Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"Spinal fixation"”

  1. Posterior segmental spinal fixation in Scoliosis surgery

    Spinal deformity was recognised in the ancient works for philosophy, religion, myths, and fairy tales dating back as far as 3500BC[1,6]. Scoliosis was first described in the 5th century BC by Hippocrates. He recommended treatment with axial distraction on an extension apparatus (figure 1).

    cape-town Repository record for Posterior segmental spinal fixation in Scoliosis surgery (opens in a new tab)

  2. Design and biomechanical evaluation of a rodent spinal fixation device

    Previous experimental studies of spinal cord injury (SCI) in rodents established the importance of fixation of the spine in survival models following a mechanical injury. However, no fixation device has been designed to provide spinal stabilization, prevent additional damage to the cord, and …

    ubc Repository record for Design and biomechanical evaluation of a rodent spinal fixation device (opens in a new tab)

  3. A patient-specific approach for enhanced spinal fixation using a novel flexible pedicle screw

    Pedicle screw fixation has become the gold standard for spinal fixation surgery; however, current rigid pedicle screws are forced to fixate within a limited area. This limitation is driven by current rigid drilling instruments only being capable of drilling linear trajectories. This limited area of …

    texas Repository record for A patient-specific approach for enhanced spinal fixation using a novel flexible pedicle screw (opens in a new tab)

  4. Paauglių idiopatinės skoliozės chirurginės korekcijos metodų lyginamoji studija nustatant optimalų laikysenos prognostinį faktorių /

    Spinal fixation level is the most important assignment in Lenke I AIS surgery. Wrong fixation level can worsen patients posture and increases the probability of repeated operation. Patients were randomized into 3 groups according to the choice of spinal fusion level using „touched vertebra\" …

    vilnius Repository record for Paauglių idiopatinės skoliozės chirurginės korekcijos metodų lyginamoji studija nustatant optimalų laikysenos prognostinį faktorių / (opens in a new tab)

  5. Clinical and radiological prognostic factors in achieving a balanced correction in patients with Lenke type I AIS /

    Spinal fixation level is the most important assignment in Lenke I AIS surgery. Wrong fixation level can worsen patients posture and increases the probability of repeated operation. Patients were randomized into 3 groups according to the choice of spinal fusion level using „touched vertebra\" …

    vilnius Repository record for Clinical and radiological prognostic factors in achieving a balanced correction in patients with Lenke type I AIS / (opens in a new tab)

  6. Bending fatigue of cancellous bone screws used in anterior spine surgery.

    … been noted in early clinical results of anterior spinal fixation using standard 6.5mm outside diameter (3.2mm inside diameter) cancellous bone screws. Fractography was used to qualify and quantify the failure mode. Fracture mechanics was used to determine the load level from the fractographic …

    ottawa-retro Repository record for Bending fatigue of cancellous bone screws used in anterior spine surgery. (opens in a new tab)

  7. Proximal junctional kyphosis following surgical treatment of global sagittal imbalance : predictive analysis using mathematical and in vitro biomechanical models

    … Sagittal realignment using posterior spinal fixation and fusion, with or without corrective osteotomy, is the current treatment for global sagittal imbalance. Patients may develop proximal junctional kyphosis (PJK) through failure of the uppermost instrumented or adjacent vertebra. The …

    ubc Repository record for Proximal junctional kyphosis following surgical treatment of global sagittal imbalance : predictive analysis using mathematical and in vitro biomechanical models (opens in a new tab)

  8. A Keratin Biomaterial for Treatment Following Spinal Cord Hemisection Injury and Investigation of Secondary Damage Mechanisms

    Spinal cord injuries (SCI) are a severely debilitating injury that affects about 200,000 people in the United States alone. The only current treatment options include use of steroids, spinal fixation surgery, and rehabilitation, none of which provide any significant recovery of function. SCIs are …

    wfu Repository record for A Keratin Biomaterial for Treatment Following Spinal Cord Hemisection Injury and Investigation of Secondary Damage Mechanisms (opens in a new tab)

  9. Improvement of Ex Vivo Testing Methods for Spine Biomechanical Characterization

    … and biomechanical characterization of human spinal segments. The first was a literature review of existing testing methodology, the second examined common spine fixation procedures, and the third developed an improved fixation method. Spine biomechanical characterization is the primary …

    byu Repository record for Improvement of Ex Vivo Testing Methods for Spine Biomechanical Characterization (opens in a new tab)

  10. Osteoporotiniai slankstelių lūžiai. Klinikinių atvejų aprašymas ir literatūros apžvalga /

    … in 2019. After undergoing a segmental internal fixation and4 laminectomy, she experienced escalating pain and leg weakness. An intravertebral spacer (PEEK Cage implant) was inserted and improved her mobility. Patient did not seek further treatment. Case 2: A 66-year-old woman suffered a back …

    vilnius Repository record for Osteoporotiniai slankstelių lūžiai. Klinikinių atvejų aprašymas ir literatūros apžvalga / (opens in a new tab)

