC and Agilent 500 Ion Trap mass spectrometric detector. The concentrations of tylosin in study group animals were compared with respect to the date of sampling and cattle body weight with a control group and results are presented.

    wku-diss Repository record for Quantification of Tylosin Antibiotics in Cattle Waste (opens in a new tab)

  2. Determination of dapsone and its metabolites

    … of DDS, MAD and DAD using HPLC with a uv detector and/or a mass spectrometric detector. The HPLC was operated at 1 m1/min at 285 nm, using a C-18 reversed-phase column (AXXI CHROM, 5 micron, 25cm x 2.1mm). The isochratic mobile phase consisted of 67% aqueous pH 6 phosphate buffer, 23% …

    u-pacific Repository record for Determination of dapsone and its metabolites (opens in a new tab)

  3. Παραλαβή, ανάλυση με χρωματογραφικές μεθόδους και αντιμικροβιακή δράση ενώσεων του βακτηρίου Pseudomonas fluorescens X

    … atmospheric pressure chemical ionization-mass spectrometric detector (APCI-MSD) suggested that they are probably antibiotics due to their low molecular weight. Chemical structure was also analyzed by LC-MS/MS analysis, GC-MS analysis, Fourier Transform-IR analysis and Nuclear Magnetic …

    greece Repository record for Παραλαβή, ανάλυση με χρωματογραφικές μεθόδους και αντιμικροβιακή δράση ενώσεων του βακτηρίου Pseudomonas fluorescens X (opens in a new tab)

  4. Development of novel extraction and separation methods for the determination of anthracyclines and taxanes simultaneously from biological matrices

    … and this method was then transferred to a mass spectrometric detector for more sensitive monitoring of the drugs. The on-line SPE-LC-MS assay did result in lower limits of detection and was fully automated. The entire method of extraction, separation and detection was achieved on-line by …

    dcu Repository record for Development of novel extraction and separation methods for the determination of anthracyclines and taxanes simultaneously from biological matrices (opens in a new tab)

  5. HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC SEPARATION COUPLED TO INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR ELEMENTAL SPECIATION IN ENVIRONMENTAL SAMPLES

    … to an inductively coupled plasma mass spectrometric detector was developed for separation and identification of cadmium-phytochelatin species. The method was applied to investigate long distance root to shoot transport of cadmium chaperoned by phytochelatins in genetically modified …

    ohiolink Repository record for HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC SEPARATION COUPLED TO INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR ELEMENTAL SPECIATION IN ENVIRONMENTAL SAMPLES (opens in a new tab)

  6. EVOLUCIÓN DE LOS RESIDUOS DE PLAGUICIDAS EN FRUTAS CÍTRICAS FRESCAS. INCIDENCIA SOBRE LOS ACEITES ESENCIALES

    … the gas chromatography technique with mass spectrometric detector type simple quadrupole (GC-MS), was used for quantification of chlorpyrifos and prochloraz, while for carbendazim and thiabendazole quantification, liquid chromatography/tandem mass spectrometry detection (triple quadrupole) …

    upv Repository record for EVOLUCIÓN DE LOS RESIDUOS DE PLAGUICIDAS EN FRUTAS CÍTRICAS FRESCAS. INCIDENCIA SOBRE LOS ACEITES ESENCIALES (opens in a new tab)

  7. Chemical and functional analyses of the plant cuticle as leaf transpiration barrier

    … by gas chromatography with a flame ionisation detector and a mass spectrometric detector, respectively. A high accumulation of pentacyclic triterpenoids as cuticular wax components in relation to the cutin monomer coverage was detected for Nerium oleander and for Rhazya stricta leaves, too. …

    wurz-thes Repository record for Chemical and functional analyses of the plant cuticle as leaf transpiration barrier (opens in a new tab)

  8. Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels

    La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les …

    star-france Repository record for Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels (opens in a new tab)