  11. IN VITRO BIOMECHANICAL TESTING AND COMPUTATIONALMODELING IN SPINE

    … following the implantation of two different spinal fixation devices; interspinous fixation device (ISD) and Hybrid dynamic stabilizers. ISD was evaluated as a stand-alone and in combination with unilateral pedicle rod system. The results were compared against the gold standard, spinal fusion …

    ohiolink Repository record for IN VITRO BIOMECHANICAL TESTING AND COMPUTATIONALMODELING IN SPINE (opens in a new tab)

  12. Study of biofunctionalized titanium implants on an osteoporotic animal model

    … Dental implants, joint prostheses, fracture fixation systems and spinal fixation systems are considered part of this group of devices. Therefore, its use is essential to ensure the well-being of the population. However, the increase in life expectancy in Europe and the United States, verified …

    barcelona Repository record for Study of biofunctionalized titanium implants on an osteoporotic animal model (opens in a new tab)

  13. Modelling the longer term effects of spinal burst fracture repair using vertebroplasty

    Burst fractures account for 15% of all spinal fractures and generally occur in the younger, more active generations. Traditional treatments of burst fractures can be highly invasive and may involve spinal fixation. Favourable short term results have been obtained when vertebroplasty has been used …

    whiterose Repository record for Modelling the longer term effects of spinal burst fracture repair using vertebroplasty (opens in a new tab)

  14. MRI RF-induced Heating Prediction for Complex-shaped Passive Implantable Devices using Neural Network Methods

    … complex-shaped PIMDs. Tibia Plating System and Spinal Fixation System device models are developed with variations on geometrical features. In-vitro and in-vivo EM simulations are performed with device mesh information and peak SAR values extracted. Incident Electric field information and mesh …

    houston Repository record for MRI RF-induced Heating Prediction for Complex-shaped Passive Implantable Devices using Neural Network Methods (opens in a new tab)

  15. Reduction of Dose Calculation Errors For Patients With Metal Implants Receiving Photon Radiation Therapy

    … in radiation oncology (hip prosthesis, spinal fixation rods, and dental fillings), and its dosimetric impact was evaluated using two clinical cases. Though not always the most successful method, O-MAR was the most consistent and thus safest candidate for all-purpose metal artifact …

    uthsc Repository record for Reduction of Dose Calculation Errors For Patients With Metal Implants Receiving Photon Radiation Therapy (opens in a new tab)

  16. Η εφαρμογή μη παρεμβατικής τεχνικής (Spinal Mouse) στην εκτίμηση της μετεγχειρητικής αποκατάστασης της σπονδυλικής στήλης

    … would be desirable. One such method is the Spinal Mouse. Although the reliability and the accuracy of the method, both between examiners and between measurements were assessed in previous studies, however they concerned only healthy population and children. Also, there is no study evaluating …

    greece Repository record for Η εφαρμογή μη παρεμβατικής τεχνικής (Spinal Mouse) στην εκτίμηση της μετεγχειρητικής αποκατάστασης της σπονδυλικής στήλης (opens in a new tab)

  17. Biomechanical Evaluation of Facet Bone Dowels in the Lumbar Spine

    … often involves a surgical fusion of the affected spinal segment. One method of fusing the spine is through modification of the zygapophyseal joint using facet bone dowels, however this method has not been fully researched. The current study looked at the effectiveness of these types of implants, …

    ohiolink Repository record for Biomechanical Evaluation of Facet Bone Dowels in the Lumbar Spine (opens in a new tab)

  18. Osteoporotic spine fixation : a biomechanical investigation

    … including trauma, deformity and degeneration. Spinal instrumentation is often used to stabilize the spinal column and help facilitate the fusion. The main problems of using spinal instrumentation in elderly patients (many with osteoporosis) are loss of fixation due to loosening and adjacent …

    ubc Repository record for Osteoporotic spine fixation : a biomechanical investigation (opens in a new tab)

  19. Biomechanics of Spine Following the Long Segment Fusions and various Surgical Techniques to reduce the Occurrence of Proximal Junction Kyphosis (PJK)

    … are well documented after long thoracolumbar spinal fusions. These fusions result in an abrupt load transition from a fused segment to a non-fused segment. Biomechanical testing has shown that the increased stiffness of the fused spinal segment increases loads and motion within adjacent …

    ohiolink Repository record for Biomechanics of Spine Following the Long Segment Fusions and various Surgical Techniques to reduce the Occurrence of Proximal Junction Kyphosis (PJK) (opens in a new tab)

Page 1 of 